MegaRAID Storage Manager Application for Windows (17.05.01.02)
Dostępne sterowniki
MegaRAID Storage Manager Application for Windows (17.05.01.02)
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
change history
lsi-lnvgy_utl_msm_17.05.01.02_windows_x86-64.chg
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
readme
lsi-lnvgy_utl_msm_17.05.01.02_windows_x86-64.txt
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
MegaRAID Storage Manager Application for Windows (17.05.01.01)
lsi-lnvgy_utl_msm_17.05.01.02_windows_x86-64.zip
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
Opis
MegaRAID Storage Manager Application for Windows (17.05.01.02)
Co więcej
Zmień historię
MegaRAID Storage Manager Application Supported controllers: - N2226 SAS/SATA HBA for Lenovo System x (00AE916) - N2225 SAS/SATA HBA for Lenovo System x (00AE912) - N2215 SAS/SATA HBA for Lenovo System x (47C8676) - ServeRAID M5215 SAS/SATA Controller for Lenovo System x (46C9110) - ServeRAID M1210 SAS/SATA Controller for Lenovo System x - ServeRAID M1215 SAS/SATA Controller for Lenovo System x - ServeRAID M1210e SAS/SATA Controller for Lenovo System x - ServeRAID M5225 SAS/SATA Controller for Lenovo System x (00AE938) - ServeRAID M5225-2GB SAS/SATA Controller for Lenovo System x - N2125 SAS/SATA HBA for Lenovo System x - N2115 SAS/SATA HBA for Lenovo System x - Lenovo PureFlex System Storage Expansion Node - Onboard LSI 2004 SAS/SATA Controller - ServeRAID H1110 SAS/SATA Controller for Lenovo System x (81Y4492) - ServeRAID M5210e SAS/SATA Controller for Lenovo System x - ServeRAID M5210 SAS/SATA Controller - ServeRAID M5110e SAS/SATA Controller for Lenovo System x - ServeRAID M5120 SAS/SATA Controller for Lenovo System x (81Y4478) - ServeRAID M5115 SAS/SATA Controller for Lenovo System x (90Y4390) - ServeRAID M1115 SAS/SATA Controller for Lenovo System X (81Y4448) NOTE TO SERVICE - Reference RETAIN #N/A 17.05.01.02 - Moderate Impact/Low Probability of Occurrence (Suggested) ----------- 16.05.04.01 - Moderate Impact/Low Probability of Occurrence (Suggested) ----------- Fixes: - Fixed an issue where MSM was not flashing 8MB FW file on M5200 series Controllers. (SCGCQ00996185) - Fixed an issue where Dashboard view and Main View for Create Virtual Drive option are inconsistent when all drives are configure as JBOD (SCGCQ01054496) - Fixed an issue where MSM was not able set secure JBOD (SCGCQ01064281) - Fixed an issue where MSM cannot flash M1115 or M1015 controller firmware. (SCGCQ01125515) - Fixed an issue where event Block Recovery is skipped due to dirty OCR and "Please reboot the system" not seen after dirty OCR." (SCGCQ00989881) - Fixed an issue where MSM server profile shows repetitive headlines and inconsistent information for virtual drives (SCGCQ00996188) - Fixed an issue where MSM hang is observed while DIFF PD is become shielded state and then unconfigured bad. (SCGCQ00553738) - Added generic error message when update iMR image on MR controller. (SCGCQ00934328) - Corrected inconsistency in Create SSCVD option across MSM tabs. (SCGCQ01013993) - Fixed an issue where virtual drive information header printed multiple times in the profile summary page. (SCGCQ01062382) - Fixed an issue where background operations appear in profile summary without any table header. (SCGCQ01064081) - Fixed an issue where after IR controller firmware flash the popup for the update status is not displayed. (SCGCQ00916747) - Fixed an issue where MSM displayed an option to create Virtual drive even when there are no configurable disks present in RAID mode. (SCGCQ00945155) - Fixed an issue where the Creating CacheCade SSD Caching menu option is not available. (SCGCQ01117219) - Fixed an issue where connecting the expander to IR2 controller, drive ID info was not correctly displayed when the drive is inserted or deserted (SCGCQ01155781 Port of SCGCQ00898807) - Fixed an issue where title bar was missing, when trying to view the