Lenovo StorCLI Storage Host-Bus-Adapter (HBA) Windows Utility

2.472 MB
mpt3.storcli-007.2205.0000.0000-0

Windows Server 2019

Windows Server 2022

28 Mar 2023
Suggested

change history

lnvgy_utl_storehba_mpt3.storcli-007.2205.0000.0000-0_windows_x86-64.chg

264.35 KB
mpt3.storcli-007.2205.0000.0000-0

Windows Server 2019

Windows Server 2022

28 Mar 2023
Suggested

readme

lnvgy_utl_storehba_mpt3.storcli-007.2205.0000.0000-0_windows_x86-64.txt

13.9 KB
mpt3.storcli-007.2205.0000.0000-0

Windows Server 2019

Windows Server 2022

28 Mar 2023
Suggested

StorCLI command line tool for windows

lnvgy_utl_storehba_mpt3.storcli-007.2205.0000.0000-0_windows_x86-64.zip

2.2 MB
mpt3.storcli-007.2205.0000.0000-0

Windows Server 2019

Windows Server 2022

28 Mar 2023
Suggested

Description

Device Support: HBA-430-x, HBA-440-x
OS Support: Windows 2019, Windows 2022

What's More

Change History

StorCLI (Command Line) Utility for Storage Management

Adapters Supported:
	ThinkSystem 430-8i SAS/SATA 12Gb HBA for 7Y37A01088
	ThinkSystem 430-16i SAS/SATA 12Gb HBA for 7Y37A01089
	ThinkSystem 430-8e SAS/SATA 12Gb HBA  for 7Y37A01090
	ThinkSystem 430-16e SAS/SATA 12Gb HBA for 7Y37A01091
	ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA  (NA-StarkSASHBA)
	ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA for 4Y37A09724
	ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBA for 4Y37A09725

NOTE TO SERVICE - Reference RETAIN #N/A
007.2205.0000.0000 - Moderate Impact/Low Probability of Occurrence
--------------------
MR 7.20

Defects:
-Storcli : Copyright shows as year 2021 instead of 2022 & also build release year 2021 instead of 2022 & also build release year shows as 2021 instead of 2022.(DCSG01124638)
-Error seen while flashing psoc.rom in efi CLI.(DCSG01131584)
-storcli 7.2001 does not return values for a bad drive.(DCSG01052072)
-Spellling of mismatch is displayed as "Missmatch" in "Encryption type missmatch" error message..(DCSG01091937)
-Device Type for Backplane in Alilog shown as Enclosure.(DCSG01109911)
-Storcli shows Protection Information (PI) capable drive i.e. "PI eligible" as No, however LSA shows it properly.(DCSG01145223)
-CLI not iterating through MR_SAS_CONNECTORS for H750 controllers.(DCSG01077564)
-Instance validation fails for "/c0 show all" and "controller-detailed-properties-schema.json".(DCSG01035798)
-OS drive name shown as N/A for multiple VDs.(DCSG01101813)
-Storclif reports BBU instead of cachevault for failed retention tests.(DCSG01092227)
-Storclif 7.2005 can't start retention test, says No CacheVault Found!.(DCSG01130532)
-Enclosure logical ID field is not displayed for BP connected to connected to Boca 540-16i controller.(DCSG01024654 (Port Of Defect DCSG01024693))
-Set Patrolread command hangs while setting "excludevd".(DCSG01101780 (Port Of Defect DCSG01102890))
-Strocli.efi utility got hung on issuing "storcli /c0 show" command.(DCSG01049757 (Port Of Defect DCSG01050540))
-"storcli /call show" shows jumbled drives in a Multi IT controller environment.(DCSG01040245 (Port Of Defect DCSG01040583))
-PD size displayed in Gib for some of the 4K drives is incorrect..(DCSG00389591 (Port Of Defect DCSG00994728))
-PD Firmware Release Number = N/A is displayed for drive which has valid Firmware Release Number.(DCSG01083763 (Port Of Defect DCSG01083800))
-Storcli shows success without proper description for "VD delete BBMT" command when no VD present..(DCSG01002466 (Port Of Defect DCSG01024694))
-Update splitpackage script for shenandoah.(DCSG00651204 (Port Of Defect DCSG00994744))
-While trying to import foreign config, Storcli is not showing any drive if user has "Dedicated Hotspare" & also DHS is not displaying along with VD as well.(DCSG01034883 (Port Of Defect DCSG01036901))
-While trying to import foreign config, Storcli is not showing drive as "Hotspare" if the user has only hot spares.(DCSG01028926 (Port Of Defect DCSG01029835))

EnhancementRequests:
-Update ControllerInfo Structure with PartNumber - API Changes.(DCSG01064529)
-Request for Win2022 Supportnfor their 16G Enablement launch, March 2022 RTS.(DCSG00977684)
-MegaRAID key management feature: volatile key escrow.(DCSG00992844)
-secureSignBin: implement feature to download the public key during signing or with explicit arg.(DCSG01035866)
-DCSG01082488
-API change to support PD sanitize operations enhancements.(DCSG01070995)
-Aero 9560/9580 - Add PSOC6 as Vision Controller.(DCSG01056506)
-Add control command MFI_OOB_MCTP_CONTROL_EXCEPTION_NO_CMD (0x99) in API.(DCSG01065378)
-Change the attribute name "Secured" to "Locked" in PD Properties output.(DCSG01040562 (Port Of EnhancementRequest DCSG01040785))
-Handling of VD target-ID's individually even when target-ID is assigned beyond maxLDs.(DCSG01091990 (Port Of EnhancementRequest DCSG01092477))
-Windows Client Win11 OS Support.(DCSG01043616 (Port Of EnhancementRequest DCSG01068906))

007.1907.0000.0000 - Moderate Impact/Low Probability of Occurrence
--------------------
MR 7.19

Defects:
-While trying to import foreign config, Storcli is not showing any drive if user has "Dedicated Hotspare" & also DHS is not displaying along with VD as well.(DCSG01034883)


007.1707.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------- 
MR 7.17

Defects:
-StorCLI listing failed NVMe drives in non-sorted order.(DCSG00320844
-Instance Validation Failed for "/call/fall show all.json" and foreign-configuration-detailed-schema.json.(DCSG00408509
-MR7.16_storcli: VD creation with the remaining drives fails.(DCSG00303606
-Enclosure position is showing as - for drive detailed properties on an IT controller.(DCSG00286693
-Package Version is not displayed properly after flashing firmware..(DCSG00961822
-PH18 BETA - StorCLI - Update YEAR in the CLI banner.(DCSG00707142
-Storcli launch fails with permission denied message.(DCSG00972016
-Setting CC date and time exceeding the limit, needs to be handled.(DCSG00520110
-"rval - 0" is displayed for "show phyerrorcounters" command..(DCSG00337710
-Storcli lists "/ex show all" for "/cx show all" command..(DCSG00417504
-DiskGroup show all list Hostpare in Unconfigured drive list.(DCSG00359247
-Storcli: learnStartTime displayed incorrectly in command details.(DCSG00320649
-Storcli /cx set debug reset all help description needs an update.(DCSG00521571
-storcli /cx set flushwriteverify help needs an update.(DCSG00507067
-PH17 PA - StorCLI ARM - show file command displays incorrect output for BIOS image.(DCSG00315152
-PH18 PA - StorCLI - appropriate message needed for erase all excludemfg command.(DCSG00395234
-Storcli shows "success" with incorrect message INSTEAD of syntax error for "/c0/d1 set" command..(DCSG00543505
-storcli show alilog shows "SATA-3G" as device interface for 9361-16i.(DCSG00555672
-Handling PBLP component whild displaying Image component versions.(DCSG00301878
-MR_7.17: After Driver unload/load via DDV tools- Ctrl acces via Storcli exit with Segmentation Fault.(DCSG00426317
-coverity: fixing non-array delete and dereferencing before NULL checks.(DCSG00368376
-Handling the read-only file system from storcli.(DCSG00542683
-Updating new SPDM MPI errors.(DCSG00435039
-"Failed Drive not found" reported from enclosure level show repair command.(DCSG00423496
-Controller Lane show command is not working with individual Lanes.(DCSG00386181
-Storcli show command is not displaying remaining drives when PD info fails for one drive.(DCSG00469639
-VD creation fails from storcli even though free capacity is present in DG.(DCSG00757768
-Aero 7.15 CLI shows a extra space in the /c0 set cc h command.(DCSG00298943
-Instance Validation Failed for "/call show" and controller-properties-schema.json.(DCSG00408497
-show alilog command displays JBOD as volumes.(DCSG00556934
-Instance Validation Failed for "/call/fall import preview.json" and foreign-configuration-detailed-schema.json.(DCSG00408512
-Max commands for averaging needs to be removed from DPMstat RA output.(DCSG00286349 (Port Of Defect DCSG00306711)
-Failure observed while running set sbr command.(DCSG00779151 (Port Of Defect DCSG00932922)
-Storcli "/call/eall/sall download status" error message needs correction..(DCSG00735452 (Port Of Defect DCSG00757676)
-Unified StorCLI MR7.15 - Fixing coverity issues - Part 1.(DCSG00290662 (Port Of Defect DCSG00368612)
-Atlas 4.2: StorCLI lists wrong error message "Failed in standard Inquiry", when user tries to upgrade/downgrade all connected NVMe Drives FW at a time.(DCSG00309398 (Port Of Defect DCSG00313432)
-The foreign config of DHS/GHS details is not listing under foreign config import preview.(DCSG00919659 (Port Of Defect DCSG00935761)
-Invalid Array Size in ZB is displayed for Degraded R1 span Foreign VD in storcli foreign import preview.(DCSG00916209 (Port Of Defect DCSG00935751)
-Logical ID of Cobra expander not displayed properly in Storcli and LSA.(DCSG00342456 (Port Of Defect DCSG00391477)
-CLI crashes when issuing the phyerrorcounters command on a 14G Expander backplane.(DCSG00323054 (Port Of Defect DCSG00323721)
-Show command status not proper when issued with wrong EID.(DCSG00906544 (Port Of Defect DCSG00935762)
-Storcli shows no output for valid parameter for "/c0/p0,1,22 show" command..(DCSG00840944 (Port Of Defect DCSG00932927)
-From the CLI failed to convert UBAD state drive to UGOOD.(DCSG00391494 (Port Of Defect DCSG00391509)
-Non Foreign drives GHS are listing under Foreign import preview.(DCSG00931210 (Port Of Defect DCSG00935765)
-Storcli "show file" command does not report correct FW version.(DCSG00299788 (Port Of Defect DCSG00302030)
-Storcli show incorrect property name for "/c0/d0,3 set hidden=off" command..(DCSG00733214 (Port Of Defect DCSG00758467)
-Coverity fixing bad allocator and resource leaks.(DCSG00307346 (Port Of Defect DCSG00307355)
-Vses Device Type is displayed as Enclosure for IT card.(DCSG00920244 (Port Of Defect DCSG00935772)
-StorCLIF fail to flash firmware image of BTBL (BOOT_BLOCK) on Invader MR.(DCSG00330381 (Port Of Defect DCSG00353198)
-Storcli throws junk value is shown on set consistency check.(DCSG00906989 (Port Of Defect DCSG00935693)
-MR 7.15 StorCLI : Addressing Coverity defects.(DCSG00286677 (Port Of Defect DCSG00311222)
-CLI Version info is seen in continuation of Sense data when executed show events.(DCSG00935802 (Port Of Defect DCSG00935973)
-VDs imported from Jbod mode to RAID do not have OS name available in Linux OS.(DCSG00968023 (Port Of Defect DCSG00975216)
-CLI failing to stop a BGI or CC when paused..(DCSG00735544 (Port Of Defect DCSG00757870)
-Enclosure phyerrorcounters fails in VMware platform.(DCSG00706496 (Port Of Defect DCSG00706497)
-Storcli shows success for "set patrolread excludevd" command failure in the presence of VD..(DCSG00906735 (Port Of Defect DCSG00935770)
-For empty SPDM slots 0 & 1 show security slot info command shows as Invalid data on IT controller..(DCSG00348125 (Port Of Defect DCSG00353186)
-Segmentation fault noted with drive firmware update.(DCSG00758645 (Port Of Defect DCSG00932904)
-VD creation output shows VD size as 0KB when it reaches maximum supported virtual disks(64VDs) in a DG..(DCSG00349415 (Port Of Defect DCSG00353914)
-SAS drive Inquiry data is not shown in drive show all output.(DCSG00778367 (Port Of Defect DCSG00932917)
-Fixing Coverity defects of MR 7.15.(DCSG00299981 (Port Of Defect DCSG00309219)
-Post reboot incorrect lane speed is displayed in Storcli when user sets it to 16GT/s.(DCSG00383336 (Port Of Defect DCSG00395901)
-On storcli /c0/v1,2,3,4 del if anyone of the vd in the series is not present then all the vd's are not deleted.(DCSG00264571 (Port Of Defect DCSG00266888)
-Coverity defects - remove resource leaks, invalid types in function arguments.(DCSG00269017 (Port Of Defect DCSG00277861)
-Storcli will not show LargeIOsupport is enabled/disabled on the controller.(DCSG00353195 (Port Of Defect DCSG00353882)
-Storcli shows target id of the drive as boot drive instead of showing drive slot number for JBOD drives..(DCSG00344079 (Port Of Defect DCSG00353203)
-MR7.15_storcli: With the latest storcli, VD creation with the remaining drives fails.(DCSG00278049 (Port Of Defect DCSG00282590)
-Removed leading spaces for SATA drives.(DCSG00904104 (Port Of Defect DCSG00935692)
-Drives connected to IT controller reports Shield Counter.(DCSG00244631 (Port Of Defect DCSG00266881)
-Size of Degraded R10 Foreign VD is displayed as 0 KB in storcli.(DCSG00916207 (Port Of Defect DCSG00935746)

EnhancementRequest:
-Adding new License file and updating the build script to include the new file.(DCSG00324401
-Add CLI command to control Parity Read Cahce Bypass for SSD VDs.(DCSG00342282
-MR7.16 : Support WJ Pinning for both WB and WT Parity RAID VDs.(DCSG00214472
-Provide option in storcli to disable / enable the Preboot trace Buffer feature in MR FW..(DCSG00310366
-Enable cache retention testing on Shenandoah controllers for factory testing.(DCSG00340899
-Updating storcli code and makefiles to support VBAS builds on GCP.(DCSG00412063
-Additional NameSpace behavior changes.(DCSG00310386
-Updating storcli BST scripts to support new VBAS Auto BST procedure.(DCSG00282976
-StorCLI: Automate the test cases specific to MR7.17 Product Requirements.(DCSG00433350
-Add support for reporting SPDM Measurement Specification and Hash Algorithm.(DCSG00301782
-Updating command legends as per the command output.(DCSG00083851
-IT Drive Model Number , Revision for SATA drives displayed in full.(DCSG00371061
-MR7.16: StorCLI does not show the SAS Address of the enclosure.(DCSG00255109
-Unified StorCLI 7.17 - x64 UEFI VBAS / GCP support.(DCSG00559813
-Updating Error Strings for NVME init error codes in Apps.(DCSG00434066
-MR7.16 StorCLI: Ruby SED Support.(DCSG00264744
-CLI to handle ERROR_BUSY from Windows storport.(DCSG00348813 (Port Of EnhancementRequest DCSG00353214)
-Displaying "OS name" for VDs imported from EHBA mode to RAID.(DCSG00775114 (Port Of EnhancementRequest DCSG00932911)
-Display Enclosure serial No in Storcli.(DCSG00500922 (Port Of EnhancementRequest DCSG00932906)
-Request to add checks (DevId, SubDevice Id) check prior to flashing.(DCSG00500924 (Port Of EnhancementRequest DCSG00521828)
-SEKM Support in CLI.(DCSG00433143 (Port Of EnhancementRequest DCSG00935780)
-CLI: Package Stamping Verification During Firmware Update.(DCSG00239672 (Port Of EnhancementRequest DCSG00282815)
-StorCLI has the ability to switch the OOB mode.(DCSG00547179 (Port Of EnhancementRequest DCSG00935783)
-SMART Polling Improvement - PERC 10.(DCSG00249963 (Port Of EnhancementRequest DCSG00282814)
-PERCcli turn off logging by default.(DCSG00255367 (Port Of EnhancementRequest DCSG00282813)
-Remove the MFG date, Revision date and Rev from IT StorCLI output.(DCSG00415059 (Port Of EnhancementRequest DCSG00418372)
-Display port information for NVMe Init failed drives.(DCSG00359418 (Port Of EnhancementRequest DCSG00421187)
-storcli "set good" command can still be used for JBOD EPD-PT drives.(DCSG00318591 (Port Of EnhancementRequest DCSG00353919)
-PERC11.1 - Dual x8 Support for 16 port Controllers.(DCSG00299060 (Port Of EnhancementRequest DCSG00323772)


007.1513.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------- 
MR 7.15

Defects:
-CLI Version info is seen in continuation of Sense data when executed show events.(DCSG00935802)
-Handling the read-only file system from storcli.(DCSG00938327 (Port Of Defect DCSG00542683))

Enhancements:
-Request to add checks (DevId, SubDevice Id) check prior to flashing.(DCSG00930193 (Port Of EnhancementRequest DCSG00500924))

007.1510.0000.0000  - Moderate Impact/Low Probability of Occurrence
-------------------- 
MR 7.15

Defects:
-From the CLI failed to convert UBAD state drive to UGOOD.(DCSG00391494)
-PH17 PA - StorCLI ARM - show file command displays incorrect output for BIOS image.(DCSG00320641 (Port Of Defect DCSG00315152))
-StorCLI listing failed NVMe drives in non-sorted order.(DCSG00321815 (Port Of Defect DCSG00320844)
-MR 7.16: Storcli: learnStartTime displayed incorrectly in command details.(DCSG00321908 (Port Of Defect DCSG00320649))
-rval - 0" is displayed for "show phyerrorcounters" command..(DCSG00337735 (Port Of Defect DCSG00337710))
-DiskGroup show all list Hostpare in Unconfigured drive list.(DCSG00360517 (Port Of Defect DCSG00359247))
-Controller Lane show command is not working with individual Lanes.(DCSG00386184 (Port Of Defect DCSG00386181))
-storcli /cx set flushwriteverify help needs an update.(DCSG00541982 (Port Of Defect DCSG00507067))
-"Failed Drive not found" reported from enclosure level show repair command.(DCSG00430578 (Port Of Defect DCSG00423496))
-Storcli show command is not displaying remaining drives when PD info fails for one drive.(DCSG00489855 (Port Of Defect DCSG00469639))
-Storcli /cx set debug reset all help description needs an update.(DCSG00538790 (Port Of Defect DCSG00521571))

EnhancementRequest:
-Display Enclosure serial No in Storcli.(DCSG00500922)
-IT Drive Model Number , Revision for SATA drives displayed in full.(DCSG00405900 (Port Of EnhancementRequest DCSG00371061))



007.1326.0000.0000  - Moderate Impact/Low Probability of Occurrence
-------------------- 
Defects:
-Foreign Config Preview shows empty data when Foreign config is present with Rebuild is in Progress.(DCSG00261203)
-Inconsist DG number in StorCLI.(DCSG00235157)
-RTTdump shows success but it fails to download the dump..(DCSG00253652 (Port Of Defect DCSG00253719))
-Incorrect Adapter type shown in the perccli show all output.(DCSG00241405 (Port Of Defect DCSG00244145))
-Expander firmware download using with mode 5 option fail with error message..(DCSG00239524 (Port Of Defect DCSG00240685))
-With length command, CLI says Memory Exhausted.(DCSG00235628 (Port Of Defect DCSG00236791))
-Enclosure position is showing as - for drive detailed properties on an IT controller.(DCSG00286693 (Port Of Defect DCSG00286701))
-Observe CLI Crash on windows while setting Autoconfig option.(DCSG00253642 (Port Of Defect DCSG00253722))
-MR7.15_storcli: With the latest storcli, VD creation with the remaining drives fails.(DCSG00278049 (Port Of Defect DCSG00282592))
-"No Controller found" shown when controller is busy..(DCSG00248017 (Port Of Defect DCSG00253661))
-On storcli /c0/v1,2,3,4 del if anyone of the vd in the series is not present then all the vd's are not deleted.(DCSG00264571 (Port Of Defect DCSG00266886))
-Connector Name is incorrectly displayed when connector count goes beyond 8.(DCSG00249023 (Port Of Defect DCSG00252701))
-MR 7.15: Storcli: Instance Validation Failed for "virtual-drive-config-schema.json" and "/call delete config force".(DCSG00247992 (Port Of Defect DCSG00253761))
-With new MR API changes, storcli shows failure while changing accesspolicy.(DCSG00257307 (Port Of Defect DCSG00258140))
-MR 7.15: Storcli: Instance Validation Failed for "enclosure-fw-download-schema.json" and "enclosure FW download" output..(DCSG00250066 (Port Of Defect DCSG00253733))
-Show expansion shows wrong output in presence of JBODs..(DCSG00247163 (Port Of Defect DCSG00252417))
-Enclosure position value not listed properly in show all command.(DCSG00254935 (Port Of Defect DCSG00256384))
-Drives connected to IT controller reports Shield Counter.(DCSG00244631 (Port Of Defect DCSG00266894))
-Expander firmware download help need to be corrected for IT controller..(DCSG00239870 (Port Of Defect DCSG00240680))

EnhancementRequests:
-To add return status MFI_STAT_OK_REBOOT_REQUIRED to MR_DCMD_LD_SET_PROPERTIES in mr.h.(DCSG00256271)
-Additional FDE type for Ruby SED support.(DCSG00055878)
-MFI SMP Port Num API changes.(DCSG00257777)
-MR7 API: Add package incompatibility reporting.(DCSG00231443)
-SMART Polling Improvement - API Changes.(DCSG00246317)
-Implement customSign.exe CLI wrapper utility to help customers sign with their private key.(DCSG00234646)
-Changes to support 16port connection to Expander with AeroIOC.(DCSG00254845)
-Updating storcli BST scripts to support new VBAS Auto BST procedure.(DCSG00282976 (Port Of EnhancementRequest DCSG00290359))

007.1325.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------  
MR 7.13
Fix issue:
DCSG00235157 - Inconsist DG number in StorCLI
Description:
Customer reported the DG/Array/Row is incorrect to get from storcli and it causes "insert" command failure. 

007.1324.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------  
MR 7.13

Defects:
-Storcli: Optl not mentioned in /call/dall show output..(DCSG00065740)
-Instance Validation Failed for "/call set smartpollinterval=300" and controller-smartpollinterval-schema.(DCSG00057141)
-StorCLI crash when create VD.(DCSG00052275)
-/e: and /s: is not mentioned in the Convention for /storcli64 /c0/v0 start migrate detailed ?.(DCSG00143788)
-BZ(186687):[AMD2P & Whitley] EXSi 7 can't boot up after install storcli.(DCSG00048516)
-Storcli show Device type as backplane while no drives are connected.(DCSG00074732)
-Help Description for Migrate shows "operation" printed twice in Storcli output..(DCSG00063696)
-Instance Validation Failed for "/call show" and controller-properties-schema.json.(DCSG00057213)
-Coverity analysis - Fixing uninitialized variables, resource leaks, and return statements - Part 1.(DCSG00046195)
-Foreign topology table display BT as "Y" for drives which are in foreign state..(DCSG00068453)
-Storcli: Same help description across "/c0/e0 show" and "/c0/e0 show all"..(DCSG00064748)
-While executing perccli, by default log file with storcli.log is getting generated..(DCSG00038031)
-MR 7.13: Storcli(Regression): Syntax error seen while using "nolog" and "page" together as parameters.(DCSG00071417)
-In Aero behind atlas configuration "NVME" drive firmware revision shows wrong.(DCSG00049614)
-Storclif command for battery retention test issues command to start retention test which is an unsupported command.(DCSG00058688)
-Show DPM with type LCT is not giving proper output and register DPM commands for all OS.(DCSG00033459)
-Storcli: ProdID Legend abbreviation missing in /c0/eall show output..(DCSG00063317)
-FW sometimes allows an invalid CLI command (set personality=HBA) to be successful and sets the personality to eHBA mode.(DCSG00129542)
-Fixing Coverity defects.(DCSG00044004)
-Unable to create JBOD using the legacy command with latest Perccli.(DCSG00118670)
-MR 7.13: Storcli: GHS is shown as revertible.(DCSG00065815)
-In the presence of Locked Foreign config, "/c0/fall del" shows incorrect output..(DCSG00062615)
-StorCLI - '/c0 show nolog' reported as Un-supported Command.(DCSG00071410)
-Set VD policy to WB (unsupported )should return failure in JBOD personality..(DCSG00076992)
-Shenandoah_MRSA: Enclosure Bay count coming Wrong in CLI.(DCSG00074731)
-Shenandoah_Storcli : Legend for ID in JBOD list is missing.(DCSG00069312)
-Incorrect Legend abbreviation in storcli show output.(DCSG00058874)
-MR 7.13: Storcli: controller add commands are listed along with vx commands..(DCSG00065744)
-Even on giving wrong 'storclif delete config' command syntax, the config is cleared successfully without any error.(DCSG00055164)
-Storcli.efi shows incorrect note for unsupported commands for MR controllers.(DCSG00056335)
-VMware peccli, percli64 and storcli64 bit binary loads library from storcli 32 bit's installation path.(DCSG00074600)
-StorCLI - /c0/eall/sall start locate not working for second enclosure connected.(DCSG00040244)
-Instance Validation Failed for "/call show dpm" and controller-dpm-schema.json.(DCSG00057194)
-Command description should be modified for storclif /cx set activityforlocate=<on|off>.(DCSG00069746)
-MR 7.13: Storcli: bbu not described in convention details.(DCSG00066314)
-Shenandoah_storCLI: Add vd command for r0 getting successful with 512KB when mazStripeSize is 1MB.(DCSG00057003)
-Fixing Coverity defects, uninitialized, unused variables and memory leaks.(DCSG00052049)
-Start_entry is not a command parameter in show events command.(DCSG00067937)
-On OS /cx/dall split mirror command shows success when there is no drive groups.(DCSG00069690)
-Update the storcli readme with for Esxi 6.x and Esxi 7.0 releases.(DCSG00055533)
-Extended the abbreviation in the legends.(DCSG00069703)
-Shenandoah : storcli : Energy Pack show present for MR 216i controller , where the hardware is not supported.(DCSG00053888)
-"set sbr" command mentioned in detailed help but not listed in help output..(DCSG00068444)
-Creation of VD for with more than 64 drives is failing with "Cannot create configuration with x drives".(DCSG00056544)
-Description of compare firmware ver command does not mention as IT supported command.(DCSG00070258)
-Command description should be modified for /cx set alarm command.(DCSG00069709)
-MR 7.13 : RSOD is seen for storcli.efi show command when the controller is in invalid state.(DCSG00066879)
-StorCLI /cx restart is not supported in UEFI environment should be mentioned in help..(DCSG00068879)
-Remove deprecated command 'show adpcount' from Ubuntu folder(readme).(DCSG00058329)
-Segmentation fault seen while running OCR and Patrol read in loop on ESXi7.0 OS..(DCSG00066854)
-Instance Validation Failed for "/call/fall import preview" and foreign-configuration-detailed-schema.json.(DCSG00068868)
-Field for CV is missing in table as well as in legend for storcli64.exe show command.(DCSG00067075)
-Restrict discovery of PERC HBA through StorCLI(Static binary).(DCSG00077037)
-PH14 Alpha Aero - StorCLI - Difference in output noted for /cx/px set state command.(DCSG00055119)
-MR 7.13 : Enclosure Device ID is mentioned in the legend for /cx/vall show command.(DCSG00067878)
-MR 7.13 : Cosmetic issue is seen in the command name of /cx /cx show memscrubpatterns ?.(DCSG00067877)
-Commands displayed twice in help description..(DCSG00068441)
-Storcli DPM does not use legend "Resp" in EXT output.(DCSG00060706)
-Enclosure ID is not mentioned as optional in "add Vd " command.(DCSG00058867)
-Port information coming as internal and Location as Blank in when all the drives are removed from UBM2 Backplane.(DCSG00071756)
-DPM delete help is listed under drive delete command group.(DCSG00053537)
-No mention on convention in restart command description..(DCSG00068542)
-Fixing Coverity defects - Uninitialized variable, resource leaks and null referencing.(DCSG00041202)
-Set the PR to run on only configured array, but it complete the PR along with un-configured area..(DCSG00067103)
-Fixing Coverity issues - Resource leaks.(DCSG00054690)
-Storcli throws incorrect error message for /c0 add vd each r0 when Ubad drive is present in the setup..(DCSG00069698)
-Use NVRAM to save PTB information -- API changes.(DCSG00082981)
-Debug logs in FreeBSD is logging timestamp in different lines.(DCSG00069730)
-"/c0 show nolog" shows as "un-supported command.(DCSG00068482)
-Shenandoah_Storcli : The status of PD FW update on multiple drives is not proper when parallel is not included.(DCSG00069693)
-Device type of UBM backplane is displayed as expander in Valvano-32i Controller managed port(C3)..(DCSG00054275)
-Shenandoah_PA2:StorCLI not branding compliant for VD creation command Failure case -IO Policy specif.(DCSG00049610)
-Storcli: px is not described in convention details..(DCSG00065742)
-Unmap enabled not listed for unmap enabled VDs with /cx/vall show all cli command.(DCSG00112331)
-Instance Validation Failed for "storcli64.exe show" and system-schema.json.(DCSG00057156)
-Not able to create R1/R10 with 1MB size and strip size is 1MB.(DCSG00058162)
-Description for storcli output is not proper after collecting the snapdump with id=all.(DCSG00063626)
-StorCLI not reporting default oob settings from nvdata value.(DCSG00066530)
-Executing storcli commands from external path throws error.(DCSG00072117)
-StorCLI: /storcli /cx add vd verbose help ,strip size 512 is missing in help description under strip sizes..(DCSG00146343)
-MR 7.13: Storcli: Caution mentioned instead of note..(DCSG00066554)
-perccli is Reporting incorrect scheduled BBU Learn Date.(DCSG00109638)
-Coverity analysis - Fixing uninitialized variables, resource leaks, and return statements.(DCSG00046460)
-Storcli64.exe /c0 show freespace shows unnecessary data when freespace is not present.(DCSG00055686)
-Schema mapping list is not updated with DPM commands.(DCSG00057823)
-Foreign DHS drive state is displayed as UGood under /c1/fall show all tab..(DCSG00068427)
-MR 7.13: Storcli: logfile is not described in show dpmstat command..(DCSG00065838)
-Statistics is spelled as Statitics in dpm stat commands.(DCSG00057112)
-Cache Vault should be placed instead of battery for "storcli /cx/cv show status ?" help.(DCSG00143868)
-Exit code showing "0" for failed storCLI command due to syntax error.(DCSG00054313)
-Removal of log type from storcli logs.(DCSG00046794)
-Discription for the term "NoVDs" is missing in the legends.(DCSG00068592)
-start dpm returned error.(DCSG00035436)
-Storcli: Show latest events output print shows 0.00 for all the number of events dumped (expected is the number of events queried for).(DCSG00068877)
-Incorrect message noted when Ventura firmware flashed on Aero board.(DCSG00046031)
-No consistency in the help details of "/c0/ex download" commands.(DCSG00064745)
-Storcli license file is not present in the Vmware, Ubuntu & EFI folders.(DCSG00056538)
-Storcli issuing 'add vd r0 drives=all' causes storcli to crash.(DCSG00053963)
-No syntax error for multiple usage of "nolog" parameter in the command..(DCSG00066729)
-Re-Host information is blank when ASO is not enabled.(DCSG00072628)
-SSD Wear guage Parameter "SSD Percent used" to be removed from CLI.(DCSG00074791)
-MR 7.13: Storcli: sx not described in convention details..(DCSG00066310)
-Error message is improper for invalid raid level in volume creation.(DCSG00081057 (Port Of Defect DCSG00083789))
-Set MFG command does not throw an error when executed with empty file..(DCSG00074178 (Port Of Defect DCSG00074209))
-VD delete command works with multiple force options.(DCSG00165527 (Port Of Defect DCSG00167329))
-Syntax error for /c0 show AliLog ?.(DCSG00109790 (Port Of Defect DCSG00112470))
-storcli faults when issue drive poh command on Linux.(DCSG00075870 (Port Of Defect DCSG00075875))
-show memscrubpatterns shows status as success but failed in the description.(DCSG00077082 (Port Of Defect DCSG00103214))
-PH15 PA StorCLI - Segmentation fault observed when Sea IT PSOC image flashed on Ventura.(DCSG00075626 (Port Of Defect DCSG00212680))
-Wrong enclosure details are displayed when slot details are queried..(DCSG00127133 (Port Of Defect DCSG00139981))
-Storcli_VMWare gives failure messages when user tries to set the lanespeed.(DCSG00167210 (Port Of Defect DCSG00167280))
-"Download cpld" command displays incorrect output for MR controller..(DCSG00075734 (Port Of Defect DCSG00075863))
-The properties displayed in the command show htbparams has misspelled fields.(DCSG00104056 (Port Of Defect DCSG00105681))
-Instance Validation Failed for "/call/fall show" and foreign-configuration-schema.json.(DCSG00076415 (Port Of Defect DCSG00078173))
-storclif.exe /cx set copyback ? shows incorrect command name..(DCSG00075718 (Port Of Defect DCSG00075890))
-No description mentioned for "/cx set eghs" command..(DCSG00074290 (Port Of Defect DCSG00074768))
-Unified StorCLI Phase 15: storcli64 /cx add vd each help file missing options and format inconsistencies.(DCSG00139659 (Port Of Defect DCSG00139995))
-Aero Controller DPM does not report Max Response Time under 1 ms..(DCSG00099365 (Port Of Defect DCSG00102548))
-Storcli: Wrcache is mentioned instead of WT| WB.(DCSG00074284 (Port Of Defect DCSG00074767))
-Storclif allows to set Set SubOEMID as 1000 and more.(DCSG00079932 (Port Of Defect DCSG00080836))
-Description for storcli output is not proper after collecting the snapdump with id=all.(DCSG00031711 (Port Of Defect DCSG00063602))
-Storcli /cx show cc , does not shows the "Unit" for CC execution Delay..(DCSG00126229 (Port Of Defect DCSG00129753))
-storcli64.exe /c0/e1/s1 start sanitize throws syntax error..(DCSG00129738 (Port Of Defect DCSG00129750))
-forcehcb is executed with incorrect description in OS level..(DCSG00080961 (Port Of Defect DCSG00083295))
-"Show alilog" command output shows invalid PD ID in Virtual drive info..(DCSG00167354 (Port Of Defect DCSG00167449)
-force is not defined under OPTIONS in storcli64 secureerase help file.(DCSG00148255 (Port Of Defect DCSG00150480))
-Storcli displays "Returned SCSI status for the command : Check condition" along with regular command.(DCSG00138580 (Port Of Defect DCSG00139200)
-Aero Alpha: Storcli stops functioning during run of attached script.(DCSG00034379 (Port Of Defect DCSG00039682)
-/vx is mentioned in the convention for storclif64.exe /cx set cc detailed ?.(DCSG00075700 (Port Of Defect DCSG00075894))
-DCSG00096587.(DCSG00104055 (Port Of Defect DCSG00108742))
-Avenger: ./storcli2 /c0 show ds all command(not present) shows the output of /c0 show all.(DCSG00061163 (Port Of Defect DCSG00080485)
-PATH_1 and PATH_BOTH assigned drives not getting displayed under storcli in WF DDROCK setup.(DCSG00050891 (Port Of Defect DCSG00079275))
-Storcli output starts with "GetCtrlInfo : ProcessLibCommand failed; retCode = 0xFF" for all command.(DCSG00214170 (Port Of Defect DCSG00214248))
-"OS Drive Name" does not display the details in "vall show all" for esxi OS.(DCSG00102559 (Port Of Defect DCSG00103190))
-Storcli: "show bbmt" displays output for an invalid VD..(DCSG00228667 (Port Of Defect DCSG00230346))
-Storcli command description shows none for Download firmware failure.(DCSG00221431 (Port Of Defect DCSG00223281))
-Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json.(DCSG00132488 (Port Of Defect DCSG00137828))
-NoVDs is displayed in dall show output..(DCSG00074628 (Port Of Defect DCSG00074763))
-"reset errorcounters" command mentions options under conventions.(DCSG00074288 (Port Of Defect DCSG00074764))
-PH16 PA - StorCLI - Compare fwprodid help page needs to be updated.(DCSG00167732 (Port Of Defect DCSG00215133))
-Display basic secure boot details for Sea IT controller.(DCSG00074184 (Port Of Defect DCSG00074218))
-No consistency in the description of Force option.(DCSG00074283 (Port Of Defect DCSG00074765))
-Storcli /c0/eall show status extended command fails to generate any output for ARM server backpla.(DCSG00146359 (Port Of Defect DCSG00150479))
-Debug log configuration file for perccli is taking storcliconf.ini.(DCSG00074691 (Port Of Defect DCSG00074757))
-Compare fwprodid command fails for 9500-16i.(DCSG00092943 (Port Of Defect DCSG00115266))
-Handling of controller properties related to drive FW download.(DCSG00138192 (Port Of Defect DCSG00139266))
-In command storcli /cx/ex/sx show DPM type=Ext , Sectors Read (Written) is not displayed correctly.(DCSG00083167 (Port Of Defect DCSG00103210))
-Ph16 PA: Storcli crash observed while running show all with NVMe drives connected.(DCSG00150686 (Port Of Defect DCSG00167881))
-Description for "profileid=<id>" is missing in help and detailed help.(DCSG00152251 (Port Of Defect DCSG00152935))
-EKMS Boot Agent Status is not updating properly..(DCSG00049004 (Port Of Defect DCSG00050289))
-MR 7.15: Storcli: Force option is mentioned as "For".(DCSG00223195 (Port Of Defect DCSG00225259))
-Storcli displays 255 max spin-up drive count in help description instead of 240.(DCSG00098081 (Port Of Defect DCSG00108741))
-"Compare factorysettings" command displays incorrect output for wrong input file.(DCSG00075762 (Port Of Defect DCSG00075888))
-Storcli64 /cx show spinupdrivecount help file description needs update.(DCSG00150052 (Port Of Defect DCSG00150459)
-Segmentation with controller show summary command when controller is in unsupported state.(DCSG00215109 (Port Of Defect DCSG00215118))
-StorCLI show autoconfig does not display all properties it can set.(DCSG00071834 (Port Of Defect DCSG00080859))
-Storcli returns wrong Operating system in Windows..(DCSG00037088 (Port Of Defect DCSG00037336))
-No description for "set autoconfig=R0 immediate" command..(DCSG00129610 (Port Of Defect DCSG00129762))
-Displaying connected portnumber as per API supportMoreThan16Phys.(DCSG00104331 (Port Of Defect DCSG00108740))
-Compare Factory command execution fails in storclif.(DCSG00074182 (Port Of Defect DCSG00074207))

