Description
Device Support: 810-4p NVMe Switch
OS Support: Any OS
What's More
Change History
Firmware Update for ThinkSystem 810-4P NVMe Switch Card Supported Adapters: ThinkSystem 810-4P NVMe Switch Card NOTE TO SERVICE - Reference RETAIN #N/A Version 00.05.64.00 ------------------- -Updated virtual bridge link width capablity as per respective physical ports capability and MPI EP, enabler EP linkwidth to x4.(DCSG00925580) Version 00.05.61.00 ------------------- -Removed WA restricting switch P2P bridge MPS to 128B.(DCSG00167433) -PCI3 Swith: Include ECRC field while calculating TLP length if the TD bit is set.(DCSG00167433) Version 00.05.55.00 ------------------- (New) Removed WA restricting switch P2P bridge MPS to 128B Version 00.05.52.00 ------------------- (Fix) Fixed issue NVME drives not detected in BIOS Version 00.05.51.00 ------------------- (Fix) Fixed couple of issues related to inband FW update. (Fix) Fixed defect wrong PLDM sensor count. Version 00.05.11.00 ------------------- New: - Add In-Band FW udpate function Fix: - Configuration changes of preventing it to be set to âcompliance pollingâ state - Bug 163203 : The inventory info of NVMe SSDs attached in the switch show incorrect on XCC WebUI during AC power cycle stress Version 00.05.09.00 ------------------- Fix: - Bug 148880 - [PA][Rich Server][IEC-Stress] Randomly lost NVME hard drives in OS during AC cycle test. - Bug 140977 - [PA_SR250_SDV_COM_Software][UXSP]lnvgy_fw_nvmeswitch_00.05.05.00_anyos_noarch update fail through OOB - SCGCQ01903751/145044 Lenovo Server: LED Management Not Working if One or More Miramar / Pembroke Ports is Not Connected - SCGCQ01891748/ 138162 Lenovo Mehlow SR250 system NVMe detection issue with PEX9733 Version 00.05.05.00 - Initial Release -------------------
Your feedback helps to improve the overall experience
Alias Id: LNVGY_FW_STOREHBA_MPT3.NV.810.4P-00.05.64.00-0_ANYOS_NOARCH
Fix ID: lnvgy_fw_storehba_mpt3.nv.810.4p-00.05.64.00-0_anyos_noarch
Release Date: 31 Aug 2022
Original Publish Date: 31 Aug 2022