personality from SDS to Raid (SCGCQ00941885) - Fixed an issue where the create CCVD option was still seen after MAX (2TB) CCVD creation. (SCGCQ00952332) - Fixed an issue where the MSM showed wrong information about the DG in the summary page of RLM operation. (SCGCQ01039111) - Fixed an issue where MSM was not allowing to flash ctrlH on iMR controller. (SCGCQ01056002) - Fixed an issue where SWR for RHEL 6.8, driver version info was not aligned properly in MSM server profile. (SCGCQ01109158) - Fixed an issue where MSM showed inconsistent info for degraded spanned RAID Level DG's in Replace PD operation (SCGCQ01034766) - Added code to disable CreateVD menu when recon is running in case of JBOD (SCGCQ00996752) - Fixed an issue where right clicking on the VD was not opening the change properties (SCGCQ00987893 Port of Defect - SCGCQ00952349 - Fixed an issue where leaving MegaRAID Storage Manager GUI open for an extended period of time (3 to 4 days), the GUI stopped automatically refreshing and monitor stopped updating AEN's. (SCGCQ01085197 Port of Defect - SCGCQ00946664) Enhancements: - Added SLIR error codes and corresponding error messages handling to MSM. (SCGCQ00933586) - Added new operations at DG level to support MR_DCMD_LD_SET_TRASPORT_READY and MR_DCMD_LD_CLEAR_TRASPORT_READY (SCGCQ00920044) - Do not allow VD creation on Removal Ready PD (SCGCQ01027492 Port ofSCGCQ00988701) 15.11.53.00 - Moderate Impact/Low Probability of Occurrence (Suggested) ----------- Fixes: - No functional changes. 15.11.50.00 - Moderate Impact/Low Probability of Occurrence (Suggested) ----------- Fixes: - Updated OpenSSL to address FREAK vulnerability (SCGCQ00877531) - Updated Java to address FREAK vulnerability (SCGCQ00877538) - Fixed an issue where no mnemonics/shortcut keys are available for Make Unconfigured Good and Manage Link Speed menu operations (SCGCQ00711990) - Fixed an issue where MegaRAID Storage Manager does not display logs after saving logs in a text file in VMware ESXi (SCGCQ00834428) - Fixed an issue where MegaRAID Storage Manager is showing "Sequence number is out of sync" warning message for "Secure using FDE" operation (SCGCQ00836494) - Fixed an issue where MegaRAID Storage Manager did not report the correct Windows operating system name/version (SCGCQ00854632) - Fixed an issue where the option to set critical and fatal events reports in the next reboot is not present (SCGCQ00866188) - Fixed an issue where Phy Count was being shown for Enclosure Physical Disks when it should not be (SCGCQ00869437) - Fixed an issue where a user is unable to View Server Profile (SCGCQ00873250) - Fixed an issue where BBU property displays "status = Unknown" when Supercap battery is in failed state (SCGCQ00887351) - Fixed an issue where there is no option to close the host view window (SCGCQ00897401) - Fixed an issue where MegaRAID Storage manager does not allow the option to uncheck the JBOD drive which has an operating system or file system on it (SCGCQ00897404) - Fixed an issue where Controller Info may not be displayed when CacheCade is enabled and the firmware supports 240 Virtual Drives (SCGCQ00898869) - Fixed an issue where the scroll bar in the Group Progress window may disappear when starting/suspending Consistency Check on multiple Virtual Drives (SCGCQ00900408) - Fixed an issue where different information is shown in the "Create VD Summary Window" when creating in Simple Mode, and Capacity Alignment is not correct (SCGCQ00900416) - Fixed an issue where Virtual Drive numbering may be incorrect when creating more than three Virtual Drives (SCGCQ00902923) - Fixed an issue where Patrol Read may not be able to start on Partial-Size Virtual Drives (SCGCQ00918881) - Fixed an issue where Virtual Drives may not appear under the Logical tab after upgrading firmware and importing a configuration (SCGCQ00927688) - Fixed an issue where the wrong Operating System architecture may be displayed under