EnhancementRequests:
-HPE : Windows and Linux StorCLI signing.(DCSG00053511)
-Implement changes to secureSign signing tool and infrastructure to support mixed list of PublicKeys that are from SCGCQ and DCSG..(DCSG00105430)
-API change to support ISE completion status.(DCSG00065881)
-MR API: Change event class for SPDM events.(DCSG00134416)
-API change to add DCMD MR_DCMD_CTRL_LOCK_KEY_SECRET_KEY_APPLY and associated MFI.(DCSG00222915)
-Perccli: Need a mechanism to get supported device protocols for each controller form factor.(DCSG00117742)
-support for sanitize command.(DCSG00108999)
-Shenandoah: Support for the New Energy Pack states.(DCSG00043240)
-Preboot Trace Buffer [PTB] for Ventura/Aero - MR API.(DCSG00060713)
-Remove Help Text for lanespeed commands.(DCSG00099939)
-Shenandoah: Change the CLI installation Directory name from Megaraid to hpe.(DCSG00053988)
-Porting storcli source from V8 Clearcase to CC9 GCP database.(DCSG00013486)
-Creating VD with 0 MB or GB should not be allowed to succeed --ve case boundary value scenario.(DCSG00048859)
-MR API: NVME Drive Init Error Report and Repair for Aero/Ventura.(DCSG00071534)
-DCSG00129388
-Support to display drive connector name information for SAS3.5 IT Controllers.(DCSG00120994)
-Add segment area into pci information of Megaraid controller in storcli.(DCSG00032694)
-Populate secureboot properties "KeyUpdatePending" and "Remaining Secure Boot Key slots" in StorCLI.(DCSG00101684)
-Remove (hide) PCIe Link form in HII and from CLI for Perc11.(DCSG00077856)
-Define MR_SAS_PHY_CONNECTION.currentSpeed when no devices are connected.(DCSG00071066)
-Signing Linux executables via GPG method in HSM.(DCSG00077215)
-Shenandoah: Creating VD with 0 MB or GB should not be allowed to succeed - Part 2.(DCSG00053587)
-Shenandoah: SSD Wear Gauage.(DCSG00046064)
-MR API changes - Support new DCMD for Platform Security SPDM.(DCSG00068355)
-Add /px linkspeed back to help text.(DCSG00126913)
-HSW Applications to not send close DCMD as the first command to perform Firmware update.(DCSG00055146)
-Update/remove Snapdump save count field in show snapdump command based on FW support.(DCSG00038800)
-Include new field cannotSetMode in MR_AUTO_CFG_PARAMETER structure..(DCSG00072780)
-API changes to expose MR_AUTO_CFG_PARAMETER for NONE mode.(DCSG00151058)
-Add new security events.(DCSG00167313)
-Request for DPMstat support in MegaRAID SAS 3.5 controllers in storcli.(DCSG00032273)
-MR API: update field in event structure..(DCSG00093331)
-Preboot Trace Buffer [PTB] for Ventura/Aero - add a switch - MR API.(DCSG00226286)
-SMART Polling Improvement- API Changes.(DCSG00214352)
-References to MR_ENCL_LIST and MR_ENCL_LIST_EXT should be based on the support bit.(DCSG00037323)
-Shenandoah: Type 2 Back plane Support for StorCLI.(DCSG00054795)
-StorCLI: Implementing span depth logic and pd per array count for RAID 10.(DCSG00049781)
-Updating BST scripts to support auto BST through VBAS in clear case version 9.(DCSG00050763)
-FW SAS MEGA API:Change MR_EVT_CTRL_FLASH_DISALLOWED_SB_KEY_CHANGE_PENDING event.(DCSG00086780)
-Revert the CLI Help Text for backwards compatibility to include Dimmer Switch 3.(DCSG00068659)
-Shenandoah: Reverting back the changes made for Span setting for RAID 1 & 10.(DCSG00073393)
-New MFI Stat for the updated recon behavior.(DCSG00229416)
-Shenandoah: Remove Span setting for RAID 1 & 10.(DCSG00043198)
-Restore Factory Default doesn't prompt user to reboot the system after being performed.(DCSG00122000)
-MR API changes - Support new Provisional bit in CTRL INFO and new MFI status for Platform Security.(DCSG00106380)
-Add support for signing MegaRAID Legacy BIOS CU Images (CTLR) images.(DCSG00143847)
-Phase 14 : StorCLI should provide power cycle message post erase all command is executed.(DCSG00039542)
-Enhancement of Enclosure MultiPath algorithm in storcli.(DCSG00075191 (Port Of EnhancementRequest DCSG00079538))
-Support to generate storcli static library.(DCSG00075265 (Port Of EnhancementRequest DCSG00075687)
-Updating toolchain for VMware7.0 GA.(DCSG00134764 (Port Of EnhancementRequest DCSG00136269))


007.1212.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------
MR 7.12

Defects:
StorCLI should refer to MR_PD_INFO.properties.ISECapable to display "Cryptographic Erase Capable" field - Revert of SCG(DCSG00014660)
Making the Predictivefaliure  check OEM specific in controller health algorithm(DCSG00014971)
HBA345_Dev_UT: Enclosure position value in perccli is same for both front and rear BP's(DCSG00033180
Cisco - CSCVr89052 - PATH_1 and PATH_BOTH assigned drives not getting displayed under storcli in WF DDROCK setup(DCSG00050891)
StorCLI Point release RO DCSG00079546 - Windows binaries are missing from the RO(DCSG00081022)
<Regression> StorCLI 7.10 point release  - /cx erase help not listing all supported commands(DCSG00081294)
StorCLI 7.10 point release - Update license files to RO DCSG00079546(DCSG00081298)
Removal of unsupported phy commands on IT3 controller(DCSG00025416)
Phase 12 - Oct Huawei DET - New PD FW Not Updated After Flashing PD FW (NVMe)(DCSG00015875)
MR_6.14_Huawei: OnDemand Snapdump in Windows gives failure message "RTTdump Feature not supported"(DCSG00020717)
help is not proper for show events and set copyback commands(DCSG00005503)
MR 7.12: Storcli: Instance Validation Failed for "/call show all" and controller-detailed-properties-schema(DCSG00006331)
MR 7.12: Storcli: Instance Validation Failed for "/call/pall show all" and controller-phyerrorcounters-schema(DCSG00006853)
Orion PA9 : Convention comes in same line while performing help for /c0/e0/s0 download.(DCSG00008084)
MR_7.12_Storcli: Xenserver8: "Core dumped" while executing "/call/eall show all" and "/call/eall/sall show all"(DCSG00009400)
Aero DBU PA7 : Init is in progress error message is thrown by Storcli for start migrate command when VD erase is in pro(DCSG00012344)
Orion PA9 : Storcli version mismatch as compared in storcli -v and storcli properties(DCSG00014485)
Orion PA9 : Storcli crashes while performing storcli /c0 show(DCSG00014486)
Storcli show all cmd displaying "AVAGO" in scheduled tasks info(DCSG00014580)
Aero DBU PA7 : Storcli displays multiple error messages when user enters incorrect device ID during migrate operation.(DCSG00014644)
Fixing Coverity defects - resource leaks and null referencing(DCSG00015721)
Correcting the detailed help syntax(DCSG00016268)
MR7.12 StorCLI: Ouptput message Description wrong for StorCLI VD policy change from WT -WB(DCSG00016372)
StorCLI:  Fixing coverity defects and adding debug statement(DCSG00019683)
perccli windows binary property page has storcli references(DCSG00019800)
Aero DBU Alpha : Storcli displays incorrect error message for "add vd each r0" command when SED drive is connected in t(DCSG00019816)
Application Exit code is always success for UEFI StorCLI(DCSG00020670)
MR 7.12 LSA "instant secure erase" is not found in storcli as cli use secureerase(DCSG00022096)
Help content for Drive Init is not showing it as Clear operation(DCSG00022893)
MR7.12_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend(DCSG00022942)
MR 7.12: Storcli: Instance Validation Failed for "/call start Diag Duration=40" and controller-diag-schema(DCSG00023543)
MR 7.12: Storcli: Instance Validation Failed for "/call show linkconfig " and controller-linkconfig-schema(DCSG00023545)
Aero Alpha : Storcli throw Segmentation Fault in Driver load error handing path -(DCSG00024554)
MR 7.12_Storcli: On ARM server the latest storcli Vendor,Licenses,URL and distribution shows as "AVAGO Technologies"(DCSG00025885)
Aero DBU Alpha - Scheduling is displayed as Schedulling under "/cx set pr ? " command description(DCSG00027203)
Add warning/recommendation messages for changing lane speeds(DCSG00027869)
Orion MR : Description for storcli output is not proper after collecting the snapdump with id=all(DCSG00031711)
Aero Alpha: Storcli stops functioning during run of attached script(DCSG00034379)
Storcli returns wrong Operating system in Windows.(DCSG00037088)
MR 7.12_Storcli: The latest storcli vmware build reference URL shows "http://www.lsi.com"(DCSG00039104)
MR 7.12_Storcli: The latest storcli vmware build 007.1209.0000.0000 shows older package version(DCSG00039112)
PERC 11:EKMS:PKG 2973: EKMS Boot Agent Status is not updating properly.(DCSG00049004)
PH13 StorCLI PA - Update help section about 'nolog' option(DCSG00002975)
PH13 PA - StorCLI - Incorrect message for /call/pall show all command(DCSG00003003)
StorCLI_7.12_Ph13:Phyreset Fails on IT controllers(DCSG00005488)
PH13 PA - StorCLI - NVMe drive linkspeed not seen with /cx/pall show(DCSG00009522)
With IT controller for set or reset with invalid phy is not showing error(DCSG00010226)
Aero_storecli:Using latest storecli Firmware product id parameter value fail to display.(DCSG00011446)
MR_7.12: Storcli: Segmentation Fault for "storcli64 page"(DCSG00012563)
Storcli ph13: Fixing array size for function DEBUG_LOG(DCSG00014665)
Aero Orion IT:- Mismatched phy info listed for 440-16e/440-16i(DCSG00023320)
Enclosure position value in storcli is same for both front and rear BP's(DCSG00031302)
Misleading error message when create unmap VD with storcli64.exe /c0 add vd each r0 unmap using unmap and non-unmap PDs(SCGCQ02059720)
StorCLI: Debug prints enabled in latest Phase 12 PA storCLI.efi image(SCGCQ02097317)
Json Schema for the command "storcli /cx/ex show phyerrorcounters" needs to be updated(SCGCQ02101372)
MR 7.11: Storcli: Instance Validation Failed for "/call show all" and system-schema.json(SCGCQ02112192)
DBU Aero PA4 : Cosmetic error is seen in command description for Show SSDThermalPollInterval ?(SCGCQ02124673)
Aero A0 PA4: "Storcli /c# set jbod=on" shows success but does nothing(SCGCQ02117219)
Aero (DBU PA4):Storcli: Junk character in PD start locate command description.(SCGCQ02125654)
Phyreset Fails on IT controllers and update help(SCGCQ02169242)
Drive mode-e fw download with activatenow is not working(SCGCQ02142068)
MR 7.11: Storcli: Instance Validation Failed for "/call/eall show status extended" and enclosure-status-extended-schema.json(SCGCQ02150924)
MR7.11_Storcli: Incorrect error description while creating r1 with single drive(SCGCQ02165933)
Phase 12 - Oct Huawei DET - "./storcli64 /c0/pall show" Command Fails With "Null pointer exception"(SCGCQ02175414)
Phase 16 (IR) - Oct Huawei DET - Unsupported Drive State is Displayed for "./storcli /c0 show" Command(SCGCQ02170389)
MR 7.11 - Oct Huawei DET - Nomenclature Issue for "rbld=Rebuild" In Storcli Show Help Menu for SAS3516(SCGCQ02170197)
Usage of 64 bit address instead of 32bit address while sending commands to FW in uEFI driver less environment(SCGCQ02174934)
MR_7.10_Storcli: Storcli displays incorrect error message for unmap VD creation with regular HDD drives.(SCGCQ02019751)
PH12 PA - StorCLI crashes when call/pall show executed with SAS3 & Ventura boards(SCGCQ02103217)
PH12 PA - StorCLI - Debug StorCLI binary is placed in both places of EFI dir RO SCGCQ02085693(SCGCQ02091140)
PH12 PA - Update readme file in VMwareOP64 folder in accordance with PR SCGCQ01923533(SCGCQ02108550)
MR 7.11: Storcli.efi: In ARM server UEFI shell, storcli.efi hangs forever when storcliconf.ini is present(SCGCQ02115036)
Aero (DBU PA4):Storcli:  VD legend is missing in "/call/vall show expansion" command.(SCGCQ02124508)
Aero DBU PA4 : storclif /cx show configautobalance  ? help output shows the name as "show NCQ"(SCGCQ02124632)
Configuring multiple lane speed is working only for fisrt ID, Rest were ignored(SCGCQ02136333)
Aero (DBU PA5):Storcli: Storcli: "/c0 set patrolread ?" lists detailed help and snapdump rttdump is mentioned as optional.(SCGCQ02140873)
MR 7.11: Storcli: Instance Validation Failed for "/call/eall show status" and enclosure-status-schema.json(SCGCQ02150921)
Aero (DBU PA5):Storcli: Force is not mentioned as key word in "/cx/vx del" error message.(SCGCQ02142017)
MR7.11_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend(SCGCQ02165944)
Aero (DBU PA5):Storcli: "Ctrl" legend not mentioned.(SCGCQ02146822)
MR7.11_Storcli: storcli set securitykey detailed help does not show description for all the options(SCGCQ02096732)
MR7.11_Storcli: storcli show output shows UBUnsp as UBad Unsupported where as UGUnsp just Unsupported(SCGCQ02096722)
Aero IT - PA3 - StorCLI crashes for 'storcli J command(SCGCQ02117749)
Lenovo Orion IT:- Command to flash UEFI on Aero/sea HBA from storcli/scrutiny fails(SCGCQ02137751)
Flashing of Completeflash fails on Sea IT controller(SCGCQ02139780)
StorCLI: Fixing coverity defects(SCGCQ02123769)
MR 7.11: Storcli: Instance Validation Failed for /call/show_smartpollinterval.json and controller-smartpollinterval-schema.js(SCGCQ02135516)
DBU PA5 Aero : Background operations keep on progressing after hitting /c0 shutdown from storcli(SCGCQ02132024)
Aero (DBU PA5):Storcli: No "Rbld" legend during rebuild.M(SCGCQ02146819)
complete Lane WWID is not displayed(SCGCQ02145716)
Convention comes in same line while performing help for /c0/e0/s0 download.(SCGCQ02176681)
Adding missing syntax for the command deviceorderbyfirmware(SCGCQ02121705)
MR 7.11: Storcli: Instance Validation Failed for "/call/vall show unmap" and vd-unmap-schema.json.(SCGCQ02113316)
Aero (DBU PA5):Storcli: "completeflash" is listed in Windows help file.(SCGCQ02141931)
Aero (DBU PA5):Storcli: Force option not mentioned in "/cx/dx add mirror" and "/cx/vx start init" command.(SCGCQ02140878)
Force option is needed only for Parallel Drive microcode update, but it allows to take for normal also(SCGCQ02177086)
StorCLI Copyright Notice Needs to be updated(SCGCQ02174040)
Wrong error message when create unmap VD with unmap disable on controller(SCGCQ02064118)
Aero DBU PA4 : storclif /cx delete colinfo  ? shows syntax error(SCGCQ02124492)
MR 7.11: Storcli: Instance Validation Failed for "/call show" and controller-properties-schema.json.(SCGCQ02108770)
PH12 PA - StorCLI version not getting printed for show file command(SCGCQ02105185)
Aero DBU PA4 : Command name shown in help output differs for storclif.efi /cx show limitmaxrateSATA ?(SCGCQ02124667)
Aero DBU PA4 : Redundant information is displayed for set driveactivityled command in storclif.(SCGCQ02124675)
Aero (DBU PA4):Storcli: Wrong reference of "page=[X]" as part of syntax error message.(SCGCQ02124252)
Aero DBU PA4 : storclif.efi /cx show deviceorderbyfirmware ? throws syntax error.(SCGCQ02124528)
MR 7.11: Storcli: Instance Validation Failed for /call/show_consistencycheck.json and controller-cc-schema.json(SCGCQ02135510)
Phase12-Storcli- In Windows storcli64.exe /c0 show htbparams is showing random values for SAS3 controller(SCGCQ02125598)
Aero (DBU PA5):Storcli: No description of patrolread "OFF" and optional is mentioned as {}.(SCGCQ02140859)
PH12 BETA - /cx erase help not listing all commands(SCGCQ02146466)
Aero (DBU PA5):Storcli: No consistency in the usage of "|" in the command such as "on|off".(SCGCQ02142022)
Phase 12 - Oct Huawei DET - Delay Option In PD Download Operation is Not Honored(SCGCQ02176690)
With IT controller for set or reset with invalid phy is not showing error(SCGCQ02181823)
Updating phy link reset logic for IT cards with respect to storelib changes(SCGCQ02184862)
Drives connected to active backplanes not showing the phy info in connector name(SCGCQ02112424)
PH12 PA - StorCLI - 9310-8i IR FW download fails(SCGCQ02121783)
MR 7.11: Storcli.efi: On ARM server, incomplete configuration data received error is observed for any storcli.efi command(SCGCQ02114898)
Aero PA6 - storcli snapdump id=x errors without optional file parameter(SCGCQ02161748)
PH11 - StorCLI - Incorrect message for /call/pall show all command(SCGCQ02169536)
cli does not allow  to do crypto erase on SATA SSD.(SCGCQ02147075)
MR7.11_Storcli: Storcli stop erase needs an help file update(SCGCQ02168895)
Phase 12 - Oct Huawei DET - Incorrect Help Menu For "show phyerrorcounters"(SCGCQ02180495)
Phase 12 - Oct Huawei DET - New PD FW Not Updated After Flashing PD FW (NVMe)(SCGCQ02191421)
Aero PA4 DBU : Storclif doesn't show details for VF/PF in help file for vfmap command .(SCGCQ02123789)
Aero (DBU PA4):Storcli: Typo in /c0 add vd detailed help.(SCGCQ02119091)
Aero (DBU PA4):Storcli: /c0 compare lists /c0/px compare command.(SCGCQ02124246)
StorCLI: Fixing coverity issue in libmod(SCGCQ02123790)
SWR:Storcli: "Show" and "show all" output Description is shown as "No Enclosures found"(SCGCQ02146814)
MR 7.11 storcli -help missing the verbose option(SCGCQ02158600)
Phase 12 - Oct Huawei DET - PD FW Download is failing for Mode f(SCGCQ02168197)
PH12 PA - StorCLI - Incorrect string displayed with show command in FreeBSD 11.2(SCGCQ02094529)
PH12 PA - StorCLI /cx/pall show fails on 9400-8e board(SCGCQ02119004)
MR 7.11: Storcli: Instance Validation Failed for "/call/v5 set bootdrive=off" andcontroller-bootdrive-schema.json.(SCGCQ02115786)
StorCLI: Fixing coverity defects for second run(SCGCQ02125523)
MR 7.11: Storcli: Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json(SCGCQ02135526)
Aero (DBU PA5):Storcli: /c0 set ? lists bbu,mx,px and lnx commands.(SCGCQ02136689)
Aero DBU PA4 : Storclif should not display vendor name in storclif.efi  /cx/ex download help command(SCGCQ02123765)
Aero (DBU PA5):Storcli: Improper spacing for the linkspeed description and "YY" parameter leads to confusion.(SCGCQ02139910)
MR 7.11: Storcli: Instance Validation Failed for /call/show.json and controller-properties-schema.json(SCGCQ02135420)
MR 6.14 - Oct Huawei DET - "Rbld=Rebuild" is Not Available In Storcli Show Help Menu for SAS3108(SCGCQ02170181)
MR 7.11: Storcli: Instance Validation Failed for "/call/cv show all" and cache-vault-detailed-schema.json(SCGCQ02150651)
Aero (DBU PA5):Storcli: Help notes needs an update.(SCGCQ02146823)
Phase 12 - Oct Huawei DET - Incorrect Status for PD FW Download (Ventura IT)(SCGCQ02173203)
Phase 12 - Oct Huawei DET - Incorrect Phy Details Displayed for Ventura IT Controller(SCGCQ02174296)
	
Enchancement:
To bring MR 7.10 storcli change to CC9 GCP database(DCSG00013486)
Support to generate storcli static library(DCSG00075265)
Bring MR 7.11 storcli change to CC9 GCP database(DCSG00014492)
Updating the Makefile and projects as per new CC/CQ changes(DCSG00003002)
Updating the Json Schema files with respect to the latest code(DCSG00007394)
Controller commands Json Schema files update as per the latest code(DCSG00007435)
Schema validation : Schema update for VD/DG/Foreign related commands(DCSG00007453)
Add UEFI Shell StorCLI support for 64-bit Ventura Gen MR Legacy Boot solutions (solutions without UEFI driver)(DCSG00008200)
Changing the CBB download image type as per new MR API(DCSG00010253)
Migrating StorCLI's 64 bit VMware toolchain to 6.8.7-13394445(DCSG00014503)
PERC 11: Provide ability to expose SEP to host and disable PERC SES management in PercCLI / HII(DCSG00015020)
Supporting build and BST process through VBAS in Clear Case version 9(DCSG00024818)
Windows and Linux StorCLI HSM based signing support(DCSG00031618)
StorCLI PH13: Adding interface for lane display and configuration command for IT controllers.(DCSG00007909)
Atlas Support on Aero-IT(DCSG00008038)
Concern for security key passed in from storcli to be read in process data(SCGCQ02066380)
Support FMP Images in UEFI Version of PERCCli(SCGCQ02078649)
Add segment area into pci information of Megaraid controller in Storlib and storcli(SCGCQ02201178)
Create DVT / PVT PnP IDs for Cisco Pismo Beach card(SCGCQ02108965)
Return pended IOCTLS that was not completed after some numbers of OCRs had been initiated.(SCGCQ02066395)
Enable SnapDump for iMR(SCGCQ02208421)
HDET: Support in storCLI support PD firmware download for 3008IR/3008IT controllers(SCGCQ02160016)
multi VSES implementation(SCGCQ02066438)
Return pended IOCTLS that was not completed after some numbers of OCRs had been initiated.(SCGCQ02066399)
Add displaying list of enclosures in controller show and show all command(SCGCQ02124566)
LibMod changes : MR: 64 Bit  Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02085102)
SAS 3_5 Ventura family UEFI NVMe drive serial number issue(SCGCQ02074657)
Unmap error message changes as per new description in MR API(SCGCQ02115017)
MR: 64 Bit  Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02066386)
Lenovo Whitley/Orion - Addendum 7 - Lenovo request to support StorCLI & LSA for Valvano 28i (MR+Cub) and Custom Form Factor(SCGCQ02082612)


