Intel Networking Adapter/Device Linux Firmware
Available Drivers
Intel Networking Adapter/Device Linux Firmware
Red Hat Enterprise Linux 8 (64-bit)
SUSE Linux Enterprise Server 12 (64-bit)
SUSE Enterprise Linux Server 15 (64-bit)
Platform
Red Hat Enterprise Linux 9 (64-bit)
Payload Package
intc-lnvgy_fw_nic_net.e800.da2.pcie.sd-4.22-1.3357.0-4_linux_x86-64.bin
Red Hat Enterprise Linux 8 (64-bit)
SUSE Linux Enterprise Server 12 (64-bit)
SUSE Enterprise Linux Server 15 (64-bit)
Platform
Red Hat Enterprise Linux 9 (64-bit)
Change History
intc-lnvgy_fw_nic_net.e800.da2.pcie.sd-4.22-1.3357.0-4_linux_x86-64.chg
Red Hat Enterprise Linux 8 (64-bit)
SUSE Linux Enterprise Server 12 (64-bit)
SUSE Enterprise Linux Server 15 (64-bit)
Platform
Red Hat Enterprise Linux 9 (64-bit)
Release Notes
intc-lnvgy_fw_nic_net.e800.da2.pcie.sd-4.22-1.3357.0-4_linux_x86-64.txt
Red Hat Enterprise Linux 8 (64-bit)
SUSE Linux Enterprise Server 12 (64-bit)
SUSE Enterprise Linux Server 15 (64-bit)
Platform
Red Hat Enterprise Linux 9 (64-bit)
XML file
intc-lnvgy_fw_nic_net.e800.da2.pcie.sd-4.22-1.3357.0-4_linux_x86-64.xml
Red Hat Enterprise Linux 8 (64-bit)
SUSE Linux Enterprise Server 12 (64-bit)
SUSE Enterprise Linux Server 15 (64-bit)
Platform
Red Hat Enterprise Linux 9 (64-bit)
Description
Device Support: X810
OS Support:
What's More
Change History
=========================================================================== Intel v28.0 Network FW Update Release for Linux Release date = 02/16/2023 Package Version: net.e800.da2.pcie.sd-4.22-1.3357.0-4 =========================================================================== CONTENTS ________ 1.0 Change history 2.0 Web information and support phone Number 3.0 Notices and trademarks 4.0 Disclaimer 1.0 Change history ___________________ This FW update package supports Lenovo E810 Clifton Channel dual port SFP product ONLY. This release includes the following updates: ============================================ Versions: 1) The following E810 images are at NVM 4.22 level. ----------------------------------------------------------------------------------- Device Boot ROM (Option ROM) Firmware (Etrack ID) ----------------------------------------------------------------------------------- ThinkSystem E810-DA2 PCIe 1.3357.0 80019449 2) NVMUPDATE tool updated to 1.39.32.6 to support new config version. New features: - Support RHEL8.7/9.1, ESXi 8.0 - OROM update support in Recovery mode Description: With this implementation, the NVM host update flow in recovery mode should be the same as in the operational mode. - Defines the IID (Instance IDs) field in the NC-SI packetâs header, which is used to match responses to requests and to differentiate between new and retried commands. Description: According to the spec, If the IID of the current command is the same as the previous commandâs IID, the command is a "Retried Command" and the FW shall return the response of previous command (should be done without re-executing the command). When the IID is different than from the previous command, the command is executed. The NC-SI spec is unclear on if the incoming commands IID is compared to the IID of the previous command received on the same channel, package or device. This feature defines a transfer to maintaining a single buffer for the last NC-SI command received on the device per transmitting interface. - Add FC-FEC(CL74) support with optical transceiver 25G-SR - NVMUpdate - only access devices from config file Description: The affected component shall only access devices (read/write flash or registers) listed in config file that match the following criteria: * if device in config file contains: DEVICE and VENDOR all devices with specified device ID and vendor ID will be accessed; * if device in config file contains: DEVICE, VENDOR, SUBDEVICE, SUBVENDOR all devices with specified 4partID will be accessed, * if device in config file contains: DEVICE, VENDOR, SUBDEVICE, SUBVENDOR, REVISION all devices with specified 4partID and specific revision will be accessed. Device not listed in config file (do not match the criteria above) shall be marked as "Update not available' in interactive mode. - NVMUpdate - OROM update in recovery Description: If the device is in recovery mode and has the capability of supporting for OROM update in recovery mode. it can be updated OROM either from NVM image or from separate file (FLB). - RoCEv2 LAG - FEC auto-detect for CVL LR/SR mode Description: Only valid FEC modes will be attempted based on the media and PHY type. - Enable hardware arbitration - IPS: 00675913 - FEC Configuration through UEFI HII for 25G CVL adapters Bug fixes: - IPS: 00796141 - E810 fails to link with 10/25Gb SFP28 connect to adapter and 10Gb SFP+ connected Description: Connect Lenovo 10/25Gb SFP28 to E810, Lenovo 10Gb SFP+ to switch (CISCO 9K) Link fails to come up. Fix: Change the preserved "inkDefaultOverridess"ields in the NVM image so that the settings in the NVM images make the firmware to try all the FEC modes during the link training. - IPS: 00736066 - [PA_IO Agile-Sprint202209_BDC_Storage_SR655] E810-DA2 OCP ShareNIC cannot obtain DHCP IP under SR655 Description: BMC failed getting an IP address on the sharenic port of E810-xxvDA2 OCP via DHCP Fix: Use proper packageID SDP settings for SDP0 and SDP1 - IPS: 00735574 - [PA_QUR 22C_BDC_SDV_FW_AMD1P_UEFI][RMK-5883]E810-DA4 OCP Ethernet Adapter cannot obtain DHCP IP Destination: E810-DA4 OCP Ethernet Adapter cannot obtain DHCP IP. Fix: In implementation, use different variables to identify VSI in different context. - Both ports are loosing link randomly after dcb-map change Destination: The E810 adapter might experience an adapter-wide reset (all ports) when the DCBx willing configuration change (in firmware managed mode) propagated from the switch removes a TC that was RDMA enabled. This typically occurs when removing a TC associated with UP0 because itâs the default UP that RDMA based itâs configuration on. The reset results in a temporary loss in connectivity as the adapter re-initializes. Fix: FW changes along with changes in SW to allow for RDMA to disable QueueSets before suspending the removed TCs from the scheduler tree. Release net.e800.da2.pcie.sd-4.01-1.3282.0-10 includes the following updates: ============================================================================= New features: - Support Windows 11 - Support RHEL8.6/9.0, SLES 15SP4 - Support scalable IOV feature (S-IOV) on the 4th Gen Intel® Xeon® Scalable Processor with the following drivers and OS: o ice 1.9.11 or later o iavf 4.5.3 or later o RHEL 7.9 and 8.5 o SLES 12.5 and 15.3 Note: Please refer to document for more details. Bug fixes: - IPS: 00665409 - [IO_Tatlow_BBFV[UEFI] Intel E810-DA2 PCIE Ethernet Adapter changes do not take effect in network device. Description: During POST, in UEFI setup, set "Active Physical Functions" to "PF0" and save. However, it will still be set to "All" after reboot. Fix: Added a check to ensure only PF0 is used during HII value set. - IPS: 00673260 - E810 OCP adapter fails to link on D-Link switch but E810 PCIe adapter is able to establish link Description: With the same setup, E810 PCIe adapter links up, but E810 OCP adapter can't link up. Fix: Added new section in NVM to match the requirement and bring up link correctly. - IPS: 00688647 - BSOD seen on E810 ICEA driver when using SRIOV/RDMA Description: A customer has SR645 servers in a cluster running Windows 2019 Hyper-V. with SRIOV and RDMA. Randomly the server crashes with a BSOD. Fix: Updated driver to use correct lock and set correct status of queues in passive level thread - IPS: 00711180 - E810-DA2 has no Share NIC feature Description: No Shared option and only Dedicated in the field of Network Interface Port. Fix: Uses correct packageID definition in NVM image. 2.0 Web Sites and Support Phone Number ______________________________________ o You can download new and updated files for Lenovo products from the Lenovo Web site: http://datacentersupport.lenovo.com/ o With the original purchase of an Lenovo hardware product, you have access to extensive support coverage. During the Lenovo hardware product warranty period, you may call the Lenovo HelpCenter for hardware product assistance covered under the terms of the Lenovo hardware warranty. 3.0 Trademarks and Notices __________________________ Lenovo is a registered trademark of Lenovo Corporation in the United States and other countries. Intel is a registered trademark of Intel Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds in the United States and other countries. Other company, product, and service names may be trademarks or service marks of others. 4.0 Disclaimer ______________ THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. Lenovo DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, Lenovo GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. Note to U.S. Government Users -- Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with Lenovo Corporation.
Your feedback helps to improve the overall experience
Alias Id: INTC-LNVGY_FW_NIC_NET.E800.DA2.PCIE.SD-4.22-1.3357.0-4_LINUX_X86-64
Fix ID: intc-lnvgy_fw_nic_net.e800.da2.pcie.sd-4.22-1.3357.0-4_linux_x86-64
Release Date: 25 May 2023
Original Publish Date: 25 May 2023
Document ID: DS563281