Server Info (SCGCQ00928640) - Fixed an issue where "Create CacheCade VD" menu is displayed with max Logical Drives set, causing the operation to fail (SCGCQ00928753) - Fixed an issue where some windows may appear off-screen (SCGCQ00928758) - Fixed an issue where events are missing "Hidden" state of Virtual Drives (SCGCQ00933592) - Fixed an issue where Physical Drive information in Event Information is blank, but is correctly displayed in Backplane Properties (SCGCQ00933603) - Fixed an issue where destination drive is not listed under Logical View during a Copyback (SCGCQ00934374) - Fixed an issue where the Write Policy may not be correct after creating a Virtual Drive (SCGCQ00934377) - Fixed an issue where "Next Learn Cycle Time & Learn Period" may not be displayed when battery supports Transparent Learn (SCGCQ00934380) - Fixed an issue where "Online Firmware Update in progress" is showing after controller reset using storcli completes (SCGCQ00934505) - Fixed an issue where logs saved as Text file are missing Enclosure IDs in the events (SCGCQ00934595) - Fixed an issue where Operating System and Health fields are showing Unknown from the remote server Discovery page (SCGCQ00934721) - Fixed an issue where an application restart pop-up may occur while downgrading firmware, citing 240 Virtual Drive support (SCGCQ00939249) Enhancements: - Enhanced the port enumeration naming scheme (SCGCQ00854619) - Added ability to select a range of events to parse when generating Alert Notifications (SCGCQ00854627) - Added ability to report controller flash device health status (SCGCQ00887610) - Changed Consistency Check / Patrol Read overlap message from Warning to Informational (SCGCQ00887611) - Added ability to handle MFI and SL error codes with corresponding error messages (SCGCQ00942678) 15.05.01.52 - Moderate Impact/Low Probability of Occurrence (Suggested) ----------- Fixes: - Fixed an issue where MSM may not report HDD temperature information for drives in slot 0 connected to SWRAID - (SCGCQ00895878, Port of SCGCQ00867490) - Fixed an issue where Japanese Language packs may cause email alerts to be garbled - (SCGCQ00890256) - Fixed an issue where MSM may have a garbled character instead of 'TM' by using UNICODE \u2122 instead of ASCII 0x99 - (SCGCQ00880993) - Fixed an issue where event ID 150 descriptions were not consistent between the alert strings and the event properties - (SCGCQ00881952) Enhancements: - Provide more descriptive port enumeration based on width of the port (SCGCQ00895884, Port of SCGCQ00854619) 15.05.01.51 - Moderate Impact/Low Probability of Occurrence (Suggested) ----------- Fixes: - Corrected the output for the key MSG_ASSOCIATED_SSCDDELETE_TEXT1 value with corresponding unicode for @TM Symbol in resource files (SCGCQ00880993) - Corrected the inconsistency in description for Event ID 150 between alert Strings.xml and MR_Events.properties 15.03.01.00 - Moderate Impact/Low Probability of Occurrence (Suggested) ----------- Fixes: - OpenSSL security fixes 14.11.01.05 - High Impact/High Probability of Occurrence ----------- Fixes: - Incorporated MSM MegaRAID 6.6 stream - Fixed an issue where "Remove JBOD" option may not warn client even if the drive has a filesystem (SCGCQ00704645) - Updated the StorCLI within MSM to the latest (SCGCQ00707316) - Fixed an issue where MSM may still provide option to create a VD even after max VDs have been created (SCGCQ00707466) - Fixed an issue where Enclosure details may not be shown in ViewServerProfile (SCGCQ00709507) - Fixed an issue where "Select All" and "Start" buttons are enabled in Consistency Check window curing CC on only one VD (SCGCQ00740485) - Fixed some null pointer dereferences in MSM EventXMLFormation (SCGCQ00757780) - Fixed an issue where MSM may allow a CacheCade VD to be recreated with Always Write Back option (SCGCQ00759986) - Fixed an issue where the message for Dedicated Hot Spare is missing the VD name (SCGCQ00770874) - Fixed