007.1022.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

Defects :
 - PERCcli Help text is missing description for "Lane Information"(SCGCQ02150899) 
 - Add NVMe width comments to mr.h(SCGCQ02146846) 
 - Fix API changes done for NVMe readiness(SCGCQ02142981) 
 - CLI returns "success" when attempting to set DS3 or DS4 to enabled(SCGCQ02116380) 
 - CLI returns "success" when attempting to change the H840 controler to eHBA personality.(SCGCQ02114332) 
 - CLI returns wrong error code upon failure(SCGCQ02084966) 
 - HPE shenandoah: storcli crashes during show command when DGs present(SCGCQ02065695) 
 - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02045324) 
 - ROP version not displayed with latest ROP version SCGCQ02035462(SCGCQ02041094) 
 - FW flash fails to load the latest image after upgrade downgrade with resetnow option(SCGCQ02035152) 
 - retentiontest command is successfully triggering BBU test on Shenandoah controller(SCGCQ02021398) 
 - Storclio (007.0911.0000.0000) detailed help file doesn't have " locale " option for flashing FW in Dual/Active & Backup mode.(SCGCQ02012025) 
 - hot spare reference in Add Spare command output(SCGCQ01897463) 
 - Shenandoah:Strocli show all output return failure but generates output(SCGCQ01929191) 
 - Junk message "STR_JBOD_OBJ" is displayed in the output of storcli /c0 show JBOD command.(SCGCQ01932770) 
 - Shenandoah_StorCLI: No legend presend for VD Delete Failure(SCGCQ01936811) 
 - Shenandoah_StorCLI:Setting Unmap=OFF gives success for a LD when unmap is not supported and not enabled on that LD(SCGCQ01940291) 
 - Set WrCache= WB ,says success even though VD is in WT.Proper warning message should be given to the user(SCGCQ01940296) 
 - Legend missing for LD BGI resume/pause commands(SCGCQ01940347) 
 - System hangs while creating VD in EFI shell.(SCGCQ01945551) 
 - Shenandoah_StorCLI: Storcli crashes on checking LD preserved cache info(SCGCQ01955069) 
 - CLI is showing the incorrect OS version(SCGCQ01956276) 
 - Unified StorCLI : Add extra space to CBB header(SCGCQ01956678) 
 - PH10 Alpha - StorCLI throws "0 Failed 32782 Failed to get PD Info" when /c0 show executed in EFI(SCGCQ01960322) 
 - JBOD list is not showing in order when using /cx show(SCGCQ01961527) 
 - supported personalities has blank value(SCGCQ01965370) 
 - storcli faults for enclosure show command(SCGCQ01985815) 
 - MR7.10_PA1: Storcli binaries for RHEL/SLES OS is not present for ARM(SCGCQ02006374) 
 - NVMe drive displays incorrect information with IT card(SCGCQ02009852) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02016762) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for snapdump commands.(SCGCQ02018073) 
 - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02018134) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02018135) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02018140) 
 - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02018333) 
 - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02019740) 
 - Instance Validation Failed between " controller-lane-show-schema.json" and "/call/lnall show"(SCGCQ02019746) 
 - Pending Image details are not populated after FW upgrade and downgrade.(SCGCQ02024065) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all "(SCGCQ02032911) 
 - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02034493) 
 - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02035370) 
 - remove the maxconcurrentpd check from storcli and report fw returned failure(SCGCQ02053910) 
 - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02061340) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "show_all"(SCGCQ02062957) 
 - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02064836) 
 - Storcli: "show config" command shown as Un-supported.(SCGCQ02064839) 
 - PH11 Alpha - StorCLI 'show file' command throws segmentation fault for complete flash image in FreeBSD(SCGCQ02065691) 
 - Storcli: No schema files for htbparams commands.(SCGCQ02065698) 
 - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02065734) 
 - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02067575) 
 - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02069817) 
 - Typo in storcli /c0 set linkspeed help(SCGCQ02070951) 
 - Aero (DBU PA2): Storcli: No syntax error displayed for "storcli mronly" command.(SCGCQ02072746) 
 - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02076923) 
 - Empty data is listed when we query for show linkconfig(SCGCQ02076931) 
 - htbparams help output needs update.(SCGCQ02077156) 
 - show/set lane speed shows success when we are in SAS profile(SCGCQ02078437) 
 - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02078513) 
 - Recon command (./storcli /cx set recon) is throwing syntax error.(SCGCQ02081415) 
 - storcli /c0/ex/s23,24 show patrol read doesnt not show error for slot 24 (Invalid Slot)(SCGCQ02082142) 
 - Aero (DBU PA2): Storcli show detailed help does not list "show all " command.(SCGCQ02082303) 
 - Aero (DBU PA2): Storcli: Get rttdump detailed help shows syntax error.(SCGCQ02082460) 
 - Storcli: Incorrect message while executing "storcli64.exe /c0/v0 del discardcache"(SCGCQ02083828) 
 - Failure status for /call/sall and /call/eall/sall command.(SCGCQ02084549) 
 - Storcli: Error in /c0/f0 command output.(SCGCQ02089892) 
 - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02090770) 
 - Storcli doesn't exit with controller status message after doing OFU.(SCGCQ02091548) 
 - Libmod changes for SCGCQ02090770	(SCGCQ02096774) 
 - Aero (DBU PA3): Storcli: FW hits Megamon while executing storcli in EFI shell when EFI Driver is unloaded.(SCGCQ02097647) 
 - StorCLI crashes for 'storcli J command(SCGCQ02117749) 
 - Storcli: VD legend is missing in "/call/vall show expansion" command.(SCGCQ02124508) 
 - Controller Health Status not consisten across applications(SCGCQ02182243) 
 - Perccli does not enable Power Save mode for UG & HS type 1 & type 2.	(SCGCQ02125408) 
 - StorCLI: Delete config failure message need correction(SCGCQ02086726) 
 - StorCLI:VD reference in Delete preserved cahce command output -Branding(SCGCQ02083992) 
 - VD reference in set JBOD command output message(SCGCQ02078507) 
 - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02075242) 
 - STORCLI: Show command output having wrong legend for Slt for oem Hercules(SCGCQ02067616) 
 - Grammatical error in Perccli message(SCGCQ02065513) 
 - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02045967) 
 - VD legend missing in the legend for Foreign config show all output(SCGCQ02016798) 
 - Hercules:Shenandoah:Transformation is coming as Reconstruction , while migrating the Raid 1 to Raid 5 .(SCGCQ01897468) 
 - Mis-spelled words in StorCli's Help(SCGCQ01898853) 
 - Hot spare reference in storcli.exe /cx/ex/sx show all command output(SCGCQ01905019) 
 - Reference to VD in storcli.exe /c1/jbodall delete command output(SCGCQ01905077) 
 - Fixing coverity issues Removing dead code and Out of bound access(SCGCQ01924504) 
 - Shenandoah_StorCLI: HotSpare reference in Add VD Command output(SCGCQ01936887) 
 - storcli /c0 show events output not listing the Event ID's(SCGCQ01940290) 
 - Shenandoah_StorCLI:Hot spare reference in storcli64 /cx show/set restorehotspare command outputs(SCGCQ01940437) 
 - Shenandoah_StorcLI:Drive Group reference in Add dedicated spared drive command in CLI(SCGCQ01955167) 
 - Intel NVMe drive "Model Number" displayed incorrect under Device Attributes(SCGCQ01957949) 
 - Aero: Segmentation Fault in storcli /c0 show all(SCGCQ01996444) 
 - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02006450) 
 - storcli gives error when the lane configuration is set as X8	(SCGCQ02007152) 
 - MR_7.10_Storcli: No schema file for controller unmap commands(SCGCQ02016749) 
 - MR_7.10_Storcli: Instance Validation Failed "controller-restorehotspareoninsertion-schema" and "set restorehotspare"(SCGCQ02016765) 
 - MR_7.10_Storcli: Instance Validation Failed "controller-properties-schema" and "/c0 show"(SCGCQ02016768) 
 - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02016771) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-autoconfig-schema.json" and "show autoconfig" JSON output.(SCGCQ02018227) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02018277) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02018305) 
 - MR_7.10_Storcli: Instance Validation Failed between "system-schema.json" and "./storcli show" and "show all" JSON output.(SCGCQ02018313) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02018327) 
 - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02019729) 
 - Storcli displays drive state as UBad instead of UBad (unsupported)(SCGCQ02031615) 
 - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02040779) 
 - Fixing coverity issues Fixing resource leaks(SCGCQ02043601) 
 - Storcli help file should show the expand size format.(SCGCQ02047109) 
 - Updating the storcli schema mapping document	(SCGCQ02050586) 
 - PH11 Alpha - StorCLI - Parse error observed for command 'StorCLI J' while validating Jason(SCGCQ02053030) 
 - JSON-SCHEMA : IT-Controller Json-schema validation erros in MR_SAS_Unified_StorCLI_7.10(SCGCQ02053914) 
 - Aero: Storcli : Storcli crashed when Firmware upgrade tried on Sea controller(SCGCQ02060276) 
 - Aero (DBU PA2): Storcli: JSON readme file does not have complete VD and PD support list.(SCGCQ02061328) 
 - Instance Validation Failed bw "enclosure-drive-detailed-schema.json" & "/call/eall/sall show all"(SCGCQ02062958) 
 - PH11 Alpha - StorCLI - Compare linkspeed command failed for 6Gbps link(SCGCQ02063932) 
 - Invalid aero controllers are not displayed with apt message in driver less mode(SCGCQ02065581) 
 - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02072448) 
 - Aero (DBU PA2): Storcli: /cx/mx command does not mention about "Auto" settings.(SCGCQ02082208) 
 - Storcli: Force is mentioned as optional in snapdump delete command.	(SCGCQ02083822) 
 - Help of /cx/px compare command needs update and /cx/px reset ? shows syntax error.(SCGCQ02084752) 
 - No proper legends in /fall output.(SCGCQ02100491) 
 - Aero (DBU PA3): Storcli: Incorrect schema mapping for "/cx set autoconfig " command.(SCGCQ02101558) 
 - Storcli: OCR helps needs update.(SCGCQ02113241) 
 - Storcli: No proper description of set and show sesmultipathcfg.(SCGCQ02113358) 
 - StorCLI: File sync issue with rel and dev stream for MR 7.10	(SCGCQ02116806) 
 - Storcli script stops with error "can't fork: Cannot allocate memory"	(SCGCQ02184427) 
 - IT- CLI treats EID and Partner Device ID as two different enclosure during pd info command and fails.(SCGCQ02185442) 
 - "/eall show" will not show enclosure details if it is in multitpath & no drives connected.(SCGCQ02186022) 
 - Legacy messages present with create and rekey of securitykey on controller(SCGCQ01581843) 
 - Shenandoah_StorCLI:VD reference in CLI outout for Firmware update command failure case(SCGCQ02083991) 
 - StorCLI: VD listing for c0 show and vall show is toggled	(SCGCQ02078936) 
 - output information for link configuration is displayed incorrectly(SCGCQ02073046) 
 - Drive Groups is shown instead of arrays in show all command(SCGCQ02048660) 
 - Help is not updated for get snapdump without ID option.(SCGCQ02046991) 
 - StorcliO show oob command fails for Invader based cards(SCGCQ02040783) 
 - Adding debug logs to Mfi files(SCGCQ01891583) 
 - MR7.8_Storcli: Storcli fails to install on ARM server with Missing Maintainer message(SCGCQ01919830) 
 - StorCLI show SAS address for NVMe drives	(SCGCQ01921258) 
 - Unified StorCLI 7.9 : Fixing coverity issues - Dead code,resource leaks,and memory corruption - Part 1(SCGCQ01925503) 
 - Incorrect help option for set autoconfig in StorCli's Help(SCGCQ01932035) 
 - Unmap enabled property is shown in VD detailed properties when controller does not support unmap	(SCGCQ01932177) 
 - Unified StorCLI - Aero : "FullFlashImage" environmental variable component stamp change(SCGCQ01963738) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02018137) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON output.(SCGCQ02018322) 
 - MR_7.10_Storcli: Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show"(SCGCQ02024327) 
 - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #"	(SCGCQ02034064) 
 - Aero IT - PA1 - StorCLI - BIOS verion not displayed with flash file using 'show file' command(SCGCQ02034490) 
 - failure in StorCLI enclosure show status	(SCGCQ02040640) 
 - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02042106) 
 - Incorrect status displayed for pause rebuild command.(SCGCQ02043610) 
 - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044777) 
 - Port information is not displayed for Vses Backplane(SCGCQ02053070) 
 - "c0 delete ?" does not list snapdump command.(SCGCQ02053639) 
 - Incorrect status displayed for resume copyback command.(SCGCQ02062834) 
 - Aero (DBU PA2): Storcli: Instance Validation Failed bw "vd-operations-migrate-schema.json" & "start_migrate"(SCGCQ02062960) 
 - Aero (DBU PA2): Storcli: Result shows blank for "resume patrolread" failure case.(SCGCQ02064795) 
 - Fail to set the linkconfig .	(SCGCQ02070797) 
 - Storcli /c2 set linkconfig conname=c0,c1 configid=14 returns invalid syntax error(SCGCQ02070953) 
 - Aero DBU PA2 : Syntax error is seen in storcli /cx(x|all	(SCGCQ02077085) 
 - Aero (DBU PA2): Storcli: Syntax error for "/c0 download psoc/efibios/cpld/fcode ?" download commands.(SCGCQ02077175) 
 - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02078409) 
 - Incorrect string displayed in show command in FreeBSD OS(SCGCQ02082949) 
 - MR_7.10_Storcli: "storcli show file=filepath" command shows failure status.(SCGCQ02085630) 
 - PCI Linkconfig configid status is failure, even though it was set(SCGCQ02086669) 
 - Storecli_Aero: Using latest storecli show file command "Aero-DVT -HBA 9500-16e" board output version number shows wrong.(SCGCQ02089427) 
 - Libmods changes for defect SCGCQ02062957(SCGCQ02089862) 
 - Help update for "add vd cachevd" command as Normal VD is created with failure status.(SCGCQ02091155) 
 - Preserved cache help file shows a mismatch in command and the convention.(SCGCQ02106218) 
 - Aero DBU PA4 : Storcli doesn't show the convention details properly for storclio /cx/px show command(SCGCQ02113377) 
 - Aero (DBU PA4):Storcli: Syntax error for /c0 show AliLog ?(SCGCQ02113506) 
 - Aero (DBU PA4):Storcli: Typo in /c0 add vd detailed help.(SCGCQ02119091) 
 - Misleading error msg "157 Failed Cannot mix unmap and non-unmap physical drives in same array"(SCGCQ02151484) 
 - Cryptographic erase field is shown "yes" but crypto erase fails.(SCGCQ02175346) 
 - Device Type for non-UBM backplanes are being shown as Enclosure instead of Backplane(SCGCQ02101095) 
 - Multiple status messages are displayed in the output	(SCGCQ02073042) 
 - Controller health status is shown as optimal when megacell cable is disconnected.(SCGCQ02021393) 
 - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump"(SCGCQ01889700) 
 - Shenandoah_StorCLI:32 Binary crashes on giving invalid input to the command storcli.exe /c0/jbod0 show(SCGCQ01905831) 
 - For NVMe drive use the term NVMe instead of PCIe(SCGCQ01923119) 
 - PD show all command displays SSD weargauge details , which is not required.(SCGCQ01927864) 
 - MR_7.10_Storcli: Junk character in error message while creating SED vd with regular HDD drives.(SCGCQ02016701) 
 - MR_7.10_Storcli: Incorrect command syntax mentioned in Schema_mapping_list.xlsx file for "/cx set autoconfig" command.(SCGCQ02018097) 
 - Instance Validation Failed between "vd-operations-bgi-schema.json" and "/call/v1 show bgi " and "show init".(SCGCQ02035551) 
 - Storcli shows incorrect output for delete events command(SCGCQ02045816) 
 - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02048150) 
 - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053923) 
 - StorCLI displays expansion as successful even when there is no free space to expand(SCGCQ02057361) 
 - Instance Validation Failed between "controller-patrolread-schema.json" and "/call resume patrolread"(SCGCQ02062942) 
 - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02063689) 
 - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02064120) 
 - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02064828) 
 - Aero (DBU PA2): Storcli: Inconsistency in "add vd" command syntax.(SCGCQ02082196) 
 - Details are displayed twice in "/cx/bbu start ? "(SCGCQ02100905) 
 - Storcli: set termlog shows [=on|off] mentioned as optional.(SCGCQ02113353) 
 - CLI is missing the JBOD PD size for SysPDs when using the "show jbod" command(SCGCQ02132277) 
 - Percli returns “invalid arguments" when trying to create a VD using some PDs already configured in a VD and some U(SCGCQ02122169) 
 - Topology information missing from Storcli output(SCGCQ02048612) 
 -	(SCGCQ02040597) 
 - Unified StorCLI: StorCLI does not return the return code from SLIT/SLIR3 to explorer/command processors(SCGCQ01925156) 
 - Virtual drive reference in Delete Preserved cache command output(SCGCQ01940333) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940805) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01948579) 
 - Shenandoah : Firmware receives incorrect erase type for sanitize crypto erase option(SCGCQ01958564) 
 - Storcli shows BBU present instead of EnergyPAck in HWcfg for StorCLI /cx show all output.(SCGCQ01985592) 
 - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Sea (3816_Eval) IT Controller(SCGCQ02008219) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for errorcounters commands.(SCGCQ02018078) 
 - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02030652) 
 - There is no error message for smart drive failure command.(SCGCQ02040645) 
 - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02046036) 
 - JSON Schema : Updating the schema list with Virtual drive command set(SCGCQ02057360) 
 - storecli_Aero:In linux error message observed in the show output.(SCGCQ02057699) 
 - Checking in JSON schemas(SCGCQ02061305) 
 - Junck character displayed in Virtual SES phy id, when we query phyerror counter for enclosure.(SCGCQ02094970) 
 - Aero (DBU PA3):Storcli: Help of /cx/px reset does not mention about option hard reset.(SCGCQ02100896) 
 - BBU show detailed help does not list "show learn " command.(SCGCQ02100915) 
 - Storcli: Instance Validation Fails for all /call/e65/sall commands where "e65 is not found".(SCGCQ02101564) 
 - Storcli: Remove Nytro supported options in "/cx [start] flush|flushcache [cachecade | ALL]" help.(SCGCQ02113484) 
 - MR7.10 cli return mesg. typo after ctrl restart then immediately running storcli64 /c0 show.(SCGCQ02113833) 
 - Storcli: /c0 compare help lists /c0/px compare command.(SCGCQ02124246) 
 - Serial number not displayed fully in 7.10 StorCLI 007.1017.0000.0000 for IT Controller(SCGCQ02173789) 
 - Hide BBU details from the command "storcli /c0 show alilog" for HPE(SCGCQ01937259) 
 - Disk group is displayed instead of array on HPE platforms(SCGCQ01965366) 
 - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02016758) 
 - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02024740) 
 - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02034471) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02035437) 
 - Instance Validation Failed for "/call show and /call show all".(SCGCQ02101432) 
 - Instance Validation Failed bw "drive-group-detailed-schema.json" and "/call/dall show all".(SCGCQ02101513) 
 - Autoconfig options are allowed to set with latest storcli(SCGCQ02053643) 
 - Unified StorCLI Phase 10 : Image checksum should not be performed for aero images(SCGCQ01942200) 
 - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02035439) 
 - Fixing coverity issues Fixing resource leaks and explicit NULL dereferencings(SCGCQ02042242) 
 - Unified StorCLI : Fixing resource leaks - Part 1(SCGCQ02042513) 
 - Updating Schema mapping doc and fixing validation errors	(SCGCQ02057434) 
 - Storcli: Instance Validation Fails for vd-bootdrive-schema.json and vd-unmap-schema.json.(SCGCQ02101568) 
 - Aero_storecli:Using latest storecli firmware download fail with noreset option.(SCGCQ02101570) 
 - Aero DBU PA4 : Syntax error is seen for the command - storclio.efi /cx/px set state ?(SCGCQ02113123) 
 - PD info incorrectly shows Number of Blocks for >TB drives(>3TB in my case(SCGCQ02183653) 
 - CLI is returning "success" when attempting to set bios mode to Ignore Errors.(SCGCQ02121017) 
 - On Demand SnapDump does not show proper time stamp.(SCGCQ02084833) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01892288) 
 - Initialize the MFG structure(SCGCQ01901166) 
 - Aero:Storcli: Adaptertype shown as UNKNOWN(X0) for Aero (3916_Eval) IT Controller(SCGCQ02021194) 
 - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02040756) 
 - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02042296) 
 - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047100) 
 - Updating storcli-cmd-list.xlsx for Drives(SCGCQ02056199) 
 - Message with Incorrect controller object is displayed while setting SSD Caching on VD(SCGCQ02057085) 
 - Storcli displays grammatically incorrect message in detailed help file.(SCGCQ02097641) 
 - MR_7.10: Storcli: Property is shown as SCSI Umap instead of SCSI Unmap.(SCGCQ02101572) 
 - Storcli: /c0 show detailed command does not list /cx/px show phyerrorcounters and /cx show vpd.(SCGCQ02113262) 
 - Aero (DBU PA4):Storcli: Incorrect description of "/c0/v0 show migrate" command.(SCGCQ02113511) 
 - Wrong reference of "page=[X]" as part of syntax error message.(SCGCQ02124252) 
 - Storcli: Junk character in PD start locate command description.(SCGCQ02125654)
 - Storcli doesn't exit with controller status message after doing OFU.	(SCGCQ02101069 port of SCGCQ02091548) 
 - perccli /c0 show all lists topology without any DG's present	(SCGCQ02085925 port of SCGCQ01998332) 
 - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) 
 - Libmods: HPE serial number display(SCGCQ02062634 port of SCGCQ01885657) 
 - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) 
 - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) 
 - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) 
 - failure in StorCLI enclosure show status	(SCGCQ02043616 port of SCGCQ02040640) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979616 port of SCGCQ01979599) 
 - Hide "set pdfaileventoptions" command from CLI Help(SCGCQ01892551 port of SCGCQ01880722) 
 - Error message when Maximum number of VDs are reached	(SCGCQ01911777 port of SCGCQ01856544) 
 - Adding CLI command to display/toggle new controller property.(SCGCQ01927583 port of SCGCQ01106982) 
 - System hangs while creating VD in EFI shell.(SCGCQ01945574 port of SCGCQ01945551) 
 - storclio command not working to update FW on SATA disk(SCGCQ01963953 port of SCGCQ01918814) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01963954 port of SCGCQ01937410) 
 - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964173 port of SCGCQ01955389) 
 - Add security-related compilation and linker flags to StorCLI - Linux	(SCGCQ01966163 port of SCGCQ01892560) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations	(SCGCQ01982925 port of SCGCQ01979483) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01985486 port of SCGCQ01893074) 
 - Enable iMR advanced debug dump(SCGCQ02035300 port of SCGCQ01873124) 
 - Drive Size Display Miss Match In Storcli Show Output	(SCGCQ02074659 port of SCGCQ02072353) 
 - HDET:Libmods-Boot device should be presented as /dev/sda in Linux operating system during installation and post installation	(SCGCQ02082198 port of SCGCQ02046182) 
 - HDET: Boot device should be presented as /dev/sda in Linux operating system during installation and post installation(SCGCQ02082199 port of SCGCQ02016712) 
 - BSOD observed when VD/JBOD Creation/Del and snapdump Cycles are initiated.(SCGCQ02085669 port of SCGCQ02045967) 
 - storclif /cx delete colinfo ? shows syntax error	(SCGCQ02124654 port of SCGCQ02124492) 
 - PH12 PA - StorCLI /cx/pall show fails on 9400-8e board(SCGCQ02128167 port of SCGCQ02119004) 
 - Storcli: Force option not mentioned in "/cx/dx add mirror" and "/cx/vx start init" command.(SCGCQ02142248 port of SCGCQ02140878) 
 - Aero (DBU PA5):Storcli: No description of patrolread "OFF" and optional is mentioned as {}.(SCGCQ02145876 port of SCGCQ02140859) 
 - PERCCLI to support creation of VD with WB policy for PERC8 MR(SCGCQ01892550 port of SCGCQ01891650) 
 - MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+	(SCGCQ02139866 port of SCGCQ02066386) 
 - Libmod changes for SCGCQ02090770(SCGCQ02097658 port of SCGCQ02090770) 
 - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) 
 - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) 
 - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) 
 - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) 
 - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) 
 - Drive Size Display Miss Match In Storcli Show Output	(SCGCQ02075280 port of SCGCQ02072353) 
 - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) 
 - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) 
 - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) 
 - Storcli help file doesn't show recon rate command instead it shows migrate rate.	(SCGCQ02047747 port of SCGCQ02046036) 
 - Storcli shows incorrect output for delete events command(SCGCQ02046875 port of SCGCQ02045816) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations	(SCGCQ01979535 port of SCGCQ01979483) 
 - enhance warning message for personality switch indicating interruption could cause controller to be unstable(SCGCQ01892552 port of SCGCQ01892549) 
 - Storcli, should fail the command "get snapdump id=0 file=snapdump.zip norttdump"	(SCGCQ01906745 port of SCGCQ01889700) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) 
 - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01925211 port of SCGCQ01196785) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929137 port of SCGCQ01224857) 
 - For NVMe drive use the term NVMe instead of PCIe	(SCGCQ01963960 port of SCGCQ01923119) 
 - StorCLI show SAS address for NVMe drives	(SCGCQ01963964 port of SCGCQ01921258) 
 - JBOD list is not showing in order when using /cx show(SCGCQ01965193 port of SCGCQ01961527) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965209 port of SCGCQ01949495) 
 - supported personalities has blank value	(SCGCQ01971366 port of SCGCQ01965370) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977028 port of SCGCQ01948579) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979617 port of SCGCQ01979599) 
 - WBSup abbreviation defined twice when running perccli /cX show profile(SCGCQ01995022 port of SCGCQ01993282) 
 - spell mistake in start diag operation failure(SCGCQ01998963 port of SCGCQ01998330) 
 - Proper message to be given on VD creation with wb option while Battery not connected/Failed(SCGCQ02028787 port of SCGCQ01972504) 
 - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02028810 port of SCGCQ02008676) 
 - Enable iMR advanced debug dump(SCGCQ02035289 port of SCGCQ02030908) 
 - On Demand SnapDump does not show proper time stamp.(SCGCQ02085609 port of SCGCQ02084833) 
 - Flashing of Completeflash fails on Sea IT controller(SCGCQ02139848 port of SCGCQ02139780) 
 - Storcli: "Ctrl" legend not mentioned.(SCGCQ02150640 port of SCGCQ02146822) 
 - storcli -help missing the verbose option	(SCGCQ02160908 port of SCGCQ02158600) 
 - MR7.11_Storcli: Incorrect error description while creating r1 with single drive(SCGCQ02168183 port of SCGCQ02165933) 
 - Phase 12 - Oct Huawei DET - Incorrect Phy Details Displayed for Ventura IT Controller(SCGCQ02179296 port of SCGCQ02174296) 
 - Incorrect Help Menu For "show phyerrorcounters"(SCGCQ02180519 port of SCGCQ02180495) 
 - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) 
 - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) 
 - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) 
 - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) 
 - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) 
 - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) 
 - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) 
 - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) 
 - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.	(SCGCQ02047079 port of SCGCQ02024740) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) 
 - storcli faults for enclosure show command(SCGCQ01986423 port of SCGCQ01985815) 
 - storclio command not working to update FW on SATA disk(SCGCQ01922919 port of SCGCQ01918814) 
 - Restricting PD FW download enable command to FW for SATA drives(SCGCQ01964153 port of SCGCQ01955389) 
 - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01965185 port of SCGCQ01413253) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01965210 port of SCGCQ01949503) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01966261 port of SCGCQ01893074) 
 - Add security-related compilation and linker flags to StorCLI - Linux	(SCGCQ01985558 port of SCGCQ01892560) 
 - Snapdump unsupported commands for HPE needs to be disabled(SCGCQ01996375 port of SCGCQ01985589) 
 - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02009848 port of SCGCQ01992461) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02011417 port of SCGCQ01761309) 
 - StorcliO show oob command fails for Invader based cards(SCGCQ02043788 port of SCGCQ02040783) 
 - Storclif doesn't show details for VF/PF in help file for vfmap command .(SCGCQ02124488 port of SCGCQ02123789) 
 - Storcli: "completeflash" is listed in Windows help file.(SCGCQ02145743 port of SCGCQ02141931) 
 - Storcli: /c0 set ? lists bbu,mx,px and lnx commands.	(SCGCQ02145756 port of SCGCQ02136689) 
 - Configuring multiple lane speed is working only for fisrt ID, Rest were ignored(SCGCQ02145764 port of SCGCQ02136333) 
 - Help note 'page=[x]' needs update(SCGCQ02149062 port of SCGCQ02146823) 
 - Instance Validation Failed for "/call/eall show status extended" and enclosure-status-extended-schema.json(SCGCQ02153948 port of SCGCQ02150924) 
 - Instance Validation Failed for /call/show_all.json and controller-detailed-properties-schema.json(SCGCQ02154721 port of SCGCQ02135526) 
 - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) 
 - Aero (DBU PA2(SCGCQ02086670 port of SCGCQ02082460) 
 - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) 
 - show/set lane speed shows success when we are in SAS profile(SCGCQ02079507 port of SCGCQ02078437) 
 - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) 
 - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) 
 - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) 
 - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all	(SCGCQ02047235 port of SCGCQ02040756) 
 - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) 
 - Request to Disable DSW3(SCGCQ01903331 port of SCGCQ01896311) 
 - PERCCLI Support for EKMS(SCGCQ01904188 port of SCGCQ01902150) 
 - StorCLI crashes, while trying to enable security on any DG ,incase, when no DG exists(SCGCQ01904340 port of SCGCQ01413253) 
 - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921529 port of SCGCQ01220901) 
 - Hide "set termlog" help contents from perccli(SCGCQ01935143 port of SCGCQ01923643) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01940869 port of SCGCQ01937410) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01945534 port of SCGCQ01940805) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01965393 port of SCGCQ01935697) 
 - Storcli shows wrong PD list sequence.(SCGCQ01971632 port of SCGCQ01967488) 
 - LD size not shown in GiB format in foreign import preview(SCGCQ01996370 port of SCGCQ01978978) 
 - Unable to switch to eHBA mode using a H745P Adapter(SCGCQ01998964 port of SCGCQ01990060) 
 - perccli show profile lists personality as JBOD instead of eHBA(SCGCQ01998966 port of SCGCQ01998328) 
 - Json Schema for the command "storcli /cx/ex show phyerrorcounters" needs to be updated(SCGCQ02101377 port of SCGCQ02101372) 
 - In ARM server UEFI shell, storcli.efi hangs forever when storcliconf.ini is present(SCGCQ02116733 port of SCGCQ02115036) 
 - complete Lane WWID is not displayed(SCGCQ02145739 port of SCGCQ02145716) 
 - No "Rbld" legend during rebuild.	(SCGCQ02150634 port of SCGCQ02146819) 
 - Error message mismatch is seen for rttdump command on iMR Ventura controller.(SCGCQ02160907 port of SCGCQ02156483) 
 - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) 
 - Multiple status messages are displayed in the output	(SCGCQ02086536 port of SCGCQ02073042) 
 - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) 
 - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324)
 - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) 
 - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) 
 - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) 
 - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) 
 - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) 
 - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #"	(SCGCQ02034200 port of SCGCQ02034064) 
 - Storcli shows wrong PD list sequence.(SCGCQ01977461 port of SCGCQ01967488) 
 - Migrate Failure case is not Branding compliant(SCGCQ02000716 port of SCGCQ01988402) 
 - StorCLI PH12: Retrieving topology details causes application crash in some scenario(SCGCQ02106192 port of SCGCQ02103217) 
 - Support FMP Images in UEFI Version of PERCCli(SCGCQ02116464 port of SCGCQ02078649) 
 - MR 7.11: Storcli.efi: On ARM server, incomplete configuration data received error is observed for any storcli.efi command(SCGCQ02116497 port of SCGCQ02114898) 
 - PH12 PA - StorCLI - 9310-8i IR FW download fails	(SCGCQ02121848 port of SCGCQ02121783) 
 - LibMod changes : MR: 64 Bit Utilities/Application to Support VMWARE ESXi 6.7+(SCGCQ02139867 port of SCGCQ02085102) 
 - MR7.11_Storcli: On drive rebuild, there is a mismatch between the pd rebuild state and respective legend	(SCGCQ02168256 port of SCGCQ02165944) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/px commands.(SCGCQ02079604 port of SCGCQ02018137) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"(SCGCQ02079597 port of SCGCQ02035437) 
 - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) 
 - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) 
 - Incorrect status displayed for resume copyback command.	(SCGCQ02075291 port of SCGCQ02062834) 
 - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) 
 - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01929892 port of SCGCQ01106988) 
 - Added new commands from StorCLI(SCGCQ01935296 port of SCGCQ01134166) 
 - For NVMe drive use the term NVMe instead of PCIe	(SCGCQ01964024 port of SCGCQ01923119) 
 - securesed autoconfig param should not be present for perccli help(SCGCQ01986879 port of SCGCQ01986831) 
 - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032582 port of SCGCQ02029410) 
 - Drives connected to active backplanes not showing the phy info in connector name	(SCGCQ02112425 port of SCGCQ02112424) 
 - Background operations keep on progressing after hitting /c0 shutdown from storcli(SCGCQ02150630 port of SCGCQ02132024) 
 - Instance Validation Failed for "/call/eall show status" and enclosure-status-schema.json(SCGCQ02153950 port of SCGCQ02150921) 
 - Instance Validation Failed for "/call/cv show all" and cache-vault-detailed-schema.json(SCGCQ02154755 port of SCGCQ02150651) 
 - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) 
 - Port information is not displayed for Vses Backplane	(SCGCQ02085875 port of SCGCQ02053070) 
 - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.	(SCGCQ02079601 port of SCGCQ01992461) 
 - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) 
 - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) 
 - Storcli: HPE serial number programming and display(SCGCQ02062635 port of SCGCQ01882984) 
 - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) 
 - FW flash fails to load the latest image after upgrade downgrade with resetnow option	(SCGCQ02046879 port of SCGCQ02035152) 
 - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) 
 - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893381 port of SCGCQ01892288) 
 - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01930028 port of SCGCQ01141462) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01936895 port of SCGCQ01935697) 
 - Terminology change from " Data protection" to " Data integrity".(SCGCQ01940807 port of SCGCQ01827339) 
 - Libmods: Terminology change from " Data protection" to " Data integrity".(SCGCQ01943370 port of SCGCQ01827732) 
 - Incorrect colinfo output of Bad block count(SCGCQ01977457 port of SCGCQ01977443) 
 - StorCLI hangs when viewing controller in FreeBSD (MR7.8 is okay(SCGCQ01984543 port of SCGCQ01978824) 
 - Unified StorCLI : Help command of "Get flash" is not shown in generic help syntax(SCGCQ01985472 port of SCGCQ01985463) 
 - StorCLI show output shows Legends as BBU instead of EnergyPack.(SCGCQ01992007 port of SCGCQ01985587) 
 - Aero A0 UTP: StorCLI snapdump command needs to clarify new "On Demand" snapdump option(SCGCQ01995066 port of SCGCQ01993722) 
 - Shenandoah:StorCLI:Right click properties for released binary shown blank.(SCGCQ02000843 port of SCGCQ01988329) 
 - Smart Carrier Enclosure port info shown as "Multuipath"(SCGCQ02008273 port of SCGCQ01992087) 
 - MR 7.11: Storcli: Instance Validation Failed for "/call show all" and system-schema.json	(SCGCQ02116771 port of SCGCQ02112192) 
 - "Storcli /c# set jbod=on" shows success but does nothing	(SCGCQ02119067 port of SCGCQ02117219) 
 - Phyreset Fails on IT controllers	(SCGCQ02169305 port of SCGCQ02169242) 
 - Storcli stop erase needs an help file update	(SCGCQ02169308 port of SCGCQ02168895) 
 - Updating phy link reset logic for IT cards with respect to storelib changes(SCGCQ02185911 port of SCGCQ02184862) 
 - Storcli connector display not matching with Aero board 9560-16i.	(SCGCQ02085681 port of SCGCQ02072448) 
 - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) 
 - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) 
 - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) 
 - remove the maxconcurrentpd check from storcli and report fw returned failure	(SCGCQ02053931 port of SCGCQ02053910) 
 - PERCCLI Support for EKMS	(SCGCQ01904189 port of SCGCQ01903448) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911832 port of SCGCQ01886637) 
 - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915313 port of SCGCQ01222855) 
 - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915315 port of SCGCQ01227144) 
 - perccli /c0 show all lists topology without any DG's present(SCGCQ01998965 port of SCGCQ01998332) 
 - PH12 PA - StorCLI version not getting printed for show file command	(SCGCQ02116759 port of SCGCQ02105185) 
 - Convention comes in same line while performing help for /c0/e0/s0 download.(SCGCQ02176697 port of SCGCQ02176681) 
 - With IT controller for set or reset with invalid phy is not showing error(SCGCQ02183510 port of SCGCQ02181823) 
	
EnhancementRequests:
 - Incorporating VMware constraints for PERCCLI VIB signing	(SCGCQ02190441) 
 - Migrating VMware 64 bit toolchain to 6.8.7-13394445(SCGCQ02190429) 
 - Create an event for DDF config clear failed event.(SCGCQ02173513) 
 -	(SCGCQ02162699) 
 - Snap Dump ClearAll Method logging event(SCGCQ02157359) 
 - API changes for a better presentation of Atlas to tools(SCGCQ02149380) 
 - Add disableOffloadNum field in MR_SNAPDUMP_PROPERTIES struct(SCGCQ02125252) 
 - Better error message for certain unmap operations(SCGCQ02111563) 
 - Add MFI STAT and MR Event for Secure Boot indicating fw dl was not allowed due to an existing pending key change(SCGCQ02103973) 
 - MR Windows IOCTL Error codes to Application added to MR API(SCGCQ02103183) 
 - API changes for linkconfig interface	(SCGCQ02053671) 
 - API changes for NVMe speed and width changes	(SCGCQ02053667) 
 - Reword event log messages as it creates unnecessary panic.(SCGCQ02013675) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949495) 
 - Unified StorCLI : Adding component level download functionality to StorCLI(SCGCQ01940030) 
 - show complete Serial Number and Model Name for NVMe drive(SCGCQ01927541) 
 - snapdump support for host initiated snapdump	(SCGCQ01901158) 
 - Changes for disable least latency mode(SCGCQ01891451) 
 - Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01929656) 
 - MR_SAS_Unified_Libmods_7.10 Inspur request to add to show smart info of sas drive for "StorCLI /cx/ex/sx show smart" command(SCGCQ01979597) 
 - Post firmware trace buffer at the time of driver load(SCGCQ01992779) 
 - Adding the spare details in the same volume creation(CONFIG_ADD DCMD(SCGCQ02008407) 
 - PSoC implementation in StorCLI by parsing PSoC image(SCGCQ02072160) 
 - Request to display the help for "show" and "set" for JBOD in PercCLI	(SCGCQ02160291) 
 - Adding NVACHE messages indicate when SLC format has started and completed.(SCGCQ02137048) 
 - MR API: Add support bits for currentSpeed and clkMode(SCGCQ02132334) 
 - Enable iMR advanced debug dump(SCGCQ02030908) 
 - Unified StorCLI : ARM Windows support to StorCLI(SCGCQ01962294) 
 - Disabling RAID00 support	(SCGCQ01960420) 
 - HPE Shenandoah: Branding tool(SCGCQ01960295) 
 - Added Windows compiler security flags (SDL and control flow guard(SCGCQ01949503) 
 - Unified StorCLI : Allow SBR/SPD read and write using new CBB+SBR concatenated image(SCGCQ01927551) 
 - show complete Serial Number and Model Name for NVMe drive connected to IT controller(SCGCQ01927538) 
 - show complete Serial Number and Model Name for NVMe drive(SCGCQ01919655) 
 - Unified CLI - Command processor changes for handling invalid/tampered device id's for sea IT controllers(SCGCQ01891513) 
 - Add support to display PSOC version for Ventura IT controllers(SCGCQ02067300) 
 - set copyback command changes for cli(SCGCQ02148092) 
 - Unified StorCLI : ARM64 Windows support to StorCLI - LibMod changes(SCGCQ01963208) 
 - Shenandoah: Adding support bit check for delete snap dump(SCGCQ01944500) 
 - Enable iMR advanced debug dump(SCGCQ01873124) 
 - Unified StorCLI : PSoC read and write via Device read and write DCMD's in MR Operational case(SCGCQ01949521) 
 - Changes for disable least latency mode(SCGCQ01891442) 
 - Adding the spare details in the same volume creation (CONFIG_ADD DCMD(SCGCQ02008403) 
 - Unified StorCLI : Allow erase functionality on operational MR using CBB concatenated image(SCGCQ01927595) 
 - Unified CLI : Handling invalid/tampered controllers for sea controllers(SCGCQ01891484) 
 - Requesting StorCLIF to read MR FW from flash device and write it to a file. Similar to what IT FW support.(SCGCQ01631948) 
 - Add ability to field upgrade PSOC on HBA boards(SCGCQ01583214) 
 - DUal Image SUpport(SCGCQ01960287) 
 - Libmods: Porting HPE Shenandoah from Aero to 7.9	(SCGCQ01917263) 
 - Porting HPE Shenandoah from Aero to 7.9(SCGCQ01917172) 
 - Adding HPE specific help for storcli	(SCGCQ01935699) 


007.0816.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

defects:
  - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01824574 port of SCGCQ01824569) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01827604 port of SCGCQ01681538) 
 - Updating makefile and EFI's INF changes for ARM StorCLIO(SCGCQ01870684 port of SCGCQ01563125) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) 
 - failure in StorCLI enclosure show status	(SCGCQ02043616 port of SCGCQ02040640) 
 - MR_7.10_Storcli: Instance Validation Failed between "virtual-drive-detailed-schema.json" and "/call/vall show all "(SCGCQ02050471 port of SCGCQ02018333) 
 - MR_7.10_Storcli: unmap attribute is not mentioned in "/c0 add vd" command syntax in Schema_mapping_list.xlsx file.(SCGCQ02050535 port of SCGCQ02016758) 
 - Aero DBU PA1:Storcli: Instance Validation Failed "controller-properties-schema" and "/call show" command.(SCGCQ02061387 port of SCGCQ02035439) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for drive jbod commands.(SCGCQ02079592 port of SCGCQ02018135) 
 - MR_7.10_Storcli: bbu-show-modes-schema.json file is not in JSON format.(SCGCQ02079618 port of SCGCQ02019740) 
 - perccli /c0 show all lists topology without any DG's present(SCGCQ02085925 port of SCGCQ01998332) 
 - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853370 port of SCGCQ01775616) 
 - (SCGCQ01775602 port of SCGCQ01814011)
 - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911831 port of SCGCQ01886637) 
 - Storcli shows incorrect output for delete events command	(SCGCQ02046875 port of SCGCQ02045816) 
 - Storcli help file doesn't show recon rate command instead it shows migrate rate.(SCGCQ02047747 port of SCGCQ02046036) 
 - Storcli reported "Boot Volume Supported = NO" eventhough ctrl boot with OS on vd.(SCGCQ02047809 port of SCGCQ02030652) 
 - PH11 Alpha - StorCLI - 'show file' command displays incorrect message after reading uploaded bios file(SCGCQ02064703 port of SCGCQ02063689) 
 - Typo in storcli /c0 set linkspeed help(SCGCQ02074664 port of SCGCQ02070951) 
 - Drive Size Display Miss Match In Storcli Show Output(SCGCQ02075280 port of SCGCQ02072353) 
 - BreakMirror RAID Support coming as Yes, even when Breakmirror is not supported(SCGCQ02075281 port of SCGCQ02048150) 
 - Storcli: "resume migrate" command does not show syntax error.(SCGCQ02075292 port of SCGCQ02061340) 
 - Storcli displays drive state as UBad instead of UBad (unsupported(SCGCQ02079521 port of SCGCQ02031615) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON output.(SCGCQ02079591 port of SCGCQ02018305) 
 - CLI returns wrong error code upon failure(SCGCQ02085528 port of SCGCQ02084966) 
 - Wide port info is not displayed under connector name for Backplane attached drives.(SCGCQ02085666 port of SCGCQ02076923) 
 - Libmod changes for SCGCQ02090770	(SCGCQ02097658 port of SCGCQ02096774) 
 - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01850374 port of SCGCQ01837932) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ02009900 port of SCGCQ01761309) 
 - Storcli pop-up a message "controller not found" during chip reset , rather than controller busy.(SCGCQ02047079 port of SCGCQ02024740) 
 - unmap attribute is not mentioned in help file command "add vd each r0".(SCGCQ02047095 port of SCGCQ02042106) 
 - Instance Validation Failed between "drive-group-hidden-schema" and "/c1/dall set hidden" & "set security"(SCGCQ02047136 port of SCGCQ02040779) 
 - Unified StorCLI : Individual SL_INIT_LIB calls are made for every SL command invocation(SCGCQ02047893 port of SCGCQ02047100) 
 - Spell mistake on support ondemand snapdump property of show all output(SCGCQ02053926 port of SCGCQ02053923) 
 - iMR Changing profileid's using cli results in Status=Success Description=None(SCGCQ02056156 port of SCGCQ02008676) 
 - Show Snapdump help command lists delete snapdump details as well.(SCGCQ02075287 port of SCGCQ02064836) 
 - Need a space between atleast with StorCLI error message "Unmap is not supported atleast on one device"(SCGCQ02075290 port of SCGCQ02064120) 
 - Recon command (./storcli /cx set recon(SCGCQ02086570 port of SCGCQ02081415) 
 - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) 
 - PH11 PA - StorCLI - Segmentation fault seen when 'compare linkspeed' executed on Fury C0 board(SCGCQ02044794 port of SCGCQ02044777) 
 - Instance Validation Failed between "drive-group-schema.json" and "/call/dall show " and /call/dall show all(SCGCQ02047235 port of SCGCQ02040756) 
 - Instance Validation Failed between "vd-unmap-schema.json" and "/call/vall show unmap"(SCGCQ02047243 port of SCGCQ02035370) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for "/cx get vpd" commands.(SCGCQ02058567 port of SCGCQ02018140) 
 - Schema file updates for controller show all output change for defect SCGCQ02048150(SCGCQ02075282 port of SCGCQ02069817) 
 - Storcli: "show config" command shown as Un-supported.(SCGCQ02075286 port of SCGCQ02064839) 
 - show/set lane speed shows success when we are in SAS profile	(SCGCQ02079507 port of SCGCQ02078437) 
 - storclif.exe /c0/ex/sx show poh should show proper message during command execution.(SCGCQ02086632 port of SCGCQ02075242) 
 - Aero (DBU PA2)(SCGCQ02086670 port of SCGCQ02082460) 
 - StorCLI listing PD Slot Status as "Incorrect Status Value" for configured PD's(SCGCQ02097676 port of SCGCQ02090770) 
 - Error message when Maximum number of VDs are reached	(SCGCQ01857450 port of SCGCQ01856544) 
 - Aero UTP: storclif /call show commands output contains "Count 4 exceeded for token id #"	(SCGCQ02034200 port of SCGCQ02034064) 
 - PH11 PA Storcli: Incorrect error message shown while programming invalid sasaddress(SCGCQ02043612 port of SCGCQ02042296) 
 - Incorrect status displayed for pause rebuild command.(SCGCQ02046878 port of SCGCQ02043610) 
 - "Invalid RAID level" error message while creating R10 VD.(SCGCQ02047806 port of SCGCQ02034471) 
 - MR_7.10_Storcli: Add VD command output is not in JSON format.(SCGCQ02050489 port of SCGCQ02034493) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set personality" JSON output.(SCGCQ02050491 port of SCGCQ02016762) 
 - "Run time to empty" field showing as "Battery is not being charged" when the battery is being charged.(SCGCQ02079535 port of SCGCQ02045324) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" JSON output.(SCGCQ02079590 port of SCGCQ02018277) 
 - MR_7.10_Storcli: No schema file for controller sesmultipathcfg commands.(SCGCQ02079595 port of SCGCQ02018134) 
 - Multiple status messages are displayed in the output	(SCGCQ02086536 port of SCGCQ02073042) 
 - Storcli throws different error messages for show status command in Ventura and Aero(SCGCQ02086689 port of SCGCQ02078409) 
 - Improve Debuggablity for MegaRAID Windows Driver by Adding RT Trace - new modifications(SCGCQ01825986 port of SCGCQ01824570) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01832791 port of SCGCQ01816927) 
 - Add interface in storecli that could get relearn complete status	(SCGCQ01850373 port of SCGCQ01848387) 
 - MR_7.10_Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/ eall/sall show all"(SCGCQ02050481 port of SCGCQ02018327) 
 - "Delete snapdump" command shows same description "Snapdump clear" for success and failure case.(SCGCQ02075284 port of SCGCQ02065734) 
 - Incorrect status displayed for resume copyback command.(SCGCQ02075291 port of SCGCQ02062834) 
 - Libmods: show.set lane speed shows success with wrong data when we are in SAS profile(SCGCQ02079506 port of SCGCQ02078513) 
 - Empty data is listed when we query for show linkconfig(SCGCQ02079511 port of SCGCQ02076931) 
 - MR_7.10_Storcli: Instance Validation Failed between "controller-patrolread-schema.json" and "/call pause patrolread"	(SCGCQ02079597 port of SCGCQ02035437) 
 - MR_7.10_Storcli: No "schema and command" mapping details in Schema_mapping_list.xlsx file for /cx/ px commands.(SCGCQ02079604 port of SCGCQ02018137) 
 - Aero - LibMod changes for ER SCGCQ01813156 : Addition of Aero and Sea device id's and checkwords	(SCGCQ01853418 port of SCGCQ01813626) 
 - Storcli throws an 'Incomplete foreign configuration' error when there is no enclosure connected(SCGCQ02007109 port of SCGCQ02006450) 
 - Extend major downgrade support in storCLI for SAS3 IT product(SCGCQ02032581 port of SCGCQ02029410) 
 - FW flash fails to load the latest image after upgrade downgrade with resetnow option	(SCGCQ02046879 port of SCGCQ02035152) 
 - MR_7.10_Storcli: Instance Validation Failed between "cache-vault-detailed-schema.json" and "/call/cv show all "(SCGCQ02050460 port of SCGCQ02019729) 
 - Storcli:"resource already in use" error message displayed when trying to create VD with one UG and one UBUnsp.(SCGCQ02075289 port of SCGCQ02064828) 
 - spell mistake in start diag operation failure(SCGCQ02079529 port of SCGCQ01998330) 
 - MR_7.9: Storcli reported unknown OS for Windows 10 RS5 LTSC.(SCGCQ02079601 port of SCGCQ01992461) 
 - Port information is not displayed for Vses Backplane	(SCGCQ02085875 port of SCGCQ02053070) 
 - Storcli: Force is mentioned as optional in snapdump delete command.(SCGCQ02086544 port of SCGCQ02083822) 
 - Add get VPD command support to StorCLI in OS environment	(SCGCQ01855067 port of SCGCQ01852603) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) 
 - CSET: Checking in Libmod changes for defect SCGCQ02030652 - (SCGCQ02045948(SCGCQ02047884 port of ) 
 - remove the maxconcurrentpd check from storcli and report fw returned failure	(SCGCQ02053931 port of SCGCQ02053910) 
 - Incorrect error message displayed while creating R10 VD when no free space available.(SCGCQ02075283 port of SCGCQ02067575) 
 - MR_7.10_Storcli: No schema file for controller unmap commands.(SCGCQ02079593 port of SCGCQ02016749) 
 - MR_7.10_Storcli: controller-detailed-properties-schema.json or "/call show all " output not in JSON format(SCGCQ02079610 port of SCGCQ02016771) 
 - Storcli connector display not matching with Aero board 9560-16i.(SCGCQ02085681 port of SCGCQ02072448)

EnhancementRequest:
- Updating ncurses library from 6.0 to 6.1(SCGCQ01836749) 
 - Command processor changes for Secure boot properties feature - SCGCQ01855473	(SCGCQ01855503) 
 - Adding secure boot properties to unified StorCLI	(SCGCQ01855473) 
 - Adding new MFI STAT - MFI_STAT_SECURE_BOOT_KEY_SLOTS_FULL 007.0711.0000.0000 for Lenovo(SCGCQ01865190) 

007.0713.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01529009) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01537017) 
 - storcli /c0 set sasaddhi =xxxx sasaddlow =xxxx displays incomplete sasaddress(SCGCQ01540807) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01556595) 
 - controller show all command is not listing the Battery information(SCGCQ01561689) 
 - Commands "/call/<x>all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01561703) 
 - Instance Validation Failed between "vd-operations-migrate-schema.json" and "start migrate" JSON output.(SCGCQ01571207) 
 - Storcli: drive-group-security-schema.json is not present in the JSON Schema folder(SCGCQ01571280) 
 - Storcli: Instance Validation Failed between "drive_group_mirror_schema.json" and "/call/dall add mirror src=0" JSON output.(SCGCQ01571298) 
 - Instance Validation Failed "foreign-configuration-detailed-schema.json" and "/call/fall import preview" JSON output(SCGCQ01571393) 
 - "drive-power-on-schema.json" is named as "drive-get-power-on-schema.json" in "Schema_mapping_list" file.(SCGCQ01573229) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01589618) 
 - BBU-show-schema is not present in the schema mapping list, the list needs to be sorted to remove duplicate commands.(SCGCQ01599473) 
 - Coverity defect fixes for Uninitialized Variables, resource leaks(SCGCQ01600257) 
 - Spell mistake in error message for hwdev command(SCGCQ01614972) 
 - Coverity defect fix for itctflash file(SCGCQ01616369) 
 - Fixing coverity issues - Resource leaks - Part 5(SCGCQ01627961) 
 - Fixing coverity issues - Non array deletes - Part 6(SCGCQ01629478) 
 - CLI help does not reflect the new command to create an ePD(SCGCQ01639583) 
 - ModeE drive fw download not working when drive image is more than 32K(SCGCQ01681086) 
 - Space need in the output for Deprecated command in storclif64.exe when legacy Cli command is used(SCGCQ01687653) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033) 
 - storclif /c0 start diag type=0, gives syntax error(SCGCQ01714663) 
 - Correcting the grammatical errors in firmware's MFI Stat messages(SCGCQ01717315) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718269) 
 - MR 7.7 - Storcli throws an incorrect error msg while importing foreign config from Raid to JBOD mode.(SCGCQ01718981) 
 - Unmap property is not displayed for a drive in drive show all command output(SCGCQ01720959) 
 - Unified StorCLI 7.7 : StorCLI should allow noreset option when current NVDATA is lesser than the new NVDATA for SAS3.5 IT(SCGCQ01727159) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731280) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749849) 
 - Help content for jbodx show unmap is not present(SCGCQ01790130) 
 - One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01816927) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01837612) 
 - MR API - Incorrect value used for MR_DCMD_CTRL_SNAPDUMP_ONDEMAND(SCGCQ01882581) 
 - storclio command not working to update FW on SATA disk(SCGCQ01918814) 
 - Storcli- Delay seen in /c0 /vall show all o/p(SCGCQ01935697) 
 - Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A"(SCGCQ01292964) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01520816) 
 - Storcli: vd-delete-schema.json is not present in the JSON Schema folder(SCGCQ01571254) 
 - Instance Validation Failed between "controller-properties-schema.json" and "/call show" JSON output.(SCGCQ01573076) 
 - Unified LibMods : Fixing coverity issues - Resource leaks and Uninitialized variables - Part 2(SCGCQ01600381) 
 - Unified LibMods : Coverity fixes for uninitialized variables in File functions - Part 4(SCGCQ01606830) 
 - Checking in VBAS compliation changes(SCGCQ01630324) 
 - PERCCLI ePD personality behavior command is still an available option and has not been removed(SCGCQ01639798) 
 - Instance Validation Failed "system-schema.json" and "storcli64.exe show all" JSON output.(SCGCQ01640825) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713240) 
 - Space need in the output for secure erase(SCGCQ01713604) 
 - PA2-MR7.7-StorCLI: "storcli /c0/v239 start migrate type=raid0 option=add drives=66:18" gives syntax error(SCGCQ01713681) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01714356) 
 - StorCLI 7.702 help for SnapDump is not clear(SCGCQ01715025) 
 - IT Fw Download command StorCLI /c0/eall/sall hang(SCGCQ01723226) 
 - Unified StorCLI Phase 8 : No help section for ForceHCB option(SCGCQ01731292) 
 - Unified CLI 7.7 : Fixing coverity issues - Resource leaks,Unused variables,and non-array deletes - Part 1(SCGCQ01732959) 
 - Unified StorCLI Phase 8 : Firmware downgrade should be supported only by StorCLIO for SAS3 IT controllers(SCGCQ01734559) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01735493) 
 - Storcli vib update fails across releases.(SCGCQ01761795) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01775602) 
 - StorCLI enable/disable unmap VDs return status as failed instead of successful(SCGCQ01803306) 
 - Removing the set/show of unmap on JBOD.(SCGCQ01817855) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539360) 
 - Storcli: Instance Validation Failed between "drive-group-detailed-schema.json" and "/call/dall show all" JSON output.(SCGCQ01571287) 
 - Instance Validation Failed between "foreign-configuration-schema.json" and "/call/fall show" JSON output.(SCGCQ01571391) 
 - Instance Validation Failed between "controller-detailed-properties-schema.json" and "/call show all" JSON output.(SCGCQ01573096) 
 - "drive-security-key-schema.json" is named as "drive-securitykey-schema.json" in "Schema_mapping_list" file.(SCGCQ01573226) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01595640) 
 - Json schema for enclosure phyerrorcounters has not been added, output format needs modification.(SCGCQ01595673) 
 - Unified StorCLI 7.7 : SAS Phyloopback test reports false positive results(SCGCQ01624063) 
 - Update help contents for jbod delete(SCGCQ01624605) 
 - Drive download commands help syntax to be updated for IT.(SCGCQ01681089) 
 - Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670) 
 - Missing punctuation in Perccli delete config message(SCGCQ01698226) 
 - Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749795) 
 - Storcli is not showing foreign configs if user has SED drive which is in foreign(SCGCQ01937410) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01561704) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01571256) 
 - Instance Validation Failed between "system-schema.json" and "show all" JSON output.(SCGCQ01571961) 
 - Unified StorCLI 7.7 : Coverity issues - Resource leaks,Uninitialized variables,and dead code - Part 1(SCGCQ01600195) 
 - Drive Fw download Coverity fixes(SCGCQ01615074) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01676983) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01571154) 
 - Coverity defect fixes for Memory Leak, Uninitialized pointers(SCGCQ01605182) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01732990) 
 - MR7.7 LSA 4.180.0 enclosure type is not matched with storcli(SCGCQ01747333) 
 - Coverity libmods issues - Resource leaks and Wrong sizes(SCGCQ01600208) 
 - Unified StorCLI 7.7 : MegaCLI commands report command status code in UEFI environment(SCGCQ01624506) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01713676) 
 - Unmap support mfc bit and fde type mixing fields needs to be updated when extracting factory settings and also while modifying factory settings(SCGCQ01640217) 	
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01731279) 
 - Updating the Diag results as per new API changes(SCGCQ01537255) 
 - Resource leaks,Uninitialized variables(SCGCQ01600311) 
 - Unified CLI : Coverity fixes for Uninitialized variables,resource leaks,and dead code handling - Part 3(SCGCQ01606785) 
 - Unified StorCLI 7.7 - Fixing coverity issues Resource leaks,Non-array deletes - Part 2(SCGCQ01757433) 
 - Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752) 
 - Removal of ncurses references for linux makefile(SCGCQ01955544) 
  - Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496) 
 - Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01529059 port of SCGCQ01458174) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537219 port of SCGCQ01534552) 
 - Handle memory leaks in getSortedPdList(SCGCQ01571890 port of SCGCQ01283497) 
 - Disk sorting based on connector name, slot and position(SCGCQ01571926 port of SCGCQ01307257) 
 - Collecting snapdump through StorCli(SCGCQ01594186 port of SCGCQ01581899) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01595361 port of SCGCQ01588245) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01599545 port of SCGCQ01514483) 
 - Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01600142 port of SCGCQ01589445) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01619201 port of SCGCQ01606780) 
 - Storcli should not create a snapdump image if there is no valid image(SCGCQ01624677 port of SCGCQ01623883) 
 - Removing readonly properties from for snapdump in storcli.(SCGCQ01669986 port of SCGCQ01669570) 
 - Different RetCode for N/A Drives - Parallel Drive Update(SCGCQ01682236 port of SCGCQ01681478) 
 - Storcli: VD creation fails from storcli in presence of 0KB bad drive .(SCGCQ01713567 port of SCGCQ01713240) 
 - Flashing PD's with parallel option wrong status is given by Storcli(SCGCQ01714667 port of SCGCQ01713734) 
 - Missing punctuation in Perccli delete config message(SCGCQ01714668 port of SCGCQ01698226) 
 - When a bad PD is flashed it fails as expected but error code is wrong(SCGCQ01714670 port of SCGCQ01713728) 
 - Parallel drive fw update on 1st drive fails, while drive fW update on another drive is in progress(SCGCQ01714671 port of SCGCQ01676426) 
 - Enclosure show status command gives success but nothing is shown(SCGCQ01731381 port of SCGCQ01731280) 
 - storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990) 
 - Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all"(SCGCQ01810054 port of SCGCQ01809355) 
 - EPD-PT behavior changes for Aero to support in RAID personality(SCGCQ01816139 port of SCGCQ01594176) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719) 
 - State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM(SCGCQ01853457 port of SCGCQ01853444) 
 - StorCLI hits segmentation fault on a Superdome Flex Server (with 16 MR cards in server(SCGCQ01911830 port of SCGCQ01886637) 
 - (Libmods) Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder)(SCGCQ01915314 port of SCGCQ01227144) 
 - Isolating faulty cable issue from bad drive issue for Aspen and Vail (Invader and Intruder(SCGCQ01915320 port of SCGCQ01222855) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01915841 port of SCGCQ01836749) 
 - Disk performance throttled when running MegaCli AdpEvent log dump on Aspen and Vail (Invader and Intruder(SCGCQ01921533 port of SCGCQ01220901) 
 - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982(SCGCQ01922038 port of SCGCQ01106988) 
 - LibMods : Adding the function that changing flag of full initialize completion(SCGCQ01922843 port of SCGCQ01141462) 
 - MFI Frame alignment(SCGCQ01922846 port of SCGCQ01064480) 
 - Square bracket is missing in the syntax of "set hardware device page" in storclio.(SCGCQ01929787 port of SCGCQ01224857) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526330 port of SCGCQ01274709) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01540785 port of SCGCQ01509578) 
 - Ctrl-H hang during foreign import along with app tab toggling.(SCGCQ01571937 port of SCGCQ01356240) 
 - Data Abort Exception while entering CTRL R(SCGCQ01571939 port of SCGCQ01380831) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01599436 port of SCGCQ01595698) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599461 port of SCGCQ01595717) 
 - Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245) 
 - Snapdump file user does not know the compression method(SCGCQ01624670 port of SCGCQ01616917) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628097 port of SCGCQ01609234) 
 - Patrol read state shown as aborted while it actually is paused.(SCGCQ01714666 port of SCGCQ01714264) 
 - Storcli output does not list missing PD's(SCGCQ01715372 port of SCGCQ01715114) 
 - Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01720760 port of SCGCQ01714033) 
 - Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller(SCGCQ01749927 port of SCGCQ01749795) 
 - storcli /cx/pall show command fails with older generation cards that does not support PCIe pages(SCGCQ01758163 port of SCGCQ01520816) 
 - PERC10.2:CLI:Help: Grammatical Error in Text String "/ex - specifies a enclosure where X is the enclosure device ID."(SCGCQ01768428 port of SCGCQ01764888) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817308 port of SCGCQ01817307) 
 - StorCLI should support firmware flash for SAS3 IR Controllers(SCGCQ01873578 port of SCGCQ01835627) 
 - show enclosure command is not exiting to shell(SCGCQ01874899 port of SCGCQ01814011) 
 - Storcli issuing 'add jbod drives=all' causes storcli to crash(SCGCQ01893370 port of SCGCQ01892288) 
 - Hide/Unhide command output display incorrect VD no for VDs on which the operation is not supported(SCGCQ01911848 port of SCGCQ01837932) 
 - Turn on the boodrive by storcli, HII does not reflect it, still shows "Off"(SCGCQ01915791 port of SCGCQ01816927) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01917007 port of SCGCQ01761309) 
 - PH9 PA StorCLI - /c0/eall/sal show all gives success message when no drives connected(SCGCQ01917168 port of SCGCQ01855721) 
 - Storcli: Ventura B0: BIOS Flashing Failure Observed in EFI Storcli and Multiple Tries Causes UART Unresponsive(SCGCQ01917338 port of SCGCQ01829667) 
 - Adding CLI command to display/toggle new controller property.(SCGCQ01922836 port of SCGCQ01106982) 
 - Storcli not working on large config setup when some of the drives are missing or the system has foreign config.(SCGCQ01940851 port of SCGCQ01940805) 
 - Expander FW download using storecli utility crashs.(SCGCQ01979615 port of SCGCQ01979599) 
 - Updating readme file(SCGCQ01294583 port of SCGCQ01294570) 
 - Remove sorting logic for array physical drives(SCGCQ01445612 port of SCGCQ01444666) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514530 port of SCGCQ01505055) 
 - Allow "noreset" option for IT controllers during firmware download(SCGCQ01517643 port of SCGCQ01514483) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886) 
 - Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528936 port of SCGCQ01528886) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528939 port of SCGCQ01525764) 
 - Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360) 
 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591157 port of SCGCQ01504604) 
 - Unified LibMod changes for ER : SCGCQ01504604 - Removal of MegaCLI syntax from StorCLI(SCGCQ01591158 port of SCGCQ01504610) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599464 port of SCGCQ01595709) 
 - storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595) 
 - Detailed status is not displayed on locating a drive which is not connected to IT card.(SCGCQ01599519 port of SCGCQ01571154) 
 - Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009) 
 - Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver.(SCGCQ01600151 port of SCGCQ01595698) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929) 
 - Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780) 
 - Cached IO policy(SCGCQ01627941 port of SCGCQ01607434) 
 - Space need in the output for secure erase(SCGCQ01714669 port of SCGCQ01713604) 
 - Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output(SCGCQ01718294 port of SCGCQ01718269) 
 - Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR(SCGCQ01749921 port of SCGCQ01749849) 
 - storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676) 
 - non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01760604 port of SCGCQ01698272) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760655 port of SCGCQ01735493) 
 - "storcli show snapdump" output is incorrect(SCGCQ01817270 port of SCGCQ01804779) 
 - Fails to set user defined value for delayOCR field in the SnampDump(SCGCQ01817941 port of SCGCQ01817465) 
 - Fails to set SnapDump savecount.(SCGCQ01817942 port of SCGCQ01817177) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01836905 port of SCGCQ01681538) 
 - Error message when Maximum number of VDs are reached(SCGCQ01911765 port of SCGCQ01856544) 
 - perccli /cx delete config command getting incorrect error message.(SCGCQ01911827 port of SCGCQ01850719) 
 - Unified LibMod changes : Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913460 port of SCGCQ01893074) 
 - Add security-related compilation and linker flags to StorCLI - Linux(SCGCQ01913461 port of SCGCQ01892560) 
 - Add interface in storecli that could get relearn complete status(SCGCQ01914835 port of SCGCQ01848387) 
 - 6.13_SDS : Wrong error message is displayed on trying to create R0 vd on an pre configured drive as EPD.(SCGCQ01922844 port of SCGCQ01196785) 
 - Added new commands from StorCLI(SCGCQ01922845 port of SCGCQ01134166) 
 - Unified StorCLI : Enclosure devices are part of drive list used for drive operations(SCGCQ01979534 port of SCGCQ01979483) 
 - Add /dev/sdX to StorCLI output(SCGCQ01514531 port of SCGCQ01514516) 
 - Prepare To Transport(SCGCQ01568934 port of SCGCQ00936041) 
 - CacheCade VD association returns error in Config Utility (Ctrl-R(SCGCQ01571889 port of SCGCQ01264552) 
 - .(SCGCQ01571935 port of SCGCQ01325052) 
 - Commands "/call/<x>all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562) 
 - Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605) 
 - Storcli_Aero: unable to set sasadd methodport on IT controller.(SCGCQ01628094 port of SCGCQ01609234) 
 - Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure(SCGCQ01714307 port of SCGCQ01664412) 
 - Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show"(SCGCQ01732928 port of SCGCQ01714356) 
 - controller show wbsupport reason is not listed in the cli output(SCGCQ01760590 port of SCGCQ01561704) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760636 port of SCGCQ01735493) 
 - "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017) 
 - Trying to import Secured LDs and if wrong Security Key is mentioned, Error is referring to "Pass phrase"(SCGCQ01764539 port of SCGCQ01763866) 
 - Libmods: SCGCQ01760508 Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764540 port of SCGCQ01764049) 
 - Enhance the detailed help for Firmware download and get bios command.(SCGCQ01792109 port of SCGCQ01790167) 
 - Updating ncurses library from 6.0 to 6.1(SCGCQ01837234 port of SCGCQ01836749) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01911298 port of SCGCQ01852603) 
 - perccli(007.0523.0000.0000 Jul 20, 2018(SCGCQ01914827 port of SCGCQ01874120) 
 - Incorrect Interface Details for "storcli /c0 show" command(SCGCQ01915785 port of SCGCQ01837612) 
 - Invader/Intruder: MR 6.13.1- PD FW download status help to be updated(SCGCQ01922838 port of SCGCQ01256727) 
 - Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578) 
 - Implemented to display the full Model number of the SATA drive when connected to an IT controller.(SCGCQ01528940 port of SCGCQ01525764) 
 - Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552) 
 - Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256) 
 - Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620417 port of SCGCQ01619562) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620453 port of SCGCQ01618675) 
 - Storcli does not display the complete enclosure serial number(SCGCQ01760661 port of SCGCQ01735493) 
 - PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on(SCGCQ01853459 port of SCGCQ01850418) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01869194 port of SCGCQ01867354) 
 - StorCLI should not display SED property when using IT-HBA(SCGCQ01915857 port of SCGCQ01589445) 
 - Unified StorCLI Phase 9: Prints are seen in the console when SL_GET_CTRL_INFO fails from SL in uEFI platform(SCGCQ01917167 port of SCGCQ01866548) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525771 port of SCGCQ01520567) 
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321) 
 - This feature is not supported on this Controller" is displayed multiple times.(SCGCQ01599446 port of SCGCQ01595717) 
 - Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481) 
 - controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689) 
 - Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618501 port of SCGCQ01547929) 
 - syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675) 
 - Invalid return status from Storcli(SCGCQ01731842 port of SCGCQ01731797) 
 - Unified StorCLI LibMods 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01749416 port of SCGCQ01720952) 
 - DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01760603 port of SCGCQ01714443) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01813396 port of SCGCQ01583223) 
 - Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602(SCGCQ01853371 port of SCGCQ01775616) 
 - Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server(SCGCQ01916018 port of SCGCQ01867354) 
 - Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567) 
 - Spell error in /call/dall split mirror output.(SCGCQ01599466 port of SCGCQ01595709) 
 - Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618) 
 - Compilation errors while compiling parser module(SCGCQ01600565 port of SCGCQ01600563) 
 - CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640) 
 - Unified StorCLI 7.6 - Moving CLI's VIB toolchain to 6.0 and workbench to 3.5.7(SCGCQ01745530 port of SCGCQ01720947) 
 - Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255) 
 - Collecting snapdump through StorCli (Libmods(SCGCQ01594187 port of SCGCQ01589854) 
 - WWN for NVME PDs is reported as NA with MR(SCGCQ01749397 port of SCGCQ01731279) 
 - Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command(SCGCQ01758162 port of SCGCQ01676983) 
 - Spell mistake in error message for hwdev command(SCGCQ01760594 port of SCGCQ01614972) 
 - Error message-"Reached Maximum Supported virtual Disks" is displayed when no free space left create VD.(SCGCQ01764538 port of SCGCQ01760508) 
 - PERCCLI_PERC10.2-007.0512/When selecting a PD that is not configurable, it is showing "Atleast" which should be "At least"(SCGCQ01768422 port of SCGCQ01764929) 
 - StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers(SCGCQ01853405 port of SCGCQ01775602) 
 - Unified StorCLI : Drive after the enclosure is not displayed as part of /eall/sall show [all] command(SCGCQ01977760 port of SCGCQ01948579) 
 
EnhancementRequests
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01473897) 
 - Adding JSON schema for Virtual Drive level commands(SCGCQ01516772) 
 - Enhance StorCLI show file=<packagefile> to include PnP ID(SCGCQ01517431) 
 - Need Storcli support drive FW upgrade(SCGCQ01583217) 
 - displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state"(SCGCQ01681538) 
 - Add ForceHCB option in StorCLI for IT controllers(SCGCQ01718946) 
 - Switch attached NVMe HW RAID support for Supermicro backplanes(SCGCQ01720819) 
 - Added customer serial number field to MFC Manufacturing 2 structure(SCGCQ01873417) 
 - MR API changes to support EKMS over OOB(SCGCQ01874035) 
 - Add new error code for tampered or invalid controller(SCGCQ01885686) 
 - Interrupt coalsecing setting per group of 8 replies queues (h/w VF registers(SCGCQ01886424) 
 - [MR 7.8] API change to export "disable least latency mode"(SCGCQ01887495) 
 - HDET: Support smp passthrough storeliboob (API changes requirement(SCGCQ01916035) 
 - Add secure boot key update complete event(SCGCQ01928254) 
 - Add Board Support Package Image Type to MR_IMAGE_TYPE(SCGCQ01931637) 
 - Support dynamically add/remove controller in Storelib IT for MCTP over PCIe(SCGCQ01934815) 
 - Fix MR_CTRL_INFO to support backward compatibility(SCGCQ01946548) 
 - Add a new log event used whenever the snap dump properties are modified.(SCGCQ01963328) 
 - Add a bit for atomic descriptor capable(SCGCQ01965047) 
 - Add Downgrade Firmware function in Storcli(SCGCQ01583223) 
 - Add support for TCG Opal 2.0 compliant SAS/SATA HDDs, SAS/SATA HDDs operations in StorCLI(SCGCQ01593849) 
 - StorCLI JSON 4.0 compliant schema creation for Phy (including mux and lane) level commands(SCGCQ01594119) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01615487) 
 - UNMAP/TRIM/WRITESAME for NVMe devices for R0/1/EPD/JBOD(SCGCQ01727113) 
 - Adding JSON schema for Drive Group and Foreign configuration commands(SCGCQ01531269) 
 - Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01583226) 
 - Libmods : Improving SAS bus test coverage by checking PHY error count when linking at 12G speed using a SAS loopback.(SCGCQ01615540) 
 - To add restriction on personality change requests from RAID to eHBA and eHBA to RAID(SCGCQ01721528) 
 - StorCLI JSON 4.0 compliant schema creation for Enclosure, BBU and CacheVault commands(SCGCQ01576130) 
 - Add get VPD command support to StorCLI in OS environment(SCGCQ01852603) 
 - Improve PERCcli Terminology When in eHBA Mode(SCGCQ01628424) 
 - Porting StorCLI Huawei Criteo requirement from 7.4 to 7.5(SCGCQ01761309) 

007.0525.0000.0000  - Moderate Impact/Low Probability of Occurrence
--------------------

Defects (16)
-.(SCGCQ01753405)
- Grammatical mistakes in Perccli Un-supported RAID level warning message.(SCGCQ01714033)
- Correcting the grammatical errors in firmware's MFI Stat messages.(SCGCQ01717315)
- Enclosure show status command gives success but nothing is shown.(SCGCQ01731280)
- One of the requirement for Criteo is to display JBOD-WB (EPD) to OS drive mapping.(SCGCQ01804763)
- Turn on the boodrive by storcli, HII does not reflect it, still shows "Off".(SCGCQ01816927)
- Incorrect Interface Details for "storcli /c0 show" command.(SCGCQ01837612)
- Two MCTP error codes in slerrors.h show same offset code 0x7098.(SCGCQ01627548)
- Space need in the output for secure erase.(SCGCQ01713604)
- seg fault is seen when when we try to generate CRC errors using megamon.(SCGCQ01841619)
- Missing punctuation in Perccli delete config message.(SCGCQ01698226)
- Personality Behavior Modes:Command returns failure when setting non-RAID behavior modes.(SCGCQ01713265)
- non-RAID:HII:CLI:Dedicated Hot Spare creation displays incorrect disk group association.(SCGCQ01698272)
- DHS:Unable to add dedicated Hot Spare drive to specified DG.(SCGCQ01714443)
- WWN for NVME PDs is reported as NA with MR.(SCGCQ01731279)
- Storcli: UEFI shell error display-Error: Unsupported File open Mode.(SCGCQ01837752)
- perccli /cx delete config command getting incorrect error message.(SCGCQ01851908 port of SCGCQ01850719)
- storclio need to support proprietary i2c controller mode.(SCGCQ01801679 port of SCGCQ01732990)
- State of the tape drive should be displayed as "JBOD" when FW state is MR_PD_STATE_SYSTEM.(SCGCQ01853457 port of SCGCQ01853444)
- Phase 7 - Drive Listing Is Not In Order for "/c0 show" & "/c0 show all".(SCGCQ01810054 port of SCGCQ01809355)
- storcli /cx/pall show command fails with older generation cards that does not support PCIe pages.(SCGCQ01758163 port of SCGCQ01520816)
- Unified StorCLI Phase 8 : NVMe and SAS Drive's WWN is incorrect for IT Controller.(SCGCQ01749927 port of SCGCQ01749795)
- storcli did not show current profile when connection in invalid config.(SCGCQ01760598 port of SCGCQ01713676)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760655 port of SCGCQ01735493)
- Unified StorCLI 7.7 : StorCLI doesn't report failure status when nopad image flashing fails via completeflash command in MR.(SCGCQ01749921 port of SCGCQ01749849)
- Unified StorCLI 7.7 : Unconfigured BAD drives are not displayed in /c0 show output.(SCGCQ01718294 port of SCGCQ01718269)
- "Cached Virtual Drives" displayed in /c0/dall show cachecade without the table.(SCGCQ01760676 port of SCGCQ01537017)
- controller show wbsupport reason is not listed in the cli output.(SCGCQ01760590 port of SCGCQ01561704)
- Updating ncurses library from 6.0 to 6.1.(SCGCQ01837234 port of SCGCQ01836749)
- Drive Listing Is Not In Order for "/c0 show" & "/c0/eall/sall show".(SCGCQ01732928 port of SCGCQ01714356)
- Storcli does not display the complete enclosure serial number.(SCGCQ01760661 port of SCGCQ01735493)
- Unified StorCLI : StorCLI doesn't display OS Name for Windows Server 2019 server.(SCGCQ01869194 port of SCGCQ01867354)
- PH9 PA StorCLI - Tape drive entry not seen at "Requested boot drive" field after set bootdrive on.(SCGCQ01853459 port of SCGCQ01850418)
- Libmod changes for StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers - SCGCQ01775602.(SCGCQ01853371 port of SCGCQ01775616)
- Add Downgrade Firmware function in Storcli.(SCGCQ01813396 port of SCGCQ01583223)
- Spell mistake in error message for hwdev command.(SCGCQ01760594 port of SCGCQ01614972)
- StorCLI doesn't call SL_EXIT_LIB in VMware environment for MR Controllers.(SCGCQ01853405 port of SCGCQ01775602)
- Unified StorCLI 7.7 : StorCLI should not issue SL_SET_LIB_PARAMETERS command.(SCGCQ01758162 port of SCGCQ01676983)

EnhancementRequests (30)
- API Changes for Driver/FW DCMD HandShake.(SCGCQ01841266)
- RTTrace Enable/Disable API changes.(SCGCQ01830211)
- Criteo: API changes reversal.(SCGCQ01760512)
- RTTrace API Changes.(SCGCQ01745568)
- API changes needed to support eHBA product series.(SCGCQ01727346)
- Create sanitize events.(SCGCQ01713708)
- MPI 2.5: Add MaxEnclosureLevel field to BIOS Page 1.(SCGCQ01570730)
-.(SCGCQ01593479)
-.(SCGCQ01761309)
- displaying ONFI flash state command: storcli /cx/cv show all New Feild: "NVCache state".(SCGCQ01681538)
- API change for Switch attached NVMe HW RAID support for Supermicro backplanes.(SCGCQ01697667)
- Mixing Rules for SED and non-SED drives to create non-secure array with controller security enabled.(SCGCQ01757538)
- Unmap: Define new API for enhanced UNMAP support.(SCGCQ01758062)
- Adding API bit to indicate whether forced personality change is supported or not.(SCGCQ01762153)
- Unmap: Define new events for enhanced UNMAP support [MR7.8].(SCGCQ01803319)
- Deprecate the snap dump fields that are no longer needed for MR_SNAP_DUMP_PROPERTIES structure.(SCGCQ01816724)
-.(SCGCQ01818580)
- Add the API to clear all the snap-dumps from firmware.(SCGCQ01824135)
- API change to provide learn complete timestamp.(SCGCQ01845269)
- Added Support for Triggering SnapDump.(SCGCQ01848759)
- Add secure boot support.(SCGCQ01792416)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- Including The Time Stamp for every Snap Dump created in the firmware.(SCGCQ01797424)
- Aero FW - Reporting SSD wear gauge values for OEM specific customers.(SCGCQ01798686)
- [MR 7.8] API change to return apt failure status for a personality change request.(SCGCQ01853480)
- Added new events for unmap policy changes.(SCGCQ01871912)
- MPI 2.5: Add OEMRD field to SAS Enclosure Page 0.(SCGCQ01553021)
- API Changes - After Vision PSOC FW update, applications should ask the user for power cycle instead of reboot.(SCGCQ01765150)
- To add restriction on personality change requests from RAID to eHBA and eHBA to RAID.(SCGCQ01721528)
- Add get VPD command support to StorCLI in OS environment.(SCGCQ01852603)


0007.0507.0000.0000- Moderate Impact/Low Probability of Occurrence
-------------------

Defects (75)
- Profile Mgmt API Changes.( SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- Enable WB support via API.(SCGCQ01405242)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json..(SCGCQ01413239)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON..(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- Remove unsupported Ethernet code for IT controller from CLI.(SCGCQ01448979)
- Show command is not processed for IT firmware and IT complete flash images in big endian server.(SCGCQ01451940)
- storcli /c0/e123/s1 show poh shows drive info on IT controller.(SCGCQ01456171)
- Storcli displays "success" and "failure" both when trying to enable UNMAP on RAID5 using SSDs..(SCGCQ01462396)
- Storcli verbose help for Unmap has spelling mistakes.(SCGCQ01462401)
- Updating the JSON Schema for the SCSI Unmap feature.(SCGCQ01465745)
- Storcli: Instance Validation Failed between "system-schema.json" and "show" JSON..(SCGCQ01467131)
- Part 1 : Fixing coverity issues - Resource leaks and Illegal comparison.(SCGCQ01470420)
- Instance Validation Failed between "virtual-drive-config-schema.json" and "add vd " JSON.(SCGCQ01471852)
- Start/Stop locate on a invalid enclosure returns success.(SCGCQ01480910)
- Detailed help contents were not present for most of the IT download options..(SCGCQ01483760)
- Spelling errors in the "/cx restart" command..(SCGCQ01486415)
- Storcli: Instance Validation Failed between "controller-flash-component-erase-schema.json" and "flasherase" JSON..(SCGCQ01506022)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show_profile" JSON..(SCGCQ01506052)
- CLI help does not reflect the new command to create an ePD.(SCGCQ01639583)
- Phase3 Beta PCIe: Loading SLOOB fails with error message "ExitLib failed for SAS IT Controller!! rval 0x801A".(SCGCQ01292964)
- Instance Validation is failing for mentioned commands..(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output..(SCGCQ01423447)
- Incorrect PNP ID format is displayed in EFI for firmware and complete flash images.(SCGCQ01448990)
- PH6 Ventura Pre-Alpha - StorCLI - "show file = fw.bin" command usage is not updated in help.(SCGCQ01460588)
- Showing empty error msg in CLI when Unmap not supported is returned by FW..(SCGCQ01464580)
- Storcli: Instance Validation Failed between "enclosure-schema.json" and "/call/eall show" JSON..(SCGCQ01467146)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/call/jbodall show" JSON..(SCGCQ01467694)
- PH6 Ventura Pre-Alpha - StorCLI - /c0 show all - Capabilities for supported drives seen only SAS/SATA, NVMe not found.(SCGCQ01480920)
- PH6 Ventura - Storcli crashed in Win2016 when "storcli64.exe J" is executed.(SCGCQ01488062)
- Instance Validation Failed between "controller-termlog-schema.json" and "set termlog=off" JSON..(SCGCQ01506041)
- Readme file have no mention of PD and JBOD level command support..(SCGCQ01507421)
- Checking in VBAS compliation changes.(SCGCQ01630324)
- PERCCLI ePD personality behavior command is still an available option and has not been removed.(SCGCQ01639798)
- Storcli: VD creation fails from storcli in presence of 0KB bad drive.(SCGCQ01713240)
- Operating system is not displaying the version in EFI for any of command in cli.(SCGCQ01410613)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" command.(SCGCQ01438214)
- MR7.5: StorCLI reports Multipath ON during set but OFF during show commands.(SCGCQ01440234)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- PH6 Ventura Pre-Alpha - StorCLI - /cx/ set bootdrive = on/off command not updated in help page.(SCGCQ01460582)
- Schema addition for "show file=<image>" command.(SCGCQ01461209)
- PH6 Ventura Pre-Alpha -- "storcli64.exe /c0 compare ssid ver = 2 J" command crashes and utility stopped working in Win2016.(SCGCQ01462593)
- MR 7.5_UNMAP : UNMAP support info is not shown in controller supported operations and VD properties.(SCGCQ01464562)
- PH6 Ventura StorCLI - Pre-Alpha - /cx compare detailed help is not giving complete information.(SCGCQ01464762)
- Instance Validation Failed between "controller-patrolread-set-schema.json" and "/c0 set pr excludevd=1" JSON.(SCGCQ01472845)
- Instance Validation Failed between "drive-operations-patrolread-schema.json" and "/call/e65/sall show patrolread".(SCGCQ01473344)
- Grammatical error in Perccli warning message during FW Flash.(SCGCQ01686670)
- OpROM's and their versions are not displayed for 8,32,and 64 MB IT complete flash images.(SCGCQ01449785)
- Part 3 : Fixing coverity issue : Resource leaks.(SCGCQ01472797)
- Storcli: Instance Validation Failed between schema and JSON output for many scenarios with one common error.(SCGCQ01506038)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- Incorrect help description for erase and download completeflash commands.(SCGCQ01470263)
- Instance Validation Failed between "controller-jbod-schema.json" and "add jbod" JSON..(SCGCQ01472802)
- Storcli: Instance Validation Failed for direct attached drive commands..(SCGCQ01472833)
- Check for supported pages for firing drive SCSI commands.(SCGCQ01474325)
- No error description when start/stop locate fails on the drive from StoreLIBIT library.(SCGCQ01480900)
- IT command to set sasadd and other set operations shows success for an MR controller.(SCGCQ01483753)
- Changing CV/BBU state algorithm according to the updated design document..(SCGCQ01388595)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Storcli: Instance Validation Failed between "controller-linkconfig-schema.json" and "show linkconfig" json..(SCGCQ01465446)
- Coverity libmods issues - Resource leaks and Wrong sizes.(SCGCQ01472195)
- Storcli: Instance Validation Failed between "enclosure-drive-detailed-schema.json" and "/call/eall/sall show all" json..(SCGCQ01473334)
- Unified StorCLI does not support erasing of persistent config pages in host for IT controllers.(SCGCQ01466766)
- Storcli: Instance Validation Failed between "jbod-show-schema.json" and "/c0/jbodx show" JSON..(SCGCQ01472821)
- UEFI StorCLI should detect controller when UEFI driver is not present and when FW is in ready state.(SCGCQ01489472)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output..(SCGCQ01414749)


EnhancementRequests (174)
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- Modify event string APIs for MISSING and OFFLINE LDs.(SCGCQ01628177)
- New configuration params added for EPD-PT devices.(SCGCQ01599607)
- MR API change request to Enable/disable the parallel PD FW update feature based on PNP ID’s.(SCGCQ01595347)
- Implement Snapdump debugging capability.(SCGCQ01567770)
- Add "Incompatible with Profile" event.(SCGCQ01289924)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType..(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01615487)
- JSON schema for Drive level commands.(SCGCQ01445435)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01216848)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.6: Add new firmware download type (CPLD IMAGE).(SCGCQ01305760)
- MPI 2.6: add NVMe SGL Data Block descriptor alignment flag.(SCGCQ01339864)
- MPI 2.6: Add Aero PCI Device IDs.(SCGCQ01373008)
-.(SCGCQ01389581)
- MPI 2.6: Add ControllerResetTO to PCIe Device Page 2.(SCGCQ01416498)
- MPI 2.6: Add new reason code to PCIE Device Status Change Event.(SCGCQ01416515)
- Add Test Link Diagnostic API.(SCGCQ01436268)
- Add a new structure to provide OEMs ability to switch to select either I2C or PCIe as an out of band transport.(SCGCQ01445048)
- MPI 2.6: PCIe Device Page 2 reporting Namespace Optimal IO Boundary(NOIOB) for NVMe devices.(SCGCQ01449138)
- Provide OEMs ability to select either I2C or PCIe as an out of band transport.(SCGCQ01450245)
- Update description of MR_DCMD_CTRL_PERSONALITY_SET Dcmd.(SCGCQ01467149)
- Added MR_MFC_DEFAULTS.NVMeAbortTO and MR_MFC_DEFAULTS.NVMeMaxControllerResetTO.(SCGCQ01532045)
- Add support for API fields to report SED type of PD.(SCGCQ01587230)
- Add OnOff parameter in Properties2 of Structure MR_CTRL_PROP to enable/disable mix of Enterprise & Opal SED drives.(SCGCQ01593520)
- NVDATA parameter to OPAL SED.(SCGCQ01614689)
- Added a new interface between driver-aops to indicate if 64 bit SGL support is enabled.(SCGCQ01620350)
- Add new MFI Status to block requested operation due to existing controller configuration.(SCGCQ01670135)
- Change the mr.h API comment showing the new return status for the - MR_DCMD_PD_GET_INFO.(SCGCQ01670234)
- Add support to defeature Cached I/O policy.(SCGCQ01581032)
- New events for PR/CC conflicts and sector size mismatch.(SCGCQ01227051)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- Removing the NMR storcli commands from storcli..(SCGCQ01445268)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- MPI 2.6: Device side PCIe SRNS flag.(SCGCQ01276256)
- Checking of VBAS make file DataPro of Univ_viva_libmods.(SCGCQ01488176)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
- Removing the NMR storcli commands from storcli..(SCGCQ01445418)
-.(SCGCQ01428114)
-.(SCGCQ01423509)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452987)
- Add NVMe device related changes.(SCGCQ01034678)
- Provide end-user ability to select either I2C or PCIe as an out of band transport.(SCGCQ01452986)
- Add boot drive selection support in Stor-CLI.(SCGCQ01445896)
- Improve PERCcli Terminology When in eHBA Mode.(SCGCQ01628424)
-.(SCGCQ01466805)
- StorCLI Libmods - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF.(SCGCQ01448954)
- StorCLI - Ventura LD de-allocation support on SAS/SATA SSDs through UNMAP/WRITE SAME on non-PARITY, non-DIF volumes.(SCGCQ01447799)
- Adding JSON schema for JBOD and Drive level commands.(SCGCQ01445308)
- Add support for IT Firmware images and IT Completeflash images to "show file=<file>" command.(SCGCQ01436882)

CSETActivities (57)
- StorCLI should not display SED property when using IT-HBA.(SCGCQ01600142 port of SCGCQ01589445)
- Enumeration of drives in NGM[PERCCLI Implementation / HBA330 Mini Mezz](SCGCQ01600137 port of SCGCQ01458174)
- Allow "noreset" option for IT controllers during firmware download.(SCGCQ01599545 port of SCGCQ01514483)
- Storcli show displays OS Version appended with Technical Preview.(SCGCQ01478448 port of SCGCQ01474457)
- Storcli: Instance Validation Failed between "controller-cc-schema.json" and "show consistencycheck" JSON(SCGCQ01456168 port of SCGCQ01451170)
- Phase 5 : Command "storcli /c0 show all" crashes with drives connected to SAS3.5 IT controller(SCGCQ01452992 port of SCGCQ01452982)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json(SCGCQ01430285 port of SCGCQ01430237)
- SLT : Requesting user to enter the allocated response length of SMP request page(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini(SCGCQ01275669 port of SCGCQ01275496)
- Unified StorCLI 7.6 : Creation of VD aborts StorCLI when FW returns error code for MR_DCMD_CFG_READ DCMD(SCGCQ01600150 port of SCGCQ01588245)
- This feature is not supported on this Controller" is displayed multiple times(SCGCQ01599461 port of SCGCQ01595717)
- Storcli may not be able to show the RAID controller in some special situation(SCGCQ01500340 port of SCGCQ01392154)
- Port linkspeed is displayed in a different JSON object for NVMe drives(SCGCQ01438288 port of SCGCQ01436920)
- Changing ini file name to storelibconfit.ini(SCGCQ01275670 port of SCGCQ01275496)
- Cutlass Phase 16 Storcli: Partner device ID should be suppressed under ./storcli /c0/eall show for multipath connections(SCGCQ01625114 port of SCGCQ01606780)
- Support only Dell SAS IT Controllers with PERCCLI(SCGCQ01618493 port of SCGCQ01547929)
- Storcli_Aero: Storcli not able to detect controller at EFI shell without Avago MR driver(SCGCQ01600151 port of SCGCQ01595698)
- Storcli returns error for show file commands when parsing MR images eventhough the command was successful(SCGCQ01600149 port of SCGCQ01529009)
- Detailed status is not displayed on locating a drive which is not connected to IT card(SCGCQ01599519 port of SCGCQ01571154)
- storcli controller show all lists EPD's in VD list(SCGCQ01599486 port of SCGCQ01556595)
- Spell error in /call/dall split mirror output(SCGCQ01599464 port of SCGCQ01595709)
- Unified StorCLI 7.6 : Read SBR fails with pre-ventura controllers(SCGCQ01539390 port of SCGCQ01539360)
- Implemented to display the full Model number of the SATA drive when connected to an IT controller(SCGCQ01528939 port of SCGCQ01525764)
- Libmod: checking-in the changes forLibmods for SCGCQ01525764(SCGCQ01528935 port of SCGCQ01528886)
- Storcli display Operating System without space for Linux version(SCGCQ01479250 port of SCGCQ01478526)
- Adding excludevd option to the help file of patrolread command(SCGCQ01445710 port of SCGCQ01443435)
- Updating readme file(SCGCQ01294583 port of SCGCQ01294570)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status(SCGCQ01003523 port of SCGCQ00950453)
- Libmod Changes for Defect SCGCQ01595640 (CLI does not report Serial number for Lenovo D1224 Enclosure)(SCGCQ01714307 port of SCGCQ01664412)
- Storcli_Aero: unable to set sasadd methodport on IT controller(SCGCQ01628094 port of SCGCQ01609234)
- Update help contents for jbod delete(SCGCQ01625945 port of SCGCQ01624605)
- Un-supported command displayed for "storcli64.exe /call show sasaddress"(SCGCQ01620412 port of SCGCQ01619562)
- Commands "/call/<x>all" return inappropriate message or segfault when both MR and IT controllers are connected(SCGCQ01599483 port of SCGCQ01561703)
- Profile Management: Storcli - Add support for WB bit in profile management show(SCGCQ01454856 port of SCGCQ01445628)
- Instance Validation is failing for mentioned commands.(SCGCQ01445724 port of SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01436736 port of SCGCQ01423447)
- Application crashes while executing storcli64.exe /c0/dall set hidden=on(SCGCQ01599467 port of SCGCQ01571256)
- Storcli PR help execution delay is missing when PR running continuously(SCGCQ01537216 port of SCGCQ01534552)
- Change in RAID levels displaying in controller show all command(SCGCQ01511611 port of SCGCQ01509578)
- Upgrading the ncurses library from 5.4 to 6.0 in view of security vulnerabilities(SCGCQ01500111 port of SCGCQ01499900)
- DriveID and errormsg are coming improper on drive POH command when failed(SCGCQ01447688 port of SCGCQ01443683)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01430044 port of SCGCQ01414749)
- syntax error while executing "storcli64.exe /c0 get firmware ? "(SCGCQ01620437 port of SCGCQ01618675)
- controller show all command is not listing the Battery information(SCGCQ01599459 port of SCGCQ01561689)
- Incremented devicename is programmed for all the phy's in IT controller(SCGCQ01599449 port of SCGCQ01548481)
- Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01526326 port of SCGCQ01526321)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500006 port of SCGCQ01336460)
- Unified StorCLI 7.0.1 : Programming VPD to MPB regions(SCGCQ01500000 port of SCGCQ01336460)
- Instance Validation Failed between "controller-properties-schema.json" and "show" json output.(SCGCQ01452142 port of SCGCQ01451156)
- Updating pre-ventura SBR fails with "hwdevice" command(SCGCQ01438351 port of SCGCQ01438214)
- CLI does not report Serial number for Enclosure.(SCGCQ01714296 port of SCGCQ01595640)
- Get VPD from MPB region is failure, but overalll status shows success(SCGCQ01599481 port of SCGCQ01589618)
- Unconfigured Good PD is showing as belonging to Disk Group 0.(SCGCQ01525774 port of SCGCQ01520567)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01500132 port of SCGCQ01399793)
- Updating the Diag results as per new API changes(SCGCQ01537265 port of SCGCQ01537255)
- Storcli show preservedcache displays incorrect VD size on a missing VD(SCGCQ01500316 port of SCGCQ01447792)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01456036 port of SCGCQ01419754)


0007.0409.0000.0000- Moderate Impact/Low Probability of Occurrence
-------------------
fixes:
- Profile Mgmt API Changes.(SCGCQ00883008)
- MR_RAID_CTX_G35 has one too many bits.(SCGCQ00886417)
- Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO.(SCGCQ00927738)
- The code had events with repetitive ID and some structures clashing.(SCGCQ00948535)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23.(SCGCQ01001936)
- CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4.(SCGCQ01014835)
- 800C error when execting Get MFC default function.(SCGCQ01037840)
- StorCLIO states wrong OS version for Windows 2016.(SCGCQ01274715)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311728)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01311846)
- Fixing Error Handling issues and Resource leak.(SCGCQ01319395)
- Fix for Libmod files having potential loop errors.(SCGCQ01320336)
- Cisco - CSCvd90485 - StorCLI error message incorrect when disabling LargeIO support.(SCGCQ01322003)
- EFIStorcli(1.21.12):Number of blocks in VD info is blank when queried for VD info from EFIStorcli.(SCGCQ01355452)
- Factory command is deducting the remanfacturing license even for the first time manufacturing.(SCGCQ01364604)
- Updated the Help.(SCGCQ01375059)
- controller show all command is not listing the JBODs when controller is in JBOD personality.(SCGCQ01383816)
- Controller mode reported as "Undefined" in JBOD mode in show profile output.(SCGCQ01384238)
- storcli is giving error when issuing the command dall show mirror.(SCGCQ01384690)
- Misleading message "Reboot" when erase or completeflash done in MR ventura.(SCGCQ01385373)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01385425)
- Fixing out of bounds in libmods.(SCGCQ01385430)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388177)
- Save and restore with spanned volumes is throwing an error array index invalid.(SCGCQ01388543)
- PH5 StorCLI - Pre-Alpha - Show all reports NVMe drive linkspeed as "UNKNOWN".(SCGCQ01392511)
- Strocli: controller-shutdown-restart-schema.json is not in JSON format.(SCGCQ01412756)
- Storclio and storclif dispays windows version wrong for Windows 10 OS.(SCGCQ01413011)
- Storcli: Instance Validation Failed between "controller-sgpioforce-schema.json" and "set sgpioforce" JSON output.(SCGCQ01413017)
- Storcli: Instance Validation Failed between "controller-properties-schema.json" and "show" json.(SCGCQ01413239)
- Not even or regular in pattern of drive order display in storcli.(SCGCQ01415875)
- Storcli: Instance Validation Failed between "controller-profile-schema.json" and "show profile" JSON.(SCGCQ01423458)
- Port linkspeed is displayed in a different JSON object for NVMe drives.(SCGCQ01436920)
- PERC10 - VD is deleted after discarding preserved cache with CLI.(SCGCQ01300897)
- Need to handle FW return code change for profile management success case.(SCGCQ01307320)
- Unified StorCLI 7.3 : Fixing resource leaks - Part 1.(SCGCQ01319405)
- PH4 Ventura PA - StorCLI - show command prints wrong information for Fury C0 in OEL6.8.(SCGCQ01321477)
- Non-operational state of FW when EFI driver is absent causing segmentation fault.(SCGCQ01324749)
- CLI reports failure when issuie DPM commands.(SCGCQ01333085)
- PH4 Ventura - StorCLI - Indentation errors observed in output while programming invalid length VPD file.(SCGCQ01346041)
- Fixing unchecked return values.(SCGCQ01385377)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01388610)
- Battery Capacitance is displayed incorrectly across different applications.(SCGCQ01389922)
- LinkSpeed is unknown for PCIe devices under Port Information headline.(SCGCQ01404583)
- Storcli: Instance Validation Failed between "controller-eghs-schema.json" and "set eghs" JSON output.(SCGCQ01412764)
- Storcli: Instance Validation Failed between "controller-securitykey-schema.json" and "set securitykey" JSON output.(SCGCQ01412948)
- Storcli: Instance Validation Failed between "controller-time-schema.json" and set time json.(SCGCQ01413222)
- This is a syntactical error where a comma was added.(SCGCQ01414744)
- Storcli: Additional string displayed in "Show wbsupport" output.(SCGCQ01415208)
- Instance Validation is failing for mentioned commands.(SCGCQ01415355)
- Instance Validation Failed between "controller-detailed-properties-schema.json" and "show all" JSON output.(SCGCQ01423447)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
- StorCLI - Show command thorws error "failed to get information from host" in APM (ARM) CentOS.(SCGCQ01321460)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01359018)
- IIC mode string was used to append in case of error. I2C must be used.(SCGCQ01392046)
- Storcli 07.403.00.00 is showing Linkdown for all Phys in c0/pall show command.(SCGCQ01404219)
- Storcli: Instance Validation Failed between "controller-events-schema" and "delete events" JSON output.(SCGCQ01410438)
- Storcli: Instance Validation Failed between " controller-termlog-schema" and "delete termlog" JSON output.(SCGCQ01411534)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "set flus how riteverify" JSON output.(SCGCQ01412771)
- Strocli: controller-ASO-schema.json is not in JSON format.(SCGCQ01413261)
- Instance Validation Failed between "controller-ASO-schema.json" and "show ASO" json.(SCGCQ01430237)
- Updating pre-ventura SBR fails with "hwdevice" comman.(SCGCQ01438214)
- Adding excludevd option to the help file of patrolread command.(SCGCQ01443435)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
- PH4 StorCLI - Segmentation fault observed with show command when fury/cutlass/marlin connected in FreeBSD11.0.(SCGCQ01312757)
- Unified LibMods 7.3 : Fixing resource leaks and missing return statments - Part 2.(SCGCQ01319407)
- Changing of PatrolRead Excludevd property from cli.(SCGCQ01348042)
- CLI is not showing Insight Drives with correct Enclosure/Chassis position.(SCGCQ01373639)
- Removing the memory leaks in dequelog command.(SCGCQ01411544)
- Storcli: Instance Validation Failed between "controller-coercion-schema.json" and "set coercion" JSON output.(SCGCQ01412758)
- Strocli: controller-HDD-SSD-thermalpollinterval-schema.json is not in JSON format.(SCGCQ01412934)
- Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
- Reverting back SL_MAX_OS_DRIVE_COUNT value to 300.(SCGCQ01114306)
- Fixing Out of Bounds access and Resource leak.(SCGCQ01304875)
- Inconsistencies between the applications for manage link speed.(SCGCQ01389856)
- Storcli: Instance Validation Failed between "controller-supportssdpatrolread-schema.json" and set supportssdpatrolread json.(SCGCQ01413106)
- Storcli: Instance Validation Failed between "controller-bios-schema.json" and "show bios" JSON output.(SCGCQ01413263)
- Assign VDs suboption in cachecade VD creation is not assigning the intended VDs.(SCGCQ01419754)
- StorCLI: Spindown help syntax is misleading.(SCGCQ01421610)
- Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
- StorCLI Device Interface Information field doesn't reflect inteface of actual device attached to an IT controller.(SCGCQ01352149)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01378900)
- Correcting yacc rule for bbus show gasguage data command.(SCGCQ01389891)
- Strocli: controller-config-schema.json is not in JSON format.(SCGCQ01412748)
- Strocli: controller-detailed-properties-schema.json is not in JSON format.(SCGCQ01413255)
- DriveID and errormsg are coming improper on drive POH command when failed.(SCGCQ01443683)
- Correcting yacc rule of slaveaddress for command hwdevice.(SCGCQ01389890)
- Storcli: Instance Validation Failed between "controller-personality-schema.json" and "set_personality" JSON output.(SCGCQ01412943)
- Storcli: Instance Validation Failed between "controller-smartpollinterval-schema.json" and "set smartpollinterval" json.(SCGCQ01413018)
- Storcli: Instance Validation Failed between "controller-flushwriteverify-schema.json" and "show flushwriteverify" JSON.(SCGCQ01423452)
- The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL.(SCGCQ01015024)
- storclif64 can not create prl11 across 2 enclosure using 32 pds.(SCGCQ01295289)
- StorCLI crashes when VPD file with VPD_Length 0 is tried to update.(SCGCQ01340557)
- Removing the NMR command for setting SCAPVPD.(SCGCQ01389451)
- Storcli: Instance Validation Failed between "controller-perfmode-values-schema.json" and "set perfmode" JSON output.(SCGCQ01412938)
- Instance Validation Failed between "controller-freespace-schema.json" and "show freespace" JSON output.(SCGCQ01414749)

EnhancementRequests:
- MPI2: Add TargetModeAbort by initiator device handle.(SCGCQ00337167)
- New fault code for routine synchronous reset.(SCGCQ01264142)
- MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually.(SCGCQ00574358)
- MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag).(SCGCQ00414050)
- MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply.(SCGCQ00396414)
- MPI2: Add OEM Identifier to BIOS Page 1.(SCGCQ00357228)
- MPI2: Use Slot Information during Port Enable Event Replay option.(SCGCQ00356796)
- MPI2: Add new TargetModeAbort AbortType to only abort Command IUs.(SCGCQ00345215)
- MPI v2.6: Additional request and reply descriptor formats.(SCGCQ00259613)
- API changes for CR55 - PCIe lane/link speed.(SCGCQ01222700)
- API change for Simplified RAID10 Creation.(SCGCQ01222698)
- API Changes Required for Specific OEM Backplane functionality.(SCGCQ01218406)
- API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli.(SCGCQ01215334)
- MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0.(SCGCQ01213028)
- MPI 2.5: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01208954)
- API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue.(SCGCQ01203751)
- MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP.(SCGCQ01180886)
- MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY.(SCGCQ01146597)
- MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES.(SCGCQ01141251)
- MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters.(SCGCQ01139344)
- MR 6.13: Add a new control command to fetch ROC temperature data over I2C.(SCGCQ01137627)
- MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public).(SCGCQ01114969)
- MPI 2.5: Add new connector types.(SCGCQ01085073)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ01002367)
- MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout".(SCGCQ00996127)
- MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1.(SCGCQ00853162)
- MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable.(SCGCQ00791885)
- MPI 2.5: add WWID to BIOS Page 3.(SCGCQ00785208)
- MPI 2.5: update copyright info.(SCGCQ00728066)
- MPI 2.5: BIOS Page 1 additions.(SCGCQ00700829)
- MPI 2.5: distribute Target Command Buffers Received across multiple reply queues.(SCGCQ00685820)
- MPI 2.0: Add product-specific Flag bit to Clean Tool.(SCGCQ00569175)
- Add type BIOS for HashImageType.(SCGCQ00566306)
- Identify physical location of a target device.(SCGCQ00523879)
- MPI 2.5: add reserved fields to IO Unit Page 7 for future use.(SCGCQ00477817)
- MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps".(SCGCQ00471293)
- MPI 2.5: Signed images for FWDownload.(SCGCQ00469990)
- MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL.(SCGCQ00438437)
- MPI 2.5: Toolbox Console Text Display Tool.(SCGCQ00415512)
- Allow Protection Information bit for IR Volume Create.(SCGCQ00385306)
- MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply.(SCGCQ00357551)
- MPI 2.6: add PCIe Device Config Pages.(SCGCQ00345271)
- MPI 2.6: PCIe Switch Config Pages.(SCGCQ00345270)
- MPI 2.6: PCIe Topology Change List Event.(SCGCQ00345266)
- MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event.(SCGCQ00345260)
- MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors.(SCGCQ00338506)
- MPI 2.6: PCIe IO Unit Page 0 & 1 definitions.(SCGCQ00336383)
- MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1.(SCGCQ00310439)
- MPI 2.6: update SGL chapter to include PCIe.(SCGCQ00294131)
- MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request.(SCGCQ00294055)
- MPI 2.6: NVMe Encapsulated request.(SCGCQ00264759)
- MPI 2.6: SOP Encapsulated request.(SCGCQ00264755)
-.(SCGCQ01421997)
- Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers.(SCGCQ01399793)
- RPM -verify report error after installing storcli RPM package for linux.(SCGCQ01373354)
- Adding the JBOD personality with EPD passthrough support.(SCGCQ01368469)
- Added the support for EPD-PT creation and operations on a EPD-PT.(SCGCQ01368465)
- List pending profile details of the controller.(SCGCQ01346308)
-.(SCGCQ01291037)
- MPI 2.6 Add Atomic Request Descriptor capability.(SCGCQ00227735)
- MPI 2.6: add IO Unit Control Request.(SCGCQ00345258)
- MPI 2.6: PCIe Link Config Pages.(SCGCQ00345272)
- MPI 2.6: Enclosure Management.(SCGCQ00345273)
- Device Info field for PCIe devices.(SCGCQ00353339)
- MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request.(SCGCQ00360843)
- MPI 2.6: new family values for ProductID fields.(SCGCQ00360952)
- MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11.(SCGCQ00363600)
- Modified address space bits.(SCGCQ00397136)
- MPI 2.6: Add PCIe IO Unit Page 4.(SCGCQ00397563)
- MPI 2.6: Add board power fields to IO Unit Page 7.(SCGCQ00397572)
- MPI 2.6: Add support for SAS Persistent Connections.(SCGCQ00397577)
- MPI 2.6: Add NVMe SGL support.(SCGCQ00398256)
- MPI 2.6: Add NVMe SGL support to IEEE SGL.(SCGCQ00432541)
- MPI 2.6: System Interface Register Set update.(SCGCQ00464402)
- Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request.(SCGCQ00480292)
- MPI 2.6: shutdown operation for IO Unit Control Request.(SCGCQ00496998)
- MPI 2.6: Add supported link rates and widths for PCIe devices.(SCGCQ00564281)
- MPI 2.6: Add additional NVMe AccessStatus codes.(SCGCQ00574070)
- MPI 2.6: Add BootFlags field to Firmware Image Header.(SCGCQ00601869)
- MPI 2.6: Add new FLASH region types.(SCGCQ00619371)
- MPI 2.6: Added an additional signature value for the firmware image header.(SCGCQ00623271)
- MPI 2.6: additional AccessStatus values for PCIe Device Page 0.(SCGCQ00664957)
- MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages.(SCGCQ00680527)
- MPI 2.6: Extend Task Management - Target Reset Method to include PCIe devices.(SCGCQ00686666)
- MPI 2.6: Add device off flag to SCSI Enclosure Processor messages.(SCGCQ00776177)
- MPI 2.6: New Phy event codes added to Ventura.(SCGCQ00789600)
- MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough.(SCGCQ00813389)
- MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura.(SCGCQ00827088)
- MPI 2.6: add PCI Device ID's.(SCGCQ00828497)
- MPI 2.6: methods to report Active Cable power problems.(SCGCQ00831588)
- MPI 2.6: SRIOV support for PCIe devices.(SCGCQ00852827)
- MPI 2.6: Update Flash Signature..(SCGCQ00852831)
- profile management API.(SCGCQ00867953)
- MPI 2.6: add new feature to control NVMe SGL format.(SCGCQ00872169)
- Mega API modifications needed for RMW-FP and Cache bypass features in Ventura.(SCGCQ00875328)
-.(SCGCQ00878757)
- Merging api_overrides mega_api files with the files in the Mega_API development stream.(SCGCQ00883262)
- MPI 2.6: Update Ventura family device ids to match latest EDS.(SCGCQ00915256)
- MPI 2.6: update Marlin-class device IDs.(SCGCQ00915336)
- MPI 2.6: Remove all SOP references.(SCGCQ00925839)
- Ventura: de-feature AHCI.(SCGCQ00941620)
- MPI 2.6: Remove all AHCI references.(SCGCQ00948258)
- MPI 2.6: Add support for SAS-4 and PCIe-4.(SCGCQ00948955)
- MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0.(SCGCQ00949638)
- MPI 2.6: add LinkNum field to the PCIe Link configuration pages.(SCGCQ00954619)
-.(SCGCQ00987840)
- MPI-2.6: backend PCIe feature initialization status reporting.(SCGCQ01009104)
- MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request.(SCGCQ01013930)
- MPI2.6: Fix defines that are not unique within the first 32 characters.(SCGCQ01015826)
- MPI 2.6: direct reporting of negotiated PCIe link width and speed.(SCGCQ01017027)
- MPI 2.6: Backend SRIS mode enable flag.(SCGCQ01018687)
- MPI2.6: Reserve ExtPageTypes for Dragon.(SCGCQ01020473)
- MR_CTRL_INFO expansion from 2K to 4K.(SCGCQ01023741)
- mega api changes for ibuttonless PR.(SCGCQ01059740)
- MPI2.6: Add x16 PCI support for Marlin family products.(SCGCQ01063009)
- MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page.(SCGCQ01071374)
- Profile Management Changes to support requestedProfileID and optimisedProfile.(SCGCQ01075821)
-.(SCGCQ01082303)
-.(SCGCQ01085954)
- MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout".(SCGCQ01092340)
- MEGA_API Changes to incorporate new IO subtype to support redirect cached IO.(SCGCQ01094549)
- MPI 2.6: Add Sea Arch class and Product IDs.(SCGCQ01116837)
- MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file.(SCGCQ01133839)
- MPI2.6: Added new image type and flash region definitions.(SCGCQ01136127)
- MPI 2.6: Add new clean tool options.(SCGCQ01141732)
- MPI 2.6: Add two new reason codes to Active Cable Exception Event Data.(SCGCQ01146583)
- Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register.(SCGCQ01188725)
- MR7.1. Add MR API bit to indicate the profile is NVMe Only profile.(SCGCQ01213092)
- MPI2.6: Mfg7 support for arbitrary starting slot number.(SCGCQ01213267)
- MPI 2.6: Add new firmware download type (CBB BACKUP).(SCGCQ01258005)
- MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply.(SCGCQ00988360)
- MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses.(SCGCQ00466819)
- always print StorCLI version information at beginning/top of output.(SCGCQ01396733)
- StorCLI JSON 4.0 compliant schema creation for Contoller level commands.(SCGCQ01365177)
- New command in CLI OEM mode to select either PCIE or I2C as an out of band transport.(SCGCQ01353429)
- Add support to allow Device names greater than 107.(SCGCQ01039328)
- MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs.(SCGCQ00397568)
- MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit.(SCGCQ00884740)
- MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks.(SCGCQ00922213)
- Profile Management: Storcli - Add support for WB bit in profile management show.(SCGCQ01445628)
-.(SCGCQ01428114)
- Add ability to field upgrade CPLD on HBA boards.(SCGCQ01283646)
- Add NVMe device related changes.(SCGCQ01034678)
- Block the MR commands being fired to IT controllers and vice versa from StorCLI.(SCGCQ01315301)
- Unified StorCLI 7.3 : Display serial number information in StorCLI.(SCGCQ01309079)
- Unified StorCLI 7.3 : ARM EFI support to Unified StorCLI.(SCGCQ01292973)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)

CSETActivities:
- StorCLI firmware download to multiple target devices fails to every other device.(SCGCQ01417390 port of SCGCQ01391339)
- Unified StorCLI 7.3 : Validate data to be read for controller recovery commands.(SCGCQ01399705 port of SCGCQ01359018)
- MR 6.14-CLI: Auto Learn Period Mismatch between CTRL-R and StorCLI..(SCGCQ01396719 port of SCGCQ01391037)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391818 port of SCGCQ00940993)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01304925 port of SCGCQ00915484)
- Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01300741 port of SCGCQ01290216)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01298614 port of SCGCQ01295830)
- Mr_6.12_Arm_EFI_CLI:storcli.ef /c0/vall show bbmt dose not display the corrected and uncorrected values.(SCGCQ01293051 port of SCGCQ01059790)
- MR_6.12_Arm_EFI-CLI:storcli.efi /c0/vall set ssdcaching=on/off does not apply for all the Vd's at a time.(SCGCQ01293028 port of SCGCQ01060315)
- MR_6.12_Arm_EFI-Synchronous Exception on running set vpd command with a wrong input file.(SCGCQ01293027 port of SCGCQ01059798)
- Hercules StorCLI: Progress EVents are not logged in StorCLI.(SCGCQ01291546 port of SCGCQ01288785)
- SLT : Requesting user to enter the allocated response length of SMP request page.(SCGCQ01202087 port of SCGCQ01202030)
- Changing ini file name to storelibconfit.ini.(SCGCQ01275669 port of SCGCQ01275496)
- Block OCR after Clearing NVRAM.(SCGCQ01396705 port of SCGCQ01389485)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391828 port of SCGCQ00976651)
- Tape drive connected to MR controller should not take NVMe speeds in to consideration.(SCGCQ01389395 port of SCGCQ01388610)
- Unified LibMod changes for SCGCQ01351495[Tape drive support to StorCLI].(SCGCQ01385205 port of SCGCQ01351565)
- Perccli Snapshot is Enabled error when deleting VDs.(SCGCQ01384442 port of SCGCQ01378900)
- CISCO SQA2 - LR - 1U 10 HDD - StorCLI - /c0/eall/sall start locate throws success message with no LED activity.(SCGCQ01350423 port of SCGCQ01349575 )
- Global Hot Spares shows as TR in storcli DG query when TR is activated on DG.(SCGCQ01332915 port of SCGCQ01047789)
- Correcting error messages for transport errors.(SCGCQ01332859 port of SCGCQ01093152)
- Storcli needs to be fixed for maximum TR info in ctrl show all.(SCGCQ01332851 port of SCGCQ01112673)
- Storclif64 does not return non zero error code on failure.(SCGCQ01320515 port of SCGCQ01318824)
- MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01318368 port of SCGCQ01273381)
- Need to handle FW return code change for profile management success case.(SCGCQ01318326 port of SCGCQ01307320)
- MR6.12_Arm_storcli.efi:Error Message Wrong on start learn cycle failure scenario.(SCGCQ01293158 port of SCGCQ01039757)
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292796 port of SCGCQ01290596)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392548 port of SCGCQ01392529)
- Storcli shows CV as optimal When Predictive Failure Bit is set.(SCGCQ01392541 port of SCGCQ01392529)
- MR6.12_FW : With spun down PDs and primary path broken, FW does not allow creation of VDs.(SCGCQ01332806 port of SCGCQ01035520)
- Adding a sub option to skip the self-test while reading the POH as per customer request.(SCGCQ01292051 port of SCGCQ01074274)
- MR_6.12_ARM_Storcli.efi:storclio.efi /c0 set pcilinkspeed=3 success and set as 3%.(SCGCQ01293159 port of SCGCQ01058298)
- SLT displays XYRATEX enclosure many fields information as "Unsupported", when we fire a command Get Enclosure Status.(SCGCQ01003523 port of SCGCQ00950453)
- Update Attribution Language - Copyright, Trademark, Confidentiality to Avago.(SCGCQ00793391 port ofSCGCQ00787940)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345297 port of SCGCQ01344843)
- Factory settings changes for Transport as per new MFC_DEFAULTS in API.(SCGCQ01332916 port of SCGCQ01044891)
- CLI to maintain consistency in the properties/attributes including case between MR and IT.(SCGCQ01309547 port of SCGCQ01308958)
- The command "Storcli /c0/vall del" its deleting the VDs along with EPDs as well.(SCGCQ01305204 port ofSCGCQ00915484 )
- perccli lists PDs in the wrong order - sometimes.(SCGCQ01292797 port of SCGCQ01290596)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391817 port of SCGCQ00940993)
- StorCli should display 128 byte inquiry for drives connected to IT controller including tape.(SCGCQ01388560 port of SCGCQ01388177)
- Factory command is deducting the remanfacturing license even for the first time manufacturing .(SCGCQ01364653 port of SCGCQ01364604)
- Trying to Create Logical disks with UBAD drives gives wrong Failure Message from Storcli.(SCGCQ01358889 port of SCGCQ01356294)
- StorCLI displays "Next Learn Time" incorrectly.(SCGCQ01345296 port of SCGCQ01344843)
- Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332905 port of SCGCQ01214152)
- C240-M5: Segmentation Fault observed when tried to delete a SWR VD from Version (Max5): 3.1(0.102).( SCGCQ01324969 port of SCGCQ01309488)
- Cisco - CSCvd49859 - Set VD hidden on a already hidden VD message is not correct from StorCLI.(SCGCQ01301733 port of SCGCQ01295830)
- Libmods: Second OCR request not triggered, fired when first OCR request about to finish, but O/P shows success(SCGCQ01290216).(SCGCQ01300727 port of SCGCQ01300721)
- Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01292007 port of SCGCQ00940993)
- ER:SCGCQ00940993-Libmod Changes:Custom PERC CLI for Dell OEM Solutions group.(SCGCQ01391827 port of SCGCQ00976651)
- storcli craches with drive show all command for some specific SATA drive.(SCGCQ01386881 port of SCGCQ01385425)
- Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01383787 port of SCGCQ01351495)
- Transport command is including all when only shared is requested, where it should be failed.(SCGCQ01332907 port of SCGCQ01093145)
- Libmods: SCGCQ01214152 - Storcli fails with segmentation fault (core dumped) with foreign import.(SCGCQ01332872 port of SCGCQ01249484)
- [Lenovo] Storcli may not be able to show the RAID controller in some special situation.(SCGCQ01392462 port of SCGCQ01389914)
- Storcli SegFault -HUU update utility doesn't detect SBMezz if Foreign Config PD exist.(SCGCQ01332850 port of SCGCQ01155309)
- Erase [excludemfg] file=<> command hangs when executed on non-op/jumpered/OCR disabled operational MR Ventura controllers.(SCGCQ01315413 port of SCGCQ01311846)
- PH4 StorCLI -Cutlass-9305-16e FW download failed on Linux/Windows OS platforms.(SCGCQ01311820 port of SCGCQ01311728)
- MR6.12_Arm_Storcli.efi:No error message shown when deleting securitykey fail.(SCGCQ01293161 port of SCGCQ01039756)
- MR6.12_Arm_EFI-CLI:Having multiple Raid volumes created,CLI lists extra entries and all operations on VD’s fails thereafter.(SCGCQ01293053 port of SCGCQ01047493)


0007.0209.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Fixes:
     - MegaCli and StorCli can not manage both Liberator (and prior) and TB controllers in the same system under FreeBSD with the mf(SCGCQ00355536)
 - Update VD emulation feature in StorCLI Libmods module to sync with latest APIs.(SCGCQ00357913)
 - StorCLI does not display drive information behind the Blackjack (Alta) interposer correctly(SCGCQ00357948)
 - In paged view the text " Press Enter to continue" should be changed to " Press any key to Continue"(SCGCQ00359629)
 - Code clean up in libmods and sysefi files are added(SCGCQ00359998)
 - Storcli is returning error with show(SCGCQ00360040)
 - StorCLI: Not able to set pr property includessds as onlymixed on Liberator cacheoffload controller(SCGCQ00360814)
 - iMr_Fury_StorCli:4K Drive size shown wrong in Esxi4.1U3(SCGCQ00362216)
 - storcli /c0/d0 show " in that legend missing for "Dgrd/pdgd/Onln/ofLn/Rbld"(SCGCQ00362717)
 - The legend for the PD List table exceeds 80 char limit.(SCGCQ00363455)
 - storcli query for displaying controller properties is showing status , as failure.(SCGCQ00363522)
 - iMR_Inv_6.1:StoreCLI- StoreCLI reports wrong Emulation type for VDs(SCGCQ00364097)
 - StorCLI failed to delete a VD that is just created under Windows 2008(SCGCQ00364248)
 - Reports wrong diskgroup size while querying controller level properties(SCGCQ00364622)
 - UEFI, the O/P of <storcli /c0 show all>"Current Controller Date/Time" & "Current System Date/time" are not in proper format(SCGCQ00364735)
 - Storcli displays incomplete serial number for some SSDs(SCGCQ00366000)
 - Certain controller features displayed under "show all" exceeds 80-char limit.(SCGCQ00372155)
 - StorCLI crashed when run on a Windows 2008 64-bit with 24GB of RAM and 66 drives attached(SCGCQ00374735)
 - StorCli shows Power Saving Option as enabled, despite IBM Flatwood controller having power saving option completely disabled.(SCGCQ00377364)
 - portings of AdpRestart command(SCGCQ00378135)
 - StorCLI-Legacy:'adpbootdrive get' fails to get bootdrive information.(SCGCQ00378828)
 - Not able to get paged view of StorCLI output on VM-Ware Platform(SCGCQ00379104)
 - Cfgclr command fails without force option in Sparc OS(SCGCQ00396303)
 - storcli crashes on having a non PI drive and trying to create pi vd on all the drive(SCGCQ00413789)
 - EFI_ Storcli: Cannot set vpd file on controller, EFI hangs and cannot proceed for further operations until reboot(SCGCQ00423832)
 - Megacli crashes after invoking any command in SGI system with one 9280-8e and 2 quad port qlogic FC cards.(SCGCQ00438350)
 - Onfi_patch_6.0:Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6.(SCGCQ00442610)
 - SWR_1.34(SCGCQ00442652)
 - Raptor_Galaxy:State of the Shielded Drive is not displayed using storcli command(SCGCQ00467502)
 - Raptor_Galaxy_Tencent:Tencent Storcli detecting the H710 PERC card.(SCGCQ00475583)
 - Storcli internal errors should return with 1001, but its coming as -1(SCGCQ00479843)
 - Try to create a Exclusive VD, but after creation it still shows as Shared VD.(SCGCQ00484560)
 - MR6.2 : Storcli shows incorrect "Bus" information when "/c0 show all" is run(SCGCQ00518201)
 - Unable to make R10 through Ctrl R using 4k drives(SCGCQ00518579)
 - PPC64 :: MR Liberator :: Storcli Version 1.09.01 is showing wrong Creation Date and Time in VD properties(SCGCQ00569935)
 - MR_Inv_6.3_PPC:Storcli- Retreiving LDBBM info through storcli is failing on SLES11 SP2 PPC64(SCGCQ00574835)
 - "/cx/ex show phyerrorcounters" gives core dump on freeBSD 32 and 64 bit.(SCGCQ00644123)
 - Storcli : unable to set patrol read delay(SCGCQ00645195)
 - MR6.4_StorCLI_240VD: StorCLI crashes on issuing /c1 set cc=conc delay=10 starttime=2014/12/12 12 excludevd=0(SCGCQ00649324)
 - Storlib header file checkin and make compatible changes in CLI code.(SCGCQ00653742)
 - StorCLIO_1.09.09 : Not able to set subOEMid in Rhel 5.10 x64 bit.(SCGCQ00674131)
 - While creating cachecade vd with one SAS-SSD;Raid 1 option is also enabled(SCGCQ00712171)
 - H330: Firmware Crash is hit while creating the Raid1 vd without drives selected(SCGCQ00725192)
 - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties(SCGCQ00730505)
 - 6.6_StorCli: StorCli lists all cascaded enclosures at position 0.(SCGCQ00756647)
 - FW breaks in iMR when excluding VD's from CC(SCGCQ00758770)
 - SupportMaxRate SATA is not listed in PD allowed operations.(SCGCQ00759178)
 - SED adapterOperation detailed is not shown in detailed show controller properties(SCGCQ00759183)
 - Adapters are not listed in sorted order.(SCGCQ00759969)
 - MR6.6: Segmentation fault (Core Dumped) in CLI when setting any invalid value for PR start time(SCGCQ00760398)
 - /c0 show all does not list hwCfg information as compared to MegaCLI.(SCGCQ00760752)
 - Storclio : Different error code is coming for 'set pcilinkspeed' in VMware 4.1U3(SCGCQ00762663)
 - StorCLI is not updated with the error Message for all new MFI_STAT added in mfistat.h(SCGCQ00765712)
 - StorCLI VMware Binary not displaying detailed description for phyerrorcounters of enclosures(SCGCQ00765762)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a VD which is associated with a CacheCade VD(SCGCQ00772243)
 - Active operation(s) is coming as none when virtual drive erase is in progress.(SCGCQ00779789)
 - MR6.6:StorCLI shows incorrect information about "Cache Vault Flash Size"(SCGCQ00782882)
 - "cpybck" help is not coming in Legends(SCGCQ00784808)
 - VD level hide/unhide is not possible through storcli in PPC(SCGCQ00785400)
 - MFCdefaults : DisableHII option needs to be include in getShowDefaults()(SCGCQ00792232)
 - Comparing an array to null is not useful: "rawSmartData != NULL"(SCGCQ00793374)
 - MR_6.7_STROCLI: Command "./storcli64 /c0/ex/sx reset phyerrorcounters" fails in RHEL6.6 PPC64(SCGCQ00794394)
 - .(SCGCQ00800878)
 - Deallocation of the same memory more than once(SCGCQ00802031)
 - Memory leak happening in failure case since not freeing before returning error code.(SCGCQ00804588)
 - Out-of-bounds access and array delete misuse(SCGCQ00804680)
 - MR_6.7_ Storcli: "Storcli /cx/eall/sall show " gives no enclosure found if two enclosures are connected in multipath scenario(SCGCQ00805547)
 - Not able add new VD in Drive Group(SCGCQ00813314)
 - MR_6.7: Storcli Command "./storcli /c0/v2 set accesspolicy=RmvBlkd " fails for a blocked source VD.(SCGCQ00814939)
 - Storcli cannot create R10 in iMR with 6 or 8 drives per span.(SCGCQ00827049)
 - Storcli crashes instead of showing error message on enabling caching on Source VDs and C(SCGCQ00827299)
 - storcli /call show all fails with "command invalid"(SCGCQ00830269)
 - New PD_Degraded media events are not logging correctly in PPC(SCGCQ00837342)
 - Profile Mgmt API Changes(SCGCQ00883008)
 - MR_RAID_CTX_G35 has one too many bits(SCGCQ00886417)
 - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO(SCGCQ00927738)
 - The code had events with repetitive ID and some structures clashing(SCGCQ00948535)
 - Controller detection fails in EFI environment with MR Ventura card(SCGCQ01001372)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23(SCGCQ01001936)
 - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again(SCGCQ01014835)
 - 800C error when execting Get MFC default function(SCGCQ01037840)
 - ThinkServer: Cyborg [Purley] Sotrcli (007.0022.0000.0000) cannot show the correct PCI bus/dev/func number for Invader and Ven(SCGCQ01087936)
 - Serial Number for drives were having spaces when displaying in Storcli(SCGCQ01126284)
 - No ISE Capable field(SCGCQ01148693)
 - MR7.1_NVMe:Segmentation fault seen on storcli while generating controller info with preserved cache(SCGCQ01193175)
 - Ventura-Beta: Storcli/Storclif utilities hit Segmentation fault when foreign configuration is present(SCGCQ01198698)
 - Fixing Resource leaks(SCGCQ01205356)
 - resource validation before de referencing(SCGCQ01206104)
 - Fixing resource leaks in libmods(SCGCQ01208044)
 - Fixing resource leak and pointer to local variable coverity defect in libmods(SCGCQ01209393)
 - Fixing Logically dead code and Wrong size arguments in CLI(SCGCQ01209414)
 - Unified Libmods StorCLI 7.1:Fixing resource leaks-Part 4(SCGCQ01209473)
 - Fix for resource leak in system config show(SCGCQ01210133)
 - MR7.1_NVMe: comma missing between RAID10 and RAID60 in the RAID Level Support at /c0 show all output(SCGCQ01214415)
 - Storcli does not show "NVME" in supported Drives.(SCGCQ01215383)
 - some of the drive properties is not shown properly on querying the drive info through storcli(SCGCQ01229923)
 - Unified StorCLI 7.1:Incorrect usage of STORCLIO and STORCLIF macros(SCGCQ01234217)
 - NVMe PD SMART DATA shows all 0's(SCGCQ01236052)
 - StorCLIO states wrong OS version for Windows 2016(SCGCQ01274715)
 - Individual Phy information on an IT works, when given with multiple Phys it says "Unsupported Command".(SCGCQ01275381)
 - When invalid enclsoure is specified as user input , the output is not correct(SCGCQ01275687)
 - IT show all command displays Physical Drive Information headline wihtout table when no drive is connected(SCGCQ01276688)
 - Unified StorCLI 7.2:Windows only:Drive properties headline gets truncated during drive show all command(SCGCQ01280928)
 - StorCLI: Not able to detect Liberator Controller on FreeBSD 9.0(64-bit)(SCGCQ00362421)
 - PCI Info for FreeBSD needs to be indicated as "N/A"(SCGCQ00365632)
 - Vmware CLI fails to set the phy linkspeed(SCGCQ00371445)
 - System halts on issuing storcli commands in EFI Environment.(SCGCQ00374336)
 - PERC9:Storcli ld info command displays R10 vd Span Depth to 1.(SCGCQ00374979)
 - StorCli_MR: While Creating RAID1 with four drives command facing the "C0:BAIL_OUT at line 1354" on Flatwood Board(SCGCQ00394883)
 - core dump while issuing storcli command ./storcli /c0/fall show all.(SCGCQ00448094)
 - Some Numeric values in CLI o/p comes in Hex format(SCGCQ00481474)
 - Unable to insert a drive after setting a drive as 'Missing' .(SCGCQ00490620)
 - Some sparc structures missing for storcli.(SCGCQ00504585)
 - MR Liberator : PPC SERVERGY Server : MonTask: line 541 in file ../../raid/raidpci.c(SCGCQ00567761)
 - PPC64 :: MR Liberator :: All commands of StorCli is failing with segmentation fault after creating a GlobalHotSpare(SCGCQ00579658)
 - storecli reports wrong size on 3000MB VD(SCGCQ00644545)
 - Cannot create a VD smaller than 800MB with 4K drives(SCGCQ00649962)
 - MR6.4: Storcli show command does not display all the controllers plugged into the server(SCGCQ00653672)
 - Add support bits for uneven-span and SSHA support(SCGCQ00755063)
 - MR_6.6_Storcli: Storcli reports supercap state 'unknown' while learn is happening on the controller.(SCGCQ00758101)
 - Exception with command /co show badblocks or "storcli /cx flasherase"(SCGCQ00758924)
 - SSM-FLASh drives property is displayed for regular drives.(SCGCQ00759290)
 - Support details are not shown in /c0 show all for discard cache (stalling LD deletion)(SCGCQ00759959)
 - MR_6.6: StorCLI showing incorrect value for next Schedule time for consistency check after disabling the CC(SCGCQ00760385)
 - MR 6.6 Prealpha2 Storcli:Similar PCI address(BDF number) is displayed for multiple controllers connected to FreeBSD 9.3.(SCGCQ00761937)
 - StorCLI /c0 show all command does not reflect the discard vd delete filed(SCGCQ00764658)
 - StorCLI shows CacheBypass Size and CacheBypass Mode feature enabled against a CacheCade VD(SCGCQ00765714)
 - StorCLI shows wrong "Number of blocks" for a 65.5TB VD size(SCGCQ00765759)
 - Patrol read delay is showing wrong value when set to continuous(SCGCQ00767347)
 - Showing wrong creation date for Autoconfigured virtual drives(SCGCQ00767363)
 - Storcli errors are printing in a different line.(SCGCQ00771626)
 - Storcli has option to set PR maxconcurrentpd but show is not present(SCGCQ00772302)
 - vpdpage should be read from 4 bytes to get serial number of drive(SCGCQ00772332)
 - GB scale to be added while showing CacheCade size in CLI(SCGCQ00778577)
 - MR6.6_CLI_FreeBSD: Displaying incorrect Driver name(SCGCQ00779800)
 - CTRL-R:2 iMR Card in same System hitting Montask(SCGCQ00783357)
 - Readability : Output string need to be updated for supportForceTo512e in show all command(SCGCQ00792202)
 - The HDD firmware revision is shown blank for few drives connected.(SCGCQ00793761)
 - MR_6.7_STROCLI: "./storcli64 /c0/ex show phyerrorcounters" gives segmentation fault in RHEL6.6 PPC64(SCGCQ00794393)
 - Explicit null dereferenced in rmdatamf.cpp causing wrong result.(SCGCQ00795335)
 - Resource leak(SCGCQ00804745)
 - .(SCGCQ00811452)
 - Unified StorCLI:EFI:Duplicate instances of Controller gets added to the ControllerIdList pointer(SCGCQ00936672)
 - Unified StorCLI 7.1:Coverity fixes(SCGCQ01206205)
 - Fix for profile management support check bit(SCGCQ01208103)
 - Unified StorCLI 7.1:Fxing resource leaks-Part 3(SCGCQ01209411)
 - Unified Storcli: Fixing resource leak issues(SCGCQ01209413)
 - SAS3.5 Ventura(SCGCQ01219196)
 - Discrepancy while installing and uninstalling of latest Storcli Package(SCGCQ01234153)
 - StoreCLI unified for Ventura version cannot display direct attached disk serial number information.(SCGCQ01280169)
 - pall compare shows the current linkspeed on MR controllers(SCGCQ01282376)
 - Need to handle FW return code change for profile management success case(SCGCQ01307320)
 - MegaCLI adpgetpciinfo returns a static Bus Number value "17d0"(SCGCQ00357263)
 - iMR_Inv_6.1:StorCLI- StorCLI does not show 'Unsupported/Blocked' state for 4K drives even though FW is not supporting 4K(SCGCQ00384644)
 - StorCli_MR: While creating VD using default values FW allows read policy as"Ra=Read Ahead Adaptive" as against PR-317400(SCGCQ00397663)
 - MR6.1: Hamlin: Is VD Emulated=Yes when emulationType=1(SCGCQ00424978)
 - storcli /c0 show is not listinf SWR controller(SCGCQ00454971)
 - Pcli: Pcli crashes while try to set securitykey for controller.(SCGCQ00471116)
 - Raptor Galaxy : Storcli(SCGCQ00475562)
 - Command "./Storcli /call/eall/sx set offline" fails with ERRcode1001 and ERRmsg drive not found.(SCGCQ00503981)
 - Wrong size of CacheCade VD is getting displayed after making one PD offline(SCGCQ00505771)
 - Some characters missing while querying for VD properties with having 64 VD's on a controller.(SCGCQ00529763)
 - Storclio_1.09.00:Fails to set SubOEMID on Solaris OS .(SCGCQ00568073)
 - MR_Inv_6.3_PPC:Storcli-WWN is showing blank for SAS PDs on SLES11 SP2 PPC64(SCGCQ00572800)
 - PPC64 :: MR Liberator :: ./storcli64 /c0 show dequeuelog file command failing with segmentation fault(SCGCQ00581416)
 - MR : on querying PR status, storcli hits segmentation fault.(SCGCQ00601775)
 - /c0 set cc=conc command fails with iMR card.(SCGCQ00603174)
 - storelib header file changes porting(SCGCQ00609942)
 - MR_6.4_StorCli_EFI: Storcli.efi crashes for iMR card.(SCGCQ00674023)
 - Storcli doesn't show SN of Samsung SSD 200/400/800 in SWRAID version 1.32(SCGCQ00674969)
 - storcli /c0 show all is not displaying "support vd hide" and "support HOQrebuild" feilds and legends are not displayed for HD(SCGCQ00695070)
 - In Windows and Linux only controller grouping is working but not sorting(SCGCQ00752000)
 - Boot Volume details is shown in Megacli but not with storcli.(SCGCQ00759187)
 - ASO count mismatch in show ASO w.r.t ASO in storcli show all cmd(SCGCQ00779806)
 - Reviewing the Code AdataMfi, RmDataMf and VdDataMf files.(SCGCQ00785918)
 - Missing the Display of the property temperatureCtrl.(SCGCQ00792264)
 - When Supercap SOH is reported bad, CLI still see the Supercap status as "Optimal"(SCGCQ00794760)
 - Explicit null dereferenced in vddatamf.cpp (getVdDetldInfo)(SCGCQ00795336)
 - fisResBuffer memory allocation is not considering the failure case(SCGCQ00796206)
 - Memory not freed which can cause leak(SCGCQ00804554)
 - Varailble need to be freed before returning in all failure case(SCGCQ00804650)
 - IDA show incorrect RAID controller type information(SCGCQ00806966)
 - MR_6.8_Storcli: Cachevault flash size shows differently for different commands in storcli under RHEL6.6 PPC64(SCGCQ00837197)
 - Read policy should be 'NORA' for IMR controller instead of 'none'(SCGCQ00840372)
 - ASO no mismatch between the commands 'storclif show' and 'storclif /c0 show aso'(SCGCQ01081111)
 - MR7.1_NVMe: Post NVMe VD Creation, SAS VD Creation of any Raid Level (Except R0) is not allowed(SCGCQ01127464)
 - Ventura: OEMID is shown as LSI in scheduled tasks on querying controller info.(SCGCQ01157723)
 - Removing Unused and logically dead code in storcli(SCGCQ01204045)
 - Remove all the manufacturing/Factory commands from end customer CLI tool(SCGCQ01206492)
 - Unified StorCLI 7.1-Fixing resource leaks in IT controller framework and command processors-Part2(SCGCQ01207685)
 - NVMe 7.1:Failure description string is empty in storcli(SCGCQ01234083)
 - Second OCR request not getting triggered, fired when first OCR request about to finish, but O/P shows success.(SCGCQ01290216)
 - iMR_Inv_6.1:StoreCLI-StoreCLI does not give proper message while trying to create 33rd VD on iMR FURY controller(SCGCQ00364332)
 - MR: not able to create PRL11 using 96 drives.(SCGCQ00381100)
 - StorCLI-Invader : The "coercion" mode is not in sync with the legacy values.(SCGCQ00383043)
 - Raptor Galaxy:No of blocks displayed for a VD remains same for all VD sizes.(SCGCQ00465956)
 - StorCLI reports controller status as 'OK' when Arctrus controller(9361-8i) booted in safe mode(SCGCQ00523370)
 - MR_Inv_6.3_PPC:Storcli- Storcli gives 'Segmentation fault' while retriving 'advanced software options' on SLES11 SP2 PPC64(SCGCQ00574287)
 - MR6.4_StorCLI: c0 show controller health is failing(SCGCQ00627672)
 - Add adapterOperation support details in /c0 show all for Emulationtype.(SCGCQ00759181)
 - OEMID is coming as "Unknown" for /c0 show all(SCGCQ00759862)
 - CPLD(SCGCQ00787705)
 - CPLD UPDATE : cpld upgradableCPLD support bit need to add under hardware configuration(SCGCQ00792233)
 - rlListPtr is not handled properly in failure case(SCGCQ00796227)
 - Segmentation fault while querying for GHSP/DHSP while drive is going in shield-HSP state.(SCGCQ00820392)
 - LDViewMirror is giving segmentation fault(SCGCQ00830435)
 - Storcli shows caching is enabled on Source VD when CCVD is in offline state(SCGCQ00835758)
 - Storcli gives wrong error code with respect to FW state while converting JBOD to UG(SCGCQ00839321)
 - Checking in compilation error for Libmods(SCGCQ00919973)
 - VD Creation fails with "Invalid Arguments" error with latest FW Headers(SCGCQ01001356)
 - Coverity Fixes for Unified Storcli 7.1 stream(SCGCQ01204055)
 - PH2: Pre Alpha-Ventura B0 storcli command not exited when storcli /c1 show issued.(SCGCQ01205407)
 - Fixing resource leaks and logically dead code in cli.(SCGCQ01208101)
 - Ventura B0 PH3 StorCLI : Segmentation fault seen with show command on freebsd 10.2 X86 OS(SCGCQ01250553)
 - MR 7.2:PPC : StorCLi throws error while loading the saved configuration.(SCGCQ01273381)
 - Ventura IT show command displays all the PD's under Drive group-0 which is wrong(SCGCQ01274709)
 - StorCLI does not provide command to set HSM or HCOE SCGCQ00358662(SCGCQ00360745)
 - StorCLI cannot displays information for controller in Safe mode(SCGCQ00365950)
 - StorCLI does not show both "Current Write Policy" and "Default Write Policy" for VD(SCGCQ00408070)
 - debug prints are present when issuing /co/eall show(SCGCQ00475815)
 - PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal".(SCGCQ00518543)
 - Verify StorCLI warns on destructive operations(SCGCQ00712982)
 - /c0 show all page are having some incorrectness in controller information(SCGCQ00716584)
 - MR6.5alpha:Segmentation fault(coredump) observed on executing ./storcli /c1/v63 show all for 64th cachecade VD in ubuntu14.04(SCGCQ00729691)
 - Add adapterOperation support details in /c0 show all for cachebypassMode.(SCGCQ00757358)
 - supportCPLDUpdate support bit needs to be updated in contoller detailed information(SCGCQ00792200)
 - supportDrvActivityLEDSetting supported bit need to be update in Supported adapater Operations(SCGCQ00792211)
 - Incorrect sizeof expression in dcmdprm(SCGCQ00793354)
 - Non-array delete for objects in rmdatamf(SCGCQ00793361)
 - Storcli displays wrong native driver version on ESXi5.5 when quered .(SCGCQ00803420)
 - Variable going out of scope without freeing which causes memory leak(SCGCQ00804663)
 - Non-array delete for objects: destructors will not be called for objects in the array leading to unexpected behaviour.(SCGCQ00804672)
 - FW hangs during SVD and CCVD migration based on DDR Size(SCGCQ00809736)
 - Unified CLI:EFI:Ventura IT:Adpcount is zero when the controller is in fault state(SCGCQ01016583)
 - Ventura:CLI App stopped working on executing /c0/eall/sall delete hotsparedrive(SCGCQ01081096)
 - Reverting back SL_MAX_OS_DRIVE_COUNT value to 300(SCGCQ01114306)
 - PD related information missing for NVMe drives(SCGCQ01126564)
 - Factory settings command needs to validate the manufacturing data in the INI, and log the license details with proper time(SCGCQ01205365)
 - Unified StorCLI 7.1:IT Firmware downgrade should be supported in StorCLIO and not StorCLI(SCGCQ01232854)
 - StorCLI(SCGCQ01274554)
 - Adapter 0: Failed to start SecureErase on Virtual Drive 0 in VMware_ESXi_5.1(SCGCQ00348911)
 - iMr_Fury_StorCLi:SectorSize show as "512KB" for 512Bytes drives(SCGCQ00362070)
 - StorcLi_5.7: Remove the description for "Ra=Read Ahead Adaptive" in VD show info.(SCGCQ00396665)
 - The bootwithpinnedcache logic is backwards, both storcli and the FW are affected(SCGCQ00436107)
 - StorCli: Segmantation fault appearing in storcli when issuing /c0/fall show(SCGCQ00564008)
 - CS2.0: Ctrl-R Domain Id is not showing in controller properties(SCGCQ00622605)
 - Storcli shows two controllers in the system though you have only one cotntroller in the system.(SCGCQ00690355)
 - Remove the code related to enableVCor feild this was used for ASD and now it is not used any more.(SCGCQ00789402)
 - supportForceFlash needs to add under suported adapter operations(SCGCQ00792205)
 - Operands don't affect result in pddatamf.cpp causing wrong result(SCGCQ00795334)
 - Unchecked return value in rmdatamf.cpp (getControllerStatus)(SCGCQ00795342)
 - MR_6.7_Storcli: Storcli reports wrong tmm and scap date of manufacture under scap properties in RHEL6.6 PPC64(SCGCQ00801311)
 - LibMod changes for CTLR+R (PERC9.2) to read Disk Write Cache settings of PD.(SCGCQ00811117)
 - StorCLI 7.0015 cannot create VD using firmware 6166 under Windows 2012(SCGCQ01046368)
 - Ventura:StorCLI-EFI-StorCLI hang on Purley @ Intel/Quanta for 3408(SCGCQ01052844)
 - SAS3 Invader/Intruder-Storcli : IR card is getting detected in EFI shell(SCGCQ01081353)
 - No details of pending FW images when run StorCLI /c0 show all after update to new firmware(SCGCQ01090082)
 - Libmod changes for defect(SCGCQ01112455) storcli says failed to exit from storelib IT library while enquiring the controller info(SCGCQ01114437)
 - PH2: Pre Alpha-Ventura B0 download completeflash command fails.(SCGCQ01198721)
 - Update /sall show legend to show powersave for SSDs in addition to spun down for HDDs(SCGCQ01213236)
 - MR7.1 StorCLI misspelling of "Drive Acitivy LED" During Set(SCGCQ01229289)
 - Help for Compare linkspeed is not complete(SCGCQ01275454)
 - CLI reporting Large VD (56TB) size slightly smaller than other apps (by .001)(SCGCQ00477037)
 - Storcli /c0 show ASO fails and delay in displaying .(SCGCQ00493491)
 - Storcli reports VD Type as "Rec1" during reconstruction on SPARC.(SCGCQ00499067)
 - Command /cx/ex show phyerrorcounters gives bus error in Orcale Enterprise Linux(SCGCQ00799426)
 - Libmod changes to support profile management(SCGCQ01048228)
 - storcliF 7.23.0.0: VD shown on wrong controller in a system with 2 Talladega 16i controllers installed(SCGCQ01080627)
 - Merge of enclosure related changes for phyerror counters from 6.x(SCGCQ01123876)
 - Ventura PH3(SCGCQ01253012)
 - Compare linkspeed says unsupported when given with multiple Phys(SCGCQ01275455)
 - coverity removing out of bounds reads from code(SCGCQ01280460)
 - CSET: storelib header file checkin for the latest changes done by storelib(SCGCQ00521999)
 - StorCLI :supportDisableImmediateIO adapter properties need to be added under show all command(SCGCQ00792085)
 - Firmware error code status MFI_STAT_SECURE_SYSTEM_PD_EXISTS needs to be update in code(SCGCQ00792234)
 - Resource leak in VdDataMf scanPartitions(SCGCQ00793363)
 - Storcli can't create AHCI LDs(SCGCQ00897637)
 - Unified StorCLI:EFI:Masking the SL_GET_CTRL_INFO command when the adapter is in invalid/bad state.(SCGCQ00936676)
 - The structure name is changed from oob_i2c to oob to avoid compilation failure in OOB SL(SCGCQ01015024)
 - NVMe PD firmware flash failing (not working) as per controller logs, StorCLI show success message(SCGCQ01218214)
 - Detailed help missing for IT erase commands(SCGCQ01275474)
 - start and stop locate from storcli on IT card with multiple drive option is not working.(SCGCQ01275671)
 - Coverity: Adding checks for unchecked return values of function calls(SCGCQ01280453)
 
 Enhancement
 
 - MPI2: Add TargetModeAbort by initiator device handle(SCGCQ00337167)
 - New fault code for routine synchronous reset(SCGCQ01264142)
 - MPI2: Allow UEFI and BIOS to be Enabled/Disabled individually(SCGCQ00574358)
 - MPI2: Security Freeze Lock support during SATA Init (IO Unit Page 1 Flag)(SCGCQ00414050)
 - MPI2: Add STATUS QUALIFIER to SCSI IO Error Reply(SCGCQ00396414)
 - MPI2: Add OEM Identifier to BIOS Page 1(SCGCQ00357228)
 - MPI2: Use Slot Information during Port Enable Event Replay option(SCGCQ00356796)
 - MPI2: Add new TargetModeAbort AbortType to only abort Command IUs(SCGCQ00345215)
 - MPI v2.6: Additional request and reply descriptor formats(SCGCQ00259613)
 - API changes for CR55(SCGCQ01222700)
 - API change for Simplified RAID10 Creation(SCGCQ01222698)
 - API Changes Required for Specific OEM Backplane functionality(SCGCQ01218406)
 - API changes for PR SCGCQ01139678(SCGCQ01215334)
 - MPI 2.5 : Add support for reporting Chassis Slot to Enclosure Page 0(SCGCQ01213028)
 - MPI 2.5: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01208954)
 - API changes for PR SCGCQ01127742(SCGCQ01203751)
 - MPI 2.5 and 2.6: Need IT FW to send new event for expander failing SMP(SCGCQ01180886)
 - MR 6.12(SCGCQ01146597)
 - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES(SCGCQ01141251)
 - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters(SCGCQ01139344)
 - MR 6.13: Add a new control command to fetch ROC temperature data over I2C(SCGCQ01137627)
 - MR 7.2: Add API support to make application work with Cachecade3.0 on Ventura (Public)(SCGCQ01114969)
 - MPI 2.5: Add new connector types(SCGCQ01085073)
 - MPI 2.5: Modify "SAS IO Unit Page 4" to add a new field "SATAHintingTimeout"(SCGCQ00996127)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ00988360)
 - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1(SCGCQ00853162)
 - MPI 2.5: BIOS Page 1 BiosOptions Advanced Adapter Configuration Enable(SCGCQ00791885)
 - MPI 2.5: add WWID to BIOS Page 3(SCGCQ00785208)
 - MPI 2.5: update copyright info(SCGCQ00728066)
 - MPI 2.5: BIOS Page 1 additions(SCGCQ00700829)
 - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues(SCGCQ00685820)
 - MPI 2.0: Add product-specific Flag bit to Clean Tool(SCGCQ00569175)
 - Add type BIOS for HashImageType.(SCGCQ00566306)
 - Identify physical location of a target device(SCGCQ00523879)
 - MPI 2.5: add reserved fields to IO Unit Page 7 for future use(SCGCQ00477817)
 - MPI 2.5: obsolete "Limit SATA max rate to 1.5 Gbps"(SCGCQ00471293)
 - MPI 2.5: IOCInit multiple Reply Descriptor Post Queue addresses(SCGCQ00466819)
 - MPI 2.5: obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL(SCGCQ00438437)
 - Allow Protection Information bit for IR Volume Create(SCGCQ00385306)
 - MPI 2.6: add host page size to IOCInit Request and IOCFacts Reply(SCGCQ00357551)
 - MPI 2.6: add PCIe Device Config Pages(SCGCQ00345271)
 - MPI 2.6: PCIe Switch Config Pages(SCGCQ00345270)
 - MPI 2.6: PCIe Topology Change List Event(SCGCQ00345266)
 - MPI 2.6: add PCIe Event Data (Generic), PCIe Device Status Change Event, and PCIe Enumeration Event(SCGCQ00345260)
 - MPI 2.5: additional requirements for some IOCs that support more than 8 MSI-x vectors(SCGCQ00338506)
 - MPI 2.6: PCIe IO Unit Page 0 & 1 definitions(SCGCQ00336383)
 - MPI 2.5: obsolete the Clear SATA Affiliation bit in SAS IO Unit Page 1(SCGCQ00310439)
 - MPI 2.6: update SGL chapter to include PCIe(SCGCQ00294131)
 - MPI 2.6: add Escape Passthrough bit to IO Flags of SCSI IO Request & Target Assist Request(SCGCQ00294055)
 - MPI 2.6: NVMe Encapsulated request(SCGCQ00264759)
 - MPI 2.6: SOP Encapsulated request(SCGCQ00264755)
 - Added the new Component version for SBR in both Controller-info case and also in Pending FW images use case.(SCGCQ01093183)
 - Libmods changes for EFI support for Unified storcli(SCGCQ00923719)
 - Add set "Fail PD on SMARTer" property feature to StorCLI(SCGCQ00818101)
 - OEL Support for SPARC(SCGCQ00787923)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685010)
 - Added the library functions for the new MR API bits and LD operations.(SCGCQ00685007)
 - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI(SCGCQ00564477)
 - CSET: (Tbolt PR 211180) Punctured Block Logging Improvements(SCGCQ00342399)
 - MPI 2.6 Add Atomic Request Descriptor capability(SCGCQ00227735)
 - MPI 2.6: add IO Unit Control Request(SCGCQ00345258)
 - MPI 2.6: PCIe Link Config Pages(SCGCQ00345272)
 - MPI 2.6: Enclosure Management(SCGCQ00345273)
 - Device Info field for PCIe devices(SCGCQ00353339)
 - MPI 2.6: add Port Request bit to IoFlags field of SCSI IO Request(SCGCQ00360843)
 - MPI 2.6: new family values for ProductID fields(SCGCQ00360952)
 - MPI 2.6: move all SAS IO Unit Page 4 functionality to IO Unit Page 11(SCGCQ00363600)
 - Modified address space bits(SCGCQ00397136)
 - MPI 2.6: Add PCIe IO Unit Page 4(SCGCQ00397563)
 - MPI 2.6: PCIe Device Page 2 reporting MDTS for NVMe devs(SCGCQ00397568)
 - MPI 2.6: Add board power fields to IO Unit Page 7(SCGCQ00397572)
 - MPI 2.6: Add support for SAS Persistent Connections(SCGCQ00397577)
 - MPI 2.6: Add NVMe SGL support(SCGCQ00398256)
 - MPI 2.6: Add NVMe SGL support to IEEE SGL(SCGCQ00432541)
 - MPI 2.6: System Interface Register Set update(SCGCQ00464402)
 - Remove _SATA_TRANSMIT_PORT_SELECT_SIGNAL in IO Unit Control Request(SCGCQ00480292)
 - MPI 2.6: shutdown operation for IO Unit Control Request(SCGCQ00496998)
 - MPI 2.6: Add supported link rates and widths for PCIe devices(SCGCQ00564281)
 - MPI 2.6: Add additional NVMe AccessStatus codes(SCGCQ00574070)
 - MPI 2.6: Add BootFlags field to Firmware Image Header(SCGCQ00601869)
 - MPI 2.6: Add new FLASH region types(SCGCQ00619371)
 - MPI 2.6: Added an additional signature value for the firmware image header(SCGCQ00623271)
 - MPI 2.6: additional AccessStatus values for PCIe Device Page 0(SCGCQ00664957)
 - MPI v2.6: Added Intruder / Cutlass device IDs for manufacturing pages(SCGCQ00680527)
 - MPI 2.6: Extend Task Management(SCGCQ00686666)
 - MPI 2.6: Add device off flag to SCSI Enclosure Processor messages(SCGCQ00776177)
 - MPI 2.6: New Phy event codes added to Ventura(SCGCQ00789600)
 - MPI 2.6: Add capability to send FPDMA/NCQ commands via SATA Passthrough(SCGCQ00813389)
 - MPI 2.6: BootDeviceSelect and Host Boot changes for Ventura(SCGCQ00827088)
 - MPI 2.6: add PCI Device ID's(SCGCQ00828497)
 - MPI 2.6: methods to report Active Cable power problems(SCGCQ00831588)
 - MPI 2.6: SRIOV support for PCIe devices(SCGCQ00852827)
 - MPI 2.6: Update Flash Signature.(SCGCQ00852831)
 - profile management API(SCGCQ00867953)
 - MPI 2.6: add new feature to control NVMe SGL format(SCGCQ00872169)
 - Mega API modifications needed for RMW-FP and Cache bypass features in Ventura(SCGCQ00875328)
 - Merging api_overrides mega_api files with the files in the Mega_API development stream(SCGCQ00883262)
 - MPI 2.6: Additional PCIe Enumeration Event EnumerationStatus bit(SCGCQ00884740)
 - MPI 2.6: Update Ventura family device ids to match latest EDS(SCGCQ00915256)
 - MPI 2.6: update Marlin-class device IDs(SCGCQ00915336)
 - MPI 2.6: PCIe IO Unit Page 0 and 1 tweaks(SCGCQ00922213)
 - MPI 2.6: Remove all SOP references(SCGCQ00925839)
 - Change library name to SLIT(SCGCQ00933175)
 - Ventura: de-feature AHCI(SCGCQ00941620)
 - MPI 2.6: Remove all AHCI references(SCGCQ00948258)
 - MPI 2.6: Add support for SAS-4 and PCIe-4(SCGCQ00948955)
 - MPI 2.6: Add Enclosure Level and Connector name to PCIe device page 0(SCGCQ00949638)
 - MPI 2.6: add LinkNum field to the PCIe Link configuration pages(SCGCQ00954619)
 - MPI-2.6: backend PCIe feature initialization status reporting(SCGCQ01009104)
 - MPI 2.6: add flag to force completion queue entry return for NVMe Encapsulated request(SCGCQ01013930)
 - MPI2.6: Fix defines that are not unique within the first 32 characters(SCGCQ01015826)
 - MPI 2.6: direct reporting of negotiated PCIe link width and speed(SCGCQ01017027)
 - MPI 2.6: Backend SRIS mode enable flag(SCGCQ01018687)
 - MPI2.6: Reserve ExtPageTypes for Dragon(SCGCQ01020473)
 - MR_CTRL_INFO expansion from 2K to 4K(SCGCQ01023741)
 - mega api changes for ibuttonless PR(SCGCQ01059740)
 - MPI2.6: Add x16 PCI support for Marlin family products(SCGCQ01063009)
 - MPI2.6: Fix PCI device page enclosure level/connector name to match SAS device page(SCGCQ01071374)
 - Profile Management Changes to support requestedProfileID and optimisedProfile(SCGCQ01075821)
 - MPI 2.6: Modify "SAS IO Unit Page 11" to add a new field "SATAHintingTimeout"(SCGCQ01092340)
 - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO(SCGCQ01094549)
 - MPI 2.6: Add Sea Arch class and Product IDs(SCGCQ01116837)
 - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file(SCGCQ01133839)
 - MPI2.6: Added new image type and flash region definitions(SCGCQ01136127)
 - MPI 2.6: Add new clean tool options(SCGCQ01141732)
 - MPI 2.6: Add two new reason codes to Active Cable Exception Event Data(SCGCQ01146583)
 - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register(SCGCQ01188725)
 - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile(SCGCQ01213092)
 - MPI2.6: Mfg7 support for arbitrary starting slot number(SCGCQ01213267)
 - MPI 2.6: Add new firmware download type (CBB BACKUP)(SCGCQ01258005)
 - MPI 2.5: Add additional EEDP Error Reporting capability to SCSI IO Reply(SCGCQ01002367)
 - MPI 2.5: Signed images for FWDownload(SCGCQ00469990)
 - MPI 2.5: Toolbox Console Text Display Tool(SCGCQ00415512)
 - Display the Storelib version in the show command.(SCGCQ01286063)
 - Unified StorCLI 7.1: PCIe Lane Speed and Link Configuration changes(SCGCQ01226457)
 - Unified StorCLI 7.1:OEL-Sparc support to Unified StorCLI(SCGCQ01196496)
 - Add support to allow Device names greater than 107(SCGCQ01039328)
 - Ventura : Add MR_ARRAY_EXT Support to StorCLI(SCGCQ01024636)
 - Enable SED on JBOD(SCGCQ00755527)
 - Allow VMWARE version of STORCLI cannot be run from any directory(SCGCQ00642230)
 - Added the OEM-NEC check for getting default disk-cache policy in Libmods as Disable.(SCGCQ00632051)
 - Request RAID CLI to display the Patrol Read Start Time(SCGCQ00564474)
 - Implemented the diag results to print on console(SCGCQ00525321)
 - MWCLI. R10, R50, R60, R00 VD creation(SCGCQ00369742)
 - MWCLI. Add HA support into storcli(SCGCQ00352120)
 - Create Spanned R0 array (00) in StorCLI(SCGCQ00350668)
 - Unified StorCLI 7.2:ARM-Linux support to Unified StorCLI(SCGCQ01241607)
 - Add NVMe device related changes(SCGCQ01034678)
 - Implemented the VD-VF mapping related commands in factory tool(SCGCQ00827665)
 - Complete 240VD support for utilities(SCGCQ00693042)
 - STORCLI will support MR controller management without UEFI BootServiceDriver Driver and also has retain functionality of existing seeadapter-through-driver functionality.(SCGCQ00621287)
 - dcmd path chagnes for supporting the new cachevault api(SCGCQ00381311)
 - Controller should not be reset after firmware download in CLI for SAS 3.5 Controllers(SCGCQ01399793)
 - Unified StorCLI 7.1:PPC Support(Big endian and Little endian) to Unified StorCLI(SCGCQ01196715)
 - Added the serial to properly log to the USB when the license is used for manufacturing the MFC on a controller.(SCGCQ01175821)
 - Unified CLI:Addition of appropriate device id's for Ventura(SCGCQ01132146)
 - LibMods: Increase maximum cache size for Cachecade to 2048GB. This will be named CC 2.5(SCGCQ00829204)
 - UDK Support for EFI(SCGCQ00795150)
 - Implemented the storcli command to print SATA drive's phy error counters and reset them.(SCGCQ00735171)
 - Consistent Sorting of Controllers for End Users in Customer Facing Tools(SCGCQ00696872)
 - Provide a way to enable or disable 512E using Applications(SCGCQ00351234)
 - Refer attached design doc(SCGCQ00349599)
 - Unified StorCLI : [Lenovo Purley] Adding tape drive support to Unified StorCLI for IT Ventura controllers.(SCGCQ01351495)
 - Unified StorCLI LibMods 7.1: Libmod changes for PCIe Lane Speed and Link Configuration(SCGCQ01227050)
 - Unified CLI changes to support host boot in MR with faulty FW(SCGCQ01093217)
 - Unified StorCLI:Implementing StoreLib IT static framework with StorCli(SCGCQ00916344)
 - LD Deletion stalling all IOs on Niwot HBA 12.12.0-0178(SCGCQ00757473)
 - RRB 71(SCGCQ00750164)
 - If any error that is returned as negative we return it s 0xFF from CLI to shell else FW returned error status will be returned to shell.(SCGCQ00665081)
 - SED/FDE changes for storcli Synchro(SCGCQ00632240)
 - ASD- StorCLI(SCGCQ00467863)
 - Implemented 128 drive support by using the new ENCL_INFO structures(SCGCQ00333209)
 - PERC 10 WIndows Support(SCGCQ01213160)
 - PERC 10 WIndows Support(SCGCQ01213157)
 - LibMods-Porting of MR6.x changes to Ventura(SCGCQ01109080)
 - Megacli/storcli support for lmrc driver(SCGCQ00433703)
 - PR SCGCQ00319011: Rebuild time reset(SCGCQ00381093)
 - Uneven span support is added in StorCLI.(SCGCQ00349548)
 - Unified StorCLI 7.1-Phase 2:IT Firmware downgrade support to Unified StorCLI(SCGCQ01224391)
 - Add EFI support for the manufacturing command to program.(SCGCQ01191095)
 - Ventura : Add IT Support to StorCLI [Checking in LIBMODS Changes ](SCGCQ00859216)
 - Storcli Should display SAS Address N/A if its invalid and change Host interface type names from PCIX, PCIE to PCI-X, PCI-E(SCGCQ00828476)
 - Monitoring Drive performance and predictive failure(SCGCQ00817977)
 - While saving and Restoring the configuration on controller we used to save MR_CONFIG_DATA and MR_CTRL_PROP. Added the below(SCGCQ01234118)
 - Unified StorCLI 7.1:FreeBSD OS support to Unified StorCLI 7.1(SCGCQ01191237)
 - LimMod changes related to CtrlH & MSM Mismatch on write-back options(SCGCQ00818987)
 - Functionality to extract field value from new API changes(SCGCQ00794841)
 - MR 4.12: Big endian architecture support for MR Linux driver and StorCli(SCGCQ00558815)