an issue where the Create Virtual Drive icon is still active when it shouldn't be (SCGCQ00772351) - Fixed an issue where MSM popup showing Patrol Read progress even after setting Max Concurrent PDs for Patrol Read to 0 (SCGCQ00774583) - Fixed an issue where "Initialization Aborted" message does not show up in MSM (SCGCQ00706130) - Fixed an issue where a Bootable JBOD with the OS on it shows as eligible for conversion to Unconfigured Good (SCGCQ00742001) - Fixed an issue where Null Pointer Exceptions were being thrown in the AdapterMenu (SCGCQ00757770) - Removed unused CIMPlugin dependencies in CacheCacde and modify the folder structures for respective OSes (SCGCQ00757819) - Fixed an issue where a user may be able to login twice in a point of time as Administrator Full Access (SCGCQ00760231) - Fixed an issue where discovery may fail after MSM installation with 1024bit keys on RHEL (SCGCQ00787334) - Fixed an issue where the Graphical view for Enclosures may not be correct (SCGCQ00717047) - Fixed an issue where MSM cannot create any RAID level if the drives are selected one by one (SCGCQ00734568) - Fixed an issue where the shortcut key for Manage Link Speed menu option is not present (SCGCQ00709792) - Fixed an issue where MSM shows an incomplete window for Advanced Software Options when using shortcut key as opposed to regular menu option (SCGCQ00713213) - Fixed an issue where the Select All button is enabled in the Initialize window when only one R6 VD is available with partially degraded mode (SCGCQ00759357) - Fixed an issue where MSM may throw "Requested command cannot be completed because resources are already in use" or "Invalid array specified "when creating arrays in specific circumstances (SCGCQ00762640) - Fixed an issue where MSM may report CacheCade VD has been deleted even though it is still being deleted by firmware (SCGCQ00777823) - Fixed some null reference issues (SCGCQ00766100) - Fixed an issue where volume creation fails in MSM if the controller has firmware that supports 240 VDs (SCGCQ00664507) - Fixed an issue where Consistency check cannot be scheduled in 64-bit Linux managing an ESXi host (SCGCQ00757859) - Fixed an issue where "Select All" and "Start" buttons are enabled in Initialization window during Init on only one VD (SCGCQ00727600) - Fixed an issue where one is unable to create a second VD in MSM through Dashboard "Create Virtual Drive" link (SCGCQ00766971) - Fixed an issue where cannot uninstall MSM via uninstaller.sh script in RHEL6.5 (SCGCQ00691368) - Fixed an issue where MSM fails to save Host Configuration Settings (SCGCQ00691421) - Fixed an issue where alert strings for events 502, 512, 513 and 514 may be wrong (SCGCQ00698294) - Fixed an issue where there may be a fatal error when logging in via Server button on top and trying to refresh using the option button on top (SCGCQ00727445) - Fixed an issue where updating MSM may fail in Windows (SCGCQ00727990) - Fixed an issue where MSM may display an invalid field (Parity Size) for R00 (SCGCQ00687943) - Fixed an issue where a SuperCap reported as Bad may still show as Optimal (SCGCQ00785419) - Fixed an issue where "Prepare for Removal" on PD may not work on PD with pending operations (SCGCQ00784866) - Fixed an issue where R6 option may be displayed during migration of a 31-drive R0 (SCGCQ00703809) - Fixed an issue where event log shows "null" instead of correct VD where Snapshot schedule properties have changed (SCGCQ00795792) - Fixed an issue where R1 option may be displayed during migration of a 7-drive R0 (SCGCQ00694232) - Fixed an issue where MSM may not login to remote host in the favorite list (SCGCQ00692364) - Fixed an issue where entering security key in MSM to unlock PD fails to import afterwards (SCGCQ00785420) - Fixed an issue where MSM may scroll additional Sense Info constantly after refreshing screen for SATA (SCGCQ00789079) - Fixed an issue where Consistency Check is grayed out after disabling through MSM and can't be reenabled through MSM (SCGCQ00795183) - Fixed an issue where one is unable to stop the MSMFramework service (SCGCQ00756996) - Fixed an issue where Create Virtual Drive option is lost in MSM (SCGCQ00822350) - Fixed an issue where there may be many blank messages in the MSM logs on controllers with multiple VDs (SCGCQ00827667) - Fixed an issue where timestamps are incorrect in TTY logs saved through MSM (SCGCQ00829187) - Fixed an issue where after creating a spanned VD, MSM creates duplicate drive groups (SCGCQ00830891) - Fixed an issue where "TIME = Not Available" message appears in text file of events saved through MSM (SCGCQ00832354) - Fixed an issue where during install MSM may show erroneous "major upgrade" warnings and errors and asks for restart of the system (SCGCQ00817865) - Fixed an issue where MSM may not import SED / FDE Foreign Config using previous security key (SCGCQ00823013) - Fixed an issue where Patrol Read and Consistency Check schedule overlap errors were listed as Warnings instead of Informational (SCGCQ00821374) - Fixed an issue where the MSM log may be flushed after host reboot (SCGCQ00800288) Features/enhancements - Added the ability to display PCI Domain information, instead of just PCI Bus and Device (SCGCQ00712488) - Added latest Pegasus library v2.13 (SCGCQ00650093) - Recompiled Pegasus libraries for Windows with the latest OpenSSL (SCGCQ00729736) - Added support for 2048bit RSA keys (SCGCQ00696866) - Added support for reporting drive temperatures for all SAS/SATA HDDs/SSDs (SCGCQ00650088) - Added PFK support for SSHA (SCGCQ00707653) - Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00821360) 14.05.02.03 - Moderate Impact/Low Probability of Occurrence (Suggested) ----------- Fixes: - MSM reports full version nubmer to Lenovo comparison tools. - Fixed an issue where MSM alert for event ID 81 and ID 114 do not give notification. - Fixed an issue where MSM could not uninstall via uninstaller.sh script in RHEL 6.5. - Fixed an issue where MSM is not showing the "Selected Firmware Version" during online firmware update. - Fixed an issue where server status doesn't changes accordingly with IR2 controller in MSM login page. - Fixed an issue where MSM login screen missing host and OS name. - Fixed an issue where menu items load configuration and scan configuration are highlighted when the controller is in safe mode. - Fixed an issue where inconsistent write policy during EVS creation in MSM. - Implement SuperCap deep dive action items in the firmware and applications - Fixed an issue where MSM simple create virtual disk dialog box disappears for ServeRAID H1110 - Fixed an issue where virtual drive erase option is not found. - Fixed an issue where MSM is throwing error code 0 x 32. - Fixed an issue where starting patrol read throwing error '0x58' when virtual disk erase is running. - Fixed an issue where MSM not reporting events for changes that occurred to IR volumes during power off. - Fixed an issue where MSM displays unsupported SATA drives for replace operation for regular 512n drives - Single Node. - Fixed an issue where MSM displays invalid field name for disabling data protection. - Fixed an issue where 4K virtual disk size is wrong during import of 64 virtual disk s - Single Node. - Fixed an issue where MSM need to return error when destroy key on peer node with existing secure virtual disk. - Fixed an issue where the user cannot uninstall MSM without xterm installed under Linux. - Fixed an issue where MSM login screen missing the domain ID column at the most right. - Resolved OpenSSL vulnerabilities. 13.11.01.07 - Initial release -----------
Twoja opinia pomoże poprawić ogólny komfort użytkowania
ID Aliasu: LSI-LNVGY_UTL_MSM_17.05.01.02_WINDOWS_X86-64
Fix ID: lsi-lnvgy_utl_msm_17.05.01.02_windows_x86-64
data publikacji: 15 Nov 2017
Data pierwszej publikacji: 15 Nov 2017
Identyfikatof dokumentu : DS501345