0007.0057.0000.0000 - Moderate Impact/Low Probability of Occurrence
-------------------
Enhancement:
- Added support for ThinkSystem HBA and RAID.

1.20.20 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where command "/cx show alilog d:/logfile=xyz.txt" reports success even when destination doesn't have enough space to save log file - (SCGCQ00861227)
- Fixed an issue where command "/c0/pall show" does not show Port number and whether the Port is valid - (SCGCQ00865335)
- Fixed an issue where command "/c0/epd0,1 show" doesn't report epd1 as invalid - (SCGCQ00908866)
- Fixed an issue where command "/c0 show bootdrive" doesn't display EPD for EPDs - (SCGCQ00918811)
- Fixed an issue where command "/c0/fall show" succeeds but "/c0/fall show all" fails- (SCGCQ0043074)
- Fixed an issue where command "/c1/e83 show status" may show "Unsupported" in many fields - (SCGCQ00950438)
- Fixed an issue where command "storcli /c0/d1 set transport=on sdhsp=on" uses a dedicated hotspare even though the command requests a shared hotspare - (SCGCQ00981663)
- Fixed an issue where an incorrect message may occur when creating a RAID5 - (SCGCQ00995140)
- Fixed an issue where command "/c0/cv start retentiontest" may result in an extra "File Write ERROR !!!" print - (SCGCQ00997401)
- Fixed an issue where an incorrect failure message may occur when creating a RAID1 with 3 drives - (SCGCQ00999258)
- Fixed an issue where Virtual Drive policy isn't retained after firmware flash fails - (SCGCQ01000358)
- Fixed an issue where storcli does not display description on command success - (SCGCQ01023973)
- Fixed an issue where "force" argument may not work with "parallel" argument - (SCGCQ01026081)
- Fixed an issue where command "/c0 show autoconfig" may result in empty values - (SCGCQ01026945)
- Fixed an issue where unable to set multipath parameter when firmware returns "MFI_STAT_OK_REBOOT_REQUIRED" - (SCGCQ01029534)
- Fixed an issue where command "/c0/eall/sall download src=H7280A520.P551 parallel" may report failure and success, when the flash has failed - (SCGCQ01030430)
- Fixed an issue where Mode 5 firmware download is not working with "parallel" argument - (SCGCQ01030535)
- Fixed an issue where storcli reports "Succeeded" instead of "Initiated" during a PD firmware flash status check - (SCGCQ01031218)
- Fixed an issue where storcli shows an incorrect error message when trying to remove the Blocked Access from SVDs - (SCGCQ01039102)
- Fixed an issue where storcli only shows firmware flash status for the last drive when multiple drives are being flashed simultaneously - (SCGCQ01039484)
- Fixed an issue where storcli does not give context-specific output for storcli help commands - (SCGCQ01039534)
- Fixed an issue where command "/c0 h" does not work - (SCGCQ01039745)
- Fixed an issue where command "/c0/cv start learn" may result in an incorrect message if the learn cycle fails - (SCGCQ01039757)
- Fixed an issue where Mode F is not fired after Mode E when "activatenow" is specified with no delay - (SCGCQ01052895)
- Fixed an issue where storcli did not disable offline commands and exit when Mode E or Mode F firmware download fails - (SCGCQ01053068)
- Fixed an issue where the entire error message is not shown when trying to update the security key "rekeyLock" - (SCGCQ01059105)
- Fixed an issue where JBOD status is shown under EPD column when displaying the status message - (SCGCQ01062314)
- Fixed an issue where "Segmentation fault" error may occur when creating and deleting multiple VDs in a loop - (SCGCQ01062646)
- Fixed an issue where an saving logs to an invalid destination does not cause an error - (SCGCQ01063899)
- Fixed an issue where JBOD information is displayed in EPD mode - (SCGCQ01064101)
- Fixed an issue where MFC_DEFAULTS are not handled correctly during VD creation - (SCGCQ01070120)
- Fixed an issue where "Failed operation not possible for current RAID level" error may occur when the error should have been "resources already in use" - (SCGCQ01073669)
- Fixed an issue where multi init parameter help syntax was missing - (SCGCQ01078997)
- Fixed an issue where storcli might crash when more than 200 characters are in the command - (SCGCQ01081082)
- Fixed an issue where extra prints and incorrect messages may occur while flashing PD firmware on SAS and SATA drives at the same time - (SCGCQ01091011)
- Fixed an issue where help did not include VFQDMode values and their explanations - (SCGCQ01128071)
- Fixed an issue where command "/c0/vall set pi=off" can error even though the command was successful - (SCGCQ01133117)
- Fixed an issue where output of show init/erase operation lists as VD instead of EPD - (SCGCQ00935416)
- Fixed an issue where multiple entries of the same object in a single command still results in success - (SCGCQ00947387)
- Fixed an issue where virtual drive may disappear after starting an erase on a RAID0 VD in simple and normal mode - (SCGCQ00995154)
- Fixed an issue where command "/c0/vall set hidden=on" or "/c0/vall set hidden=off" may error even on success - (SCGCQ01026907)
- Fixed an issue where "behavior" may appear as "behaviour" - (SCGCQ01029447)
- Fixed an issue where command "/c0 show events" errors even when successful - (SCGCQ01030139)
- Fixed an issue where storcli may ask for a system reboot if changing behavior from EPD to RAID0 - (SCGCQ01035493)
- Fixed an issue where storcli may not display "behavior mode" after setting the behavior mode - (SCGCQ01035500)
- Fixed an issue where command "/cx show preservedcache" may result in a "Segmentation fault" error when pinned cache is present - (SCGCQ01036028)
- Fixed an issue where command "/c0 show phyerrorcounters" shows success without printing the table - (SCGCQ01038669)
- Fixed an issue where MRI mode is taking any value and not reflecting - (SCGCQ01039536)
- Fixed an issue where command "/cx show alilog" calculates Leap Year incorrectly - (SCGCQ01039554)
- Fixed an issue where command "/c0/fall del" may not show correct error message when controller has pinned cache and is in Safe Mode  - (SCGCQ01043063)
- Fixed an issue where controller reset command was not blocked in EFI environment - (SCGCQ01052322)
- Fixed an issue where the copyright date showed 2015 instead of 2016 - (SCGCQ01053608)
- Fixed an issue where command "storcli /c0 /v0 start erase simple patterna=1" is not setting the pattern - (SCGCQ01057994)
- Fixed an issue where "/c0 set pcilinkspeed=3" command reports success even when the command isn't sent to firmware - (SCGCQ01058298)
- Fixed an issue where MFG data shows success when inputting an invalid file - (SCGCQ01058300)
- Fixed an issue where JBOD is being displayed when querying EPD information - (SCGCQ01059088)
- Fixed an issue where error "Snapshot is enabled on the Virtual Disk" may occur when creating and deleting multiple VDs in a loop - (SCGCQ01060805)
- Fixed an issue where "show BBMT" may show information for EPDs - (SCGCQ01064035)
- Fixed an issue where error "Invalid RAID level" may be shown instead of "Cannot create raid level with 1 span" - (SCGCQ01064084)
- Fixed an issue where SATA SSD firmware cannot be flashed - (SCGCQ01085706)
- Fixed an issue where storcli does not handle the return status properly during controller firmware flash - (SCGCQ01132613)
- Fixed an issue where command "storcli /c0/v1 start migrate type=raid1 option=add drives=120:5,7" may fail - (SCGCQ00879775)
- Fixed an issue where EPD-specific operations may not work - (SCGCQ00892973)
- Fixed an issue where delete EPD command may show Delete VD success message instead of Delete EPD success - (SCGCQ00905830)
- Fixed an issue where reboot required message may not occur when toggling SRIOV - (SCGCQ00919940)
- Fixed an issue where pinned cache of EPD may generates a listing as a Virtual Drive in the preserved cache message - (SCGCQ00988786)
- Fixed an issue where storcli may fail to set JBOD=off when there are no JBODs - (SCGCQ00993464)
- Fixed an issue where force flash may not work with resetnow opton - (SCGCQ00993466)
- Fixed an issue where storcli command for bbu may not read the SuperCap VPD information properly - (SCGCQ00994876)
- Fixed an issue where storcli may error "Resource already in use" when trying to configure RAID0 with online PDs - (SCGCQ01003415)
- Fixed an issue where storcli may not be able to change the behavior mode - (SCGCQ01023985)
- Fixed a typo in remaining time when issuing command "/cx/bbu show" - (SCGCQ01024968)
- Fixed an issue where printf may be seen in libmods in power-on-hours command - (SCGCQ01033027)
- Fixed an issue where storcli may not show an error when deleting security key fails - (SCGCQ01039756)
- Fixed an issue where "/c0/dall set" command may report success even though the command is incomplete - (SCGCQ01052306)
- Fixed an issue where command "/c0 dall show" may hang or throw an exception - (SCGCQ01052841)
- Fixed an issue where command "/c0 show" may display JBOD list when the behavior is set to EPD - (SCGCQ01052876)
- Fixed an issue where command "/c0 show memscribpatterns" status may report success but description says failed - (SCGCQ01058525)
- Fixed an issue where a "Synchronous Exception" may occur when running command "/c0 set vpd" with an incorrect input file - (SCGCQ01059798)
- Fixed an issue where storcli may throw an inappropriate error when trying to flash the wrong drive firmware to a drive - (SCGCQ01065620)
- Fixed an issue where drive firmware flash with parallel option may return error code 18 - (SCGCQ01066204)
- Fixed an issue where storcli may display Nytrocache even when controller does not support it - (SCGCQ01067274)
- Fixed an issue where storcli set JBOD as boot drive and removing JBOD as boot drive may display different messages - (SCGCQ01079667)
- Fixed an issue where connector name may not be sorted properly - (SCGCQ00890604)
- Fixed an issue where command "/c0/epd20 del" may not throw error when EPD is not present - (SCGCQ00904055)
- Fixed an issue where stop erase help file may show incorrect syntax - (SCGCQ00910533)
- Fixed an issue where host name and operating system details may show client machine instead of host machine - (SCGCQ00910614)
- Fixed an issue where storcli may misspell "controller" when flushing controller - (SCGCQ00973474)
- Fixed an issue where setting Consistency Check mode may fail if no start time given, and may set successfully if wrong time is given - (SCGCQ01039758)
- Fixed an issue where some commands may not report success on success - (SCGCQ01050695)
- Fixed an issue where storcli may show the wrong message when boot drive is cleared on all drives - (SCGCQ01053241)
- Fixed an issue where "/c0/vall show all" has an inaccurate description - (SCGCQ01058116)
- Fixed an issue where an extra space may appear in the message "Flash image is not supported , Try force." - (SCGCQ01064773)
- Fixed an issue where a SAS Address mismatch may occur after setting SAS Address from storclio - (SCGCQ01082500)
- Fixed an issue where storcli may show SDS reference and multiple modes for personality switch - (SCGCQ01127378)
- Fixed an issue where help output is not available for "/c0 add jbod h" - (SCGCQ01131493)
- Fixed an issue where command "/c0/epd4 del discardcache" may throw a syntax error - (SCGCQ00904205)
- Fixed an issue where error "Add EPD failed" may occur when creating an EPD - (SCGCQ00908864)
- Fixed an issue where Auto Config option MRIE-Mode may not be SMARTMODE - (SCGCQ00922540)
- Fixed an issue where EPD may not be allowed in JBOD mode - (SCGCQ01050766)
- Fixed an issue where the table may show EPD instead of JBOD - (SCGCQ01058178)
- Fixed an issue where error " segmentation fault " may occur - (SCGCQ01063305)
- Fixed an issue where command "set cc" may fail even though cc was set successfully - (SCGCQ01074482)
- Fixed an issue where installation of storclio may fail with syntax error - (SCGCQ01074514)
- Fixed an issue where a personality switch from JBOD to EPD may not clear JBOD and EPD config - (SCGCQ01080493)
- Fixed an issue where "delete preservedcache" option may not be listed in the help menu "/c0/vx delete h" - (SCGCQ00924642)
- Fixed an issue where storcli may crash when trying to attach a CacheCade Virtual Drive to source Virtual Drive. (SCGCQ00934528)
- Fixed an issue where there may be no error message for failure to initialize EPD - (SCGCQ00935477)
- Fixed an issue where installaton of storclio may fail - (SCGCQ00952422)
- Fixed an issue where references of epdpassthru were not JBOD - (SCGCQ01023981)
- Fixed an issue where command "/c0/vall show bbmt" may not display the corrected and uncorrected values - (SCGCQ01059790)
- Fixed an issue where command "/c0/vall set ssdcaching=on/off" may not apply to all the Virtual Drives - (SCGCQ01060315)
- Fixed an issue where command "/c0/delete config" output may not be consistent - (SCGCQ01091178)
- Fixed an issue where description of "add epd" may not state success or failure - (SCGCQ00908865)
- Fixed an issue where EPD details may not show in "show all" command  - (SCGCQ00921937)
- Fixed an issue where BIOS mode may not be able to be changed by storcli - (SCGCQ01058624)
- Fixed an issue where setting lowlatency to OFF, the multipath setting is changed to OFF as well - (SCGCQ01080489)
- Fixed an issue where storcli may crash when issuing command "/c0/vall show" - (SCGCQ00888330)
- Fixed an issue where drive microcode update to directly attached drives may fail in default mode - (SCGCQ00888837)
- Fixed an issue where command "/c0/vall del" may delete EPDs as well - (SCGCQ00915484)
- Fixed an issue where SRIOV may not be enabled by storcli - (SCGCQ00915697)
- Fixed an issue where storcli may continue to prompt even when force option is used for controller firmware flash - (SCGCQ01060461)
- Fixed an issue where connector name for first 8 PHYs of enclosure may not be displayed as expected - (SCGCQ00953464, Port of SCGCQ00890597)
- Fixed an issue where description status in failure message of EPD delete may not be accurate - (SCGCQ01015016, Port of SCGCQ00988760)
- Fixed an issue where factory defaults may not be aligned with the new API - (SCGCQ01044939, Port of SCGCQ01044891)
- Fixed an issue where phyerrorcounters command may not display any PHY Error Counter values - (SCGCQ01049064, Port of SCGCQ01028993)
- Fixed an issue where "show" command may fail - (SCGCQ01004630, SCGCQ01006038, Port of SCGCQ01004617)
- Fixed an issue where command "/call show logfile=filename" may result in error "segmentaton fault"  - (SCGCQ01020010, Port of SCGCQ01019547)
- Fixed an issue where command "/c0 show dequeuelog file=filename.txt" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01061120, Port of SCGCQ01014212)
- Fixed an issue where transport command may include "all" when only "shared" is requested - (SCGCQ01093159, Port of SCGCQ01093145)
- Fixed an issue where command "/c0 show alilog" may result in error "Segmentation fault(Core Dump)" - (SCGCQ01015017, Port of SCGCQ01014101)
- Fixed an issue where the hide and unhide options may not be available for a disk group - (SCGCQ01050234, Port of SCGCQ01050181)
- Fixed an issue where storcli may not generate a log - (SCGCQ00998150, Port of SCGCQ00945177)
- Fixed an issue where Global Hotspares may show as TR in disk group query - (SCGCQ01047957, Port of SCGCQ01047789)
- Fixed an issue where command "/bbu show all" may show "Remaining Time Alarm = Yes" even when not applicable  - (SCGCQ01143941, Port of SCGCQ01026187)
- Fixed an issue where maintainer name may not be populated when querying storcli version information from operating system - (SCGCQ00912697, Port of SCGCQ00838307)
- Fixed an issue where an invalid error message "Device is expander; use /c0/xp download" may be displayed on expander firmware download  - (SCGCQ01110108, Port of SCGCQ00934755)
- Fixed an issue where Virtual Drive number is not sorted in "/c0/vall show vfmap" command output - (SCGCQ00932799, Port of SCGCQ00929211)
- Fixed an issue where storcli may fail to correctly populate log files - (SCGCQ01079016, Port of SCGCQ01074584)

Enhancements:
- Added the personality change command was not present - (SCGCQ00850610)
- Extended the VFMaping to the max VFs suported by the adapter dynamically - (SCGCQ00868220)
- Added multipath support in EPD configuration options - (SCGCQ01015758)
- Added additional CPU support on EFI platform - (SCGCQ01026250)
- Added command to display progress of Patrol Read on a Physical Drive - (SCGCQ01040304)
- Added personality change features - (SCGCQ01111930)
- Added VF-queue depth mode settings - (SCGCQ00907072)
- Added ability to enable firmwre debug via storcli without UART - (SCGCQ00908320)
- Added Secure Erase support to JBOD and System drives - (SCGCQ00929757)
- Added a JBOD entity for various operations - (SCGCQ01047229)
- Added EPD support of setting EPD configuration parameter options - (SCGCQ00907064)
- Added more specific error messages in some circumstances - (SCGCQ00920034)
- Added new compilation environment and makefiles - (SCGCQ00920058)
- Added EPD and EPD-passthrough and single-drive RAID0 modes to eSDS - (SCGCQ01015739)
- Added support for drive microcode update Modes E and F - (SCGCQ01047223)
- Added code to display JBOD personality - (SCGCQ01146775)
- Updated existing implementaton to disable thermal polling in some circumstances - (SCGCQ01154338)
- Added new erase type called Crypto - (SCGCQ01050618)
- Added new command to set the multiInit EPD parameter - (SCGCQ01080273)
- Added support for drive microcode update through parallel loading - (SCGCQ01024964)
- Added support for EPD creation - (SCGCQ00887664)
- Modified a failure message to "This command only applies to Nytro Megaraid controllers. All others will display a failure status." - (SCGCQ01004610, Port of SCGCQ00881414)


1.18.11 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed issue where FW could be downleveled without using the noverchk flag (SCGCQ00924705)
- Fixed inaccurate message displayed while deleting a Cachecade Virtual Drive (CCVD) (SCGCQ00897785)
- Fixed issue where physical disk (PD) FW upgrade would fail with some SATA drives (SCGCQ00873612)
- Fixed issue where StorCLI failed to dump lastoneday pdfailevents in a file (SCGCQ00853196)
- Fixed issue where StorCLI was not reporting command success for a StorCLI64 /c0 show events file=eventLog.txt command (SCGCQ00851339)
- Fixed issue where StorCLI would not find enclosures in multipath environment (SCGCQ00873620)

Enhancements:
- Updated the BBU-properties in /c0/bbu show all (BBU learn mode) (SCGCQ00904662)
- Added the support to set and clear the transport on a DG (SCGCQ00920046)
- Added the support to change the large queue depth ctrl property in StorCLI (SCGCQ00933318)
- Implemented commands to save/restore the configuration on the controller. (SCGCQ00851795)
- Add support to detect that an OS is installed on a JBOD and to block it from being changed to Unconfigured Good (SCGCQ00828030)
- Provide a more descriptive port enumeration (SCGCQ00854620)
- Add support to enable/Disable of Large IO Support (SCGCQ00894644)

1.16.14 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no error message would occur when attempting to create a VD with Write-Back policy on a controller that does not support Write-Back - (SCGCQ00885617)
- Fixed an issue where StorCli would report "not in progress" for a rebuild instead of "paused" - (SCGCQ00907176)
- Fixed an issue where Foreign VD count of a spanned drive group is reported twice - (SCGCQ00911715)
- Fixed an issue where an invalid error "Device is expander,; use /c0/xp download" would occur when updating expander firmware - (SCGCQ00934755)

1.16.10 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Fixed an issue where no StorCLI error message is displayed when attempting to create a VD with WB policy on iMR HBA (SCGCQ00885617)
- Fixed an issue where controller status shown between MSM and StorCLI may contain false flash errors (SCGCQ00888470)
- Fixed an issue StorCLI PD firmware upgrade fails due to ATA Passthrough command being built incorrectly for download microcode (SCGCQ00862914)
- Fixed an issue StorCLI does not display E252/E253 enclosure info on an 84016 SCGCQ00868143)
- Corrected StorCLI behavior and messages between consecutive expansion operations of RAID Volume (SCGCQ00870429)
- Fixed an issue RAID level migration is not happening from 0 to level 1(SCGCQ00873770)


1.14.12 - Moderate Impact/Low Probability of Occurrence
-------
Fixes:
- Incorporated StorCLI MegaRAID 6.6 stream

Enhancements:
- Added ability to print SATA drives phy error counters and reset them (SCGCQ00735171)
- Added consistent sorting of controllers using bus, device, function (SCGCQ00696872)
- Added ability to enable or disable 512e support (SCGCQ00351234)
- Added support for Self-Encrypting Drives in JBOD mode (SCGCQ00755527)
- Added ability for VMWare version to be run from any directory (SCGCQ00642230)
- Added ability to display NCQ enabled/disabled status of every SATA drive (SCGCQ00564477)
- Added ability to create a RAID00 (SCGCQ00350668)
- Added ability to display the Patrol Read Start Time (SCGCQ00564474)
- Added learn cycle progress information in show learn command (SCGCQ00644984)
- Added support for uneven spans (SCGCQ00349548)
- Added support for lmrc driver (SCGCQ00433703)
- Added 240 Virtual Drive support (SCGCQ00693042)
- Improved Punctured Block logging (SCGCQ00342399) 

1.12.15 - Moderate Impact/Low Probability of Occurrence
-------
Fix(es):
 - Prevent storCLI from allowing users to enable JBOD mode on
   controllers that do not support JBOD mode.
 - Updated CACHEBYPASS command to line up with user expectation.  When CACHEBYPASS is set, the user wants the cache to be bypassed. In previous versions of storcli, setting CACHEBYPASS actually disables the bypass.

1.07.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M1215 SAS/SATA Controller
Fix(es):
 - Fixed an issue where segmentation faults may occur in Linux.
 - Added help information for resolving vd creation command fails with 'Memory Exhausted' message in SLES 11 OS.
 - Fixed an issue where estimated time left, which range from seven or more days for Consistency Check and rebuild operations, are not displaying.

1.04.07 - Moderate Impact/Low Probability of Occurrence
-------
Enhancement(s)
 - Added support for ServeRAID M5210e and ServeRAID M5210
Fix(es):
 - Fixed an issue where a command failure results in subsequent commands and actions failing.
 - Fixed an issue where storCLI reports a segmentation fault when running the command to downgrade the controller to iMR.
 - Added help file for for storcli /cx/dx set security
 - Fixed an issue where the "show ctrlcount help" command is not displaying properly.
 - Fixed an issue where a failure is displayed in the output for querying dimmer switch information.
 - Fixed an issue where the user is not able to set securitykey on a controller, if the securitykey was set through MSM.
 - Fixed an issue where the virtual drive creation command does not give any error message when the user tries to create a private information virtual drive using normal physical drives.
 - Fixed an issue where starkly displays a firmware flash successfully completed message even though the flashing failed.
 - Synced the pause pr command with show pr command to show correct PR Current State.
 - Fixed an issue where enabling online controller reset rate (OCR) from storCLI actually disables the controller property.

1.03.11 - Initial release
-------
Was this information helpful?

Your feedback helps to improve the overall experience

Alias Id: LNVGY_UTL_STOREHBA_MPT3.STORCLI-007.2205.0000.0000-0_WINDOWS_X86-64

Fix ID: lnvgy_utl_storehba_mpt3.storcli-007.2205.0000.0000-0_windows_x86-64

Release Date: 28 Mar 2023

Original Publish Date: 23 Dec 2022

Document ID: DS560131

Supported Search Keywords: Lenovo, Storage, Devices, Utility, storehba, Windows2019, Windows2022, HBA-430-x, AID:1D490203, FC:AUNN, PN:7Y37A01091, AID:1D490201, FC:AUNM, PN:7Y37A01089, AID:1D490202, FC:AUNR, PN:7Y37A01090, AID:1D490204, AID:1D490200, FC:AUNL, PN:7Y37A01088, HBA-440-x, AID:1D490206, PN:4Y37A78837, AID:1D490205, FC:B8P1, PN:4Y37A09725, AID:1D490207, AID:1D490208, AID:1D490209, PN:4Y37A09724